Expert HVAC Services in Pauma Valley, CA
Cool Air Solutions has been solving these problems since 2006 as we repair, replace and maintain the heating and cooling systems of your Pauma Valley CA neighbors. Nestled in the scenic beauty of Southern California, Pauma Valley is known for its warm climate, picturesque landscapes, and its rich agricultural heritage, including avocado and citrus orchards. Our team is committed to ensuring that your home remains a comfortable sanctuary, no matter the weather outside. Contact us today at (888) 659-2665 or visit our contact page to schedule your service and experience the Cool Air Solutions difference!
Our services are tailored to meet the unique needs of Pauma Valley residents, encompassing a broad range of HVAC solutions designed to enhance your indoor comfort and air quality. Here’s a closer look at what we offer:
Air Conditioning Services
- AC Installation and Replacement: Whether you need a new air conditioning system installed or an old one replaced, our certified technicians are equipped to handle the job with precision and care.
- AC Repair and Maintenance: From minor fixes to major repairs, we ensure your AC unit functions optimally. Regular maintenance helps in preventing breakdowns and extending the lifespan of your system.
- Ductless Mini-Splits: Ideal for homes without ductwork, our ductless mini-split systems provide efficient cooling solutions that can be installed in various zones of your home for targeted comfort
Heating Services
- Furnace Installation and Replacement: Keep your home warm during the cooler months with our efficient furnace installation and replacement services.
- Heating Repair and Maintenance: Our expert technicians offer reliable repair services and routine maintenance to ensure your heating system operates smoothly.
- Heat Pumps: As versatile systems that provide both heating and cooling, heat pumps are an excellent choice for year-round comfort.
Indoor Air Quality Solutions
- Air Filtration and Purification: Improve the air you breathe with our advanced air filtration and purification systems, which effectively remove contaminants and allergens from your home.
- Humidification and Dehumidification: Maintain optimal humidity levels in your home with our humidification and dehumidification services, ensuring a healthy and comfortable indoor environment.
Cool Air Solutions stands out for our commitment to customer satisfaction, quality service, and extensive experience. Our technicians are highly