Full-Service HVAC and Plumbing in Menifee Backed by Real Guarantees
When your home needs heating, cooling, or plumbing help, Cool Air Solutions delivers dependable service with no shortcuts and no surprises. From AC tune-ups and new furnace installations to water heater repairs and leak detection, we provide expert care for every comfort system in your home. Homeowners in Menifee count on us for fast, clean, and honest service, always backed by our unbeatable guarantees.
Need service now? Reach out online or call 951-234-0748 to schedule HVAC or plumbing in Menifee today.
Heating and Cooling Experts in Menifee
We handle all things HVAC with precision and care. Whether you're upgrading to a new energy-efficient AC or your furnace isn’t keeping up, our licensed technicians bring the right tools, the right attitude, and rock-solid craftsmanship to every visit.
- AC installation, repair, and maintenance
- High-efficiency furnace and electric furnace installation
- Ductless mini-splits and zoning systems
- Smart thermostat upgrades
- Seasonal system checkups
- Air balancing and airflow improvements
Every installation comes with our full lineup of guarantees—including our Lifetime Craftsmanship Guarantee, 1-Year Test Drive, No Lemon Guarantee, and No Surprise Pricing. And if your system breaks down unexpectedly, you’re covered by our 24-Hour Fix-It Guarantee—or we pay for your hotel stay.
Licensed Plumber in Menifee, CA
Got a leak, clog, or outdated water heater? Our expert plumbing team is ready to help. We specialize in clean, efficient repairs and system replacements that restore your water flow and peace of mind.
- Water heater repair and replacement (standard and tankless)
- Slab leak detection and pipe repair
- Faucet, shower, and toilet service
- Water softeners and filtration systems
- Pressure regulators and backflow prevention
- Garbage disposals, valves, and fixtures
- Camera inspections and sewer cleaning
Our plumbers show up on time, respect your home, and deliver top-tier results backed by our Lifetime Craftsmanship Guarantee—no cut corners, no compromises.
Affordable Options with Five-Star Results
Cool Air Solutions has earned more than 8,000 five-star reviews by putting homeowners first. We offer honest pricing, flexible financing, and a Comfort Club membership to keep your systems running strong year-round.
- Flat-rate pricing with no hidden fees
- Multiple financing options are available
- Exclusive rebates and energy incentives
- Maintenance plans for better performance and fewer breakdowns
- Licensed, insured, background-checked technicians
From energy-efficient upgrades to emergency repairs, you can count on us to get the job done right—and stand behind it.
Schedule Service in Menifee Today
Experience better comfort, better service, and unbeatable protection on every HVAC and plumbing job in Menifee. Use our online form or call 951-234-0748 to book your appointment now—we’ll be there when you need us.
Recent Jobs and Reviews in Menifee, CA
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and trust. Customers consistently praise the company for delivering professional, knowledgeable, and efficient service. A recurring theme is the technical expertise and personable nature of the technicians, who are described as respectful, friendly, and genuinely passionate about their work. Many reviewers highlight the quality of major installations, including complete HVAC system replacements and ductwork, noting impressive speed and precision even under challenging conditions. The company earns strong appreciation for their transparency, thorough documentation, and clear communication about necessary services versus optional ones. Long-term customer loyalty is evident, with clients expressing continued satisfaction over multiple years and repeated service calls. The responsiveness to inquiries and commitment to standing behind their work further reinforces the positive reputation. Overall, the tone is enthusiastic and grateful, with customers feeling valued and confident in the quality and reliability of the service provided.
Menifee, CA at a glance
Cool Air Solutions has completed 25 jobs in Menifee, CA between December 2020 and February 2021.
The most recent job was on February 2, 2021.
Cool Air Solutions has completed 17 jobs in Menifee, CA in the last 12 months. The first job there was in November 2016.
Our Local Reviews by City
- Aguanga, CA (5)
- Aliso Viejo, CA (1)
- Anaheim, CA (5)
- Banning, CA (2)
- Beaumont, CA (5)
- Bonsall, CA (9)
- Buena Park, CA (2)
- Canyon Lake, CA (27)
- Carlsbad, CA (59)
- Carson, CA (1)
- Cathedral City, CA (1)
- Chino, CA (2)
- Chino Hills, CA (4)
- Chula Vista, CA (13)
- Corona, CA (51)
- Del Mar, CA (3)
- Downey, CA (1)
- Eastvale, CA (1)
- El Cajon, CA (8)
- Encinitas, CA (5)
- Escondido, CA (119)
- Fallbrook, CA (65)
- Fontana, CA (2)
- Fountain Valley, CA (2)
- Fullerton, CA (2)
- Garden Grove, CA (5)
- Hacienda Heights, CA (1)
- Hemet, CA (73)
- Homeland, CA (9)
- Huntington Beach, CA (1)
- Irvine, CA (4)
- Jurupa Valley, CA (2)
- La Verne, CA (1)
- Ladera Ranch, CA (1)
- Laguna Hills, CA (5)
- Laguna Niguel, CA (2)
- Laguna Woods, CA (1)
- Lake Elsinore, CA (119)
- Lake Forest, CA (16)
- Lakeside, CA (5)
- Lakewood, CA (1)
- Lemon Grove, CA (1)
- Los Alamitos, CA (1)
- Menifee, CA (203)
- Mission Viejo, CA (8)
- Moreno Valley, CA (26)
- Murrieta, CA (670)
- Newport Beach, CA (1)
- Norco, CA (3)
- Nuevo, CA (2)
- Oceanside, CA (86)
- Ontario, CA (1)
- Pala, CA (1)
- Pauma Valley, CA (7)
- Perris, CA (24)
- Poway, CA (9)
- Ramona, CA (4)
- Rancho Cucamonga, CA (1)
- Rancho Santa Fe, CA (2)
- Rancho Santa Margarita, CA (2)
- Redlands, CA (4)
- Riverside, CA (36)
- San Bernardino, CA (4)
- San Clemente, CA (1)
- San Diego, CA (81)
- San Dimas, CA (1)
- San Jacinto, CA (28)
- San Juan Capistrano, CA (2)
- San Marcos, CA (48)
- Santa Ana, CA (3)
- Santa Fe Springs, CA (1)
- Solana Beach, CA (1)
- Spring Valley, CA (5)
- Sun City, CA (1)
- Temecula, CA (762)
- Temescal Valley, CA (1)
- Trabuco Canyon, CA (3)
- Upland, CA (2)
- Valley Center, CA (18)
- Vista, CA (161)
- Warner Springs, CA (5)
- Wildomar, CA (77)
- Winchester, CA (125)
- Yorba Linda, CA (14)
- Yucaipa, CA (5)
Job Locations and Reviews
Upon arrival performed routine maintenance. Indoor motors are both in good condition. Blower wheels are both starting to collect some dust on fins. Flame sensors on both systems have a lot of corrosion build up, this can cause systems to intermittently stop working. There is no distribution boxes on returns, returns are connected to side of furnace. Gas valve and shut offs in working order. Cleaned inside of furnace took out all insulation and dust from heating cabinet. Gas pressures good. - corroded flame sensors - standard filtration - dirty blower wheels - circuit board good - cleaned off furnaces Gonna follow up with client, gonna speak to wife about membership and upgraded filtration.
Replace existing system with listed equipment. Permits and HERS testing included 5% cash discount available (-$771) Cash discounts are only applied for check or cash only 36 Month 0% finance, $200 Lennox rebate And Free Air Scrubber plus Expires 2/5/2021
100% due upon completion Install 30x12 bar type return and seal return platform 3% cash discount available or 18 Months 0% interest financing or 6.9% with no prepayment penalties
Performed furnace maintenance on 2 4 year old Carrier furnaces. Cycled systems for heat. Verified proper heating sequence of operations. Temperature rise across heat exchangers is high but still within range. Ran systems through 20 point inspection checklists. Went over findings and recommendations with homeowner. Has an electrician buddy that might be able to take care of some of the work. Cycled systems, systems are operational upon departure.
Arrived on site to diagnose 2 2005 comfort makers that are not heating. Furnace located in attic. Client stated upstairs has been put for a year and downs that’s been out for 6 months. Home warranty came out due to a leak and never fix the leak. They left the pigtail unplugged for upstairs unit. Downs was operational then and found evaporator cover was never bolted shut. Inspected upstairs system. Found flame was not being produced as gas to produce flame. Advised client possibility control board is bad and gas valve is faulty. Advised client of findings and all other areas of concerns with system. Went over all summary of findings and areas of concerns and repairs and recommendations needed. Client is aware of why system is not heating. Advised client to consider full system replacement due the age, condition, r-22, refrigerant leak, and repairs and recommendations needed. Compared to full system replacement. Client is aware of what’s wrong with system and how they are running and
Performed furnace diagnostic on 1988 Carrier Heater. Upon my diagnostic client stated the system has been non-operational for at least one month. System is only making a clicking noise but no ignition. Further investigation showed that no pilot flame was active and the spark ignition was attempting to ignite. Found the gas valve has completely failed and is not Allowing gas to enter the pilot tube, Along with a weak spark ignition. Found evidence of condensation leakage due to a rotted evaporator coil primary pan, This had caused rust all within the indoor blower cabinet and alongside the furnace. Water leakage may have also caused damage to the spark ignition module overtime. Found that indoor blower motor was completely covered in dust and debris laying the back of the motor And with massive lubrication oil leakage from the bearing. Discuss the full condition Furnace with Jeff and notified him that any type of repairs that are done to the system will only be considered as a Band-Aid
Performed Furnace diagnostic a 90% aireflo Heater. Upon my diagnostic customer will stay that system was not firing up or heating at all and was very intermittent. Upon further investigation found That pressure switch was not closing due to clogged condensate and overfilled inducer motor due to rain water and condensation. Performed condensate clear and removed inducer motor draining all water. Work was complete and system is fully operational heating upon departure.
Performed heating maintenance on 13 year old furnace. Cycled system for heat. Verified proper heating sequence of operations. Temperature rise across heat exchanger is within range. Ran system through 20 point inspection checklist. Went over findings and recommendations with homeowner. Homeowner wants to go ahead and replace motor, but wants to do in in about a month or so. He will call us when he is ready to schedule to replace it. System is operational upon departure. Need to return and do filter drop off on front porch at anytime.
After Lennox rebate total $10,973.00
Arrived on site to perform diagnostic on a no heating on a 2005 Trane system. Furnace located in garage. Client wife stated just recently started noticing no warm air was coming out of system and only airflow was being produced and fan would stay running for a long period of time. Opened up electrical components to inspect connections and electrical. Cycled heater on. Found out flame was not being produced tripping safety mode and keeps fan motor running to get it self out of safety trip. Previous tech advised him flame sensor and igniter may fail in future due to there condition and age and igniter reading at a extremely high range of 168 ohms. Found flame sensors really oxidized and have carbon build up. Recommend replacing flame sensor and igniter to get system up and running for now and is minimum repairs needed. Tested igniter and checked voltage and igniter is getting 115v to ignite and is till not creating flame as it is bad now too. System then trip safety mode and keeps fan r
Upon arrival performed maintenance on lennox system. Dusted off all electrical components. Cleaned burners and adjusted back to place. Flame sensor was cleaned. Temp rise is in range. Replaced filter with merv 16 filter. Amperages on inducer draft motor and blower motor are good. Gas valve in working operations. Gas shut off good. Circuit board and electrical connections good. Venting is good. Saftey switches in furnace in working order. System was reset tested and fully functional upon departure.
Upon arrival performed maintenance on lennox system. Dusted off all electrical components. Cleaned burners and adjusted back to place. Flame sensor was cleaned. Temp rise is in range. Replaced filter with merv 16 filter. Amperages on inducer draft motor and blower motor are good. Gas valve in working operations. Gas shut off good. Circuit board and electrical connections good. Venting is good. Saftey switches in furnace in working order. System was reset tested and fully functional upon departure.
Upon arrival performed maintenance on lennox system. Dusted off all electrical components. Cleaned burners and adjusted back to place. Flame sensor was cleaned. Temp rise is in range. Replaced filter with merv 16 filter. Amperages on inducer draft motor and blower motor are good. Gas valve in working operations. Gas shut off good. Circuit board and electrical connections good. Venting is good. Saftey switches in furnace in working order. System was reset tested and fully functional upon departure.
Upon arrival performed maintenance on lennox system. Dusted off all electrical components. Cleaned burners and adjusted back to place. Flame sensor was cleaned. Temp rise is in range. Replaced filter with merv 16 filter. Amperages on inducer draft motor and blower motor are good. Gas valve in working operations. Gas shut off good. Circuit board and electrical connections good. Venting is good. Saftey switches in furnace in working order. System was reset tested and fully functional upon departure.
Replace both systems with listed equipment
Arrived on site to perform a heating tune up on a 2002 Goodman system. Furnace located in attic. Client stated he’s had a energy saving program company come out and had a nest thermostat replaced and a blower motor replaced as well. Since the. They have noticed a loud noise happening when system blower motor turns on and shuts off months later after it was all replaced. Advised the summary of findings are as followed. Goodman Furnace is original to home. Found filter to be dirty. Recommend replacing more often and as needed to reduce amount of dirt entering system. Blower assembly is really dirty and is creating more stress and wear on motor to work harder. Motor is good as it was replaced recently by Edison energy saving club. But who ever installed motor did not screw all the bolts from bracket holding motor and is moving around in assembly causing loud noise. Advised could be possibility of when they install motor could have stripped blower assembly cage and if so would have to r
Arrived on site to perform fall tune up on 2 2004 comfort maker. Client stated system are operational but not operating the best. Both furnace and evaporator coil located in attic. Advised the summary of findings are as followed. Found all filters dirty and black due to area surrounding home. Recommend replacing filters more often to reduce dirt entering system. Also creating restrictions of air flow causing system to over heat furnace. Found black flex ducting used on both systems in ok condition. Both systems only have 2 supply duct runs on each system. Both blower assembly are really dirty creating stress and wear on system. Recommend cleaning blower assembly to help reduce stress put on motors. Both Motor are both leaking from over working and heating up. Amp drawls are high from Working hard, possibility of motor failing In future due conditions and wear. Recommend replacing motors before completely fail. Found both secondary motor controls to be bad and weak and out of range fro
Performed heating maintenance on 2 14 year old York units. Cycled systems for heat. Verified proper heating sequence of operations. Ran systems through 20 point inspection checklists. Systems were fairly dirty and had rat droppings. Cleaned off both units exteriors as well as blower assemblies and heating compartments. Went over findings and recommendations with wife. Renewed 2 system yearly ESA maintenance program. Replaced 1 inch filters. Cycled system, System is operational upon departure.
Arrived on site to perform combo tuneup on a 2016 Lennox system. Furnace and Eva coil located in hall closet and condenser located outside of system in heating. Thermostat needed batteries And replaced. Found filter black and extremely dirty due to area surrounding home. Recommend replacing as needed and more frequently. Found black flex ducting used and ok condition. Blower assembly is light dust. Motor is good and amp deals are good. Inducer motor is is good and in range. Heat exchanger is good. Evaporator coil is good. Drain lines have some light dust accumulating. Tested drain pump and is good and draining. All safety switches are good. Temperature rise is good and in range. Found system receiving 122v and found no protection on either units. Recommend adding surge protectors to system to prevent from getting damaged from electrical surges and power outages that can damage or short out system and components. Recommend adding a phenomenal air as client due face yearly allergies. As
Arrived on site to perform heating tune up on a 1987 York system. System original to home. Furnace and evaporator coil located in hall closet. Client just moved in 2 years ago and wanted system system inspected. Advised client I would evaluate full system. advised the summary of findings are as followed. Attic 1. Found gray flex ducting used and original to home. 2. Found some duct runs to be under sized and reason why some rooms aren’t getting good air flow. 3. System only has 3 duct run only in use to full house. 4. Some areas in attic like living room don’t have enough insulation. Furnace 1. Found a 1987 York system up flow in closet. 2. Filter was extremely clogged as filter has never been replaced since he moved in. Recommend replacing every 3 months to reduce dirty from entering system. 3. Blower assembly is heavily dirty and building up. Creating stress and wear on motor. 4. motor has been leaking oil from over working and heating up. Motor has a thick layer of dirt
Diagnosed heating system for faults. Found loose molex plug on the circuit board causing system to flash open limit error code. Pushed the plug in and tested the system for operation. Temperature rise is a little high but not over the max. The circuit board continuously opens and closes the safety circuit, when the push pin is touched the circuit closes and then reopens continuously. The circuit board is bad and needs replaced.
Found loose connection on the high limit switch keeping the system from functioning. Tightened the connection and tested the system. System is working properly at this time.
Service maintenance for both heating systems. Tested all controls and motor components. Replaced filters. Recorded voltages and amp draws. Wiped down burner assembly and blower cabinets. Cleared condensate traps.
Arrived on site to perform heat maintenance on a 1980 system. System is located in hall closet. Client stated system works fine just wants to program his thermostat. Programs thermostat to client needs. Advised client I would evaluate full system. Advised the summary of findings are as followed. Furnace 1. 1980 furnace original to home. 2. Attic access was already broken in 2 piece and client is aware of existing damage to access door. 3.Found FS ducting used which is really old And made of insulated fiberglass which is not safe and healthy to breath in. 4. Filter was very dirt and was using hogHair filter And has no rack to hold filter down which allowing dirt to enter system from side of filter. 5. Blower assembly and wheel is very dirty and been accumulating over past years. Creating a lot of stress and wear on motor to work harder. Recommend blower assembly cleaning to help reduce wear and stress put on motor. 6. Motor is covered in oil and dirt build up as motor has been le
Quality control check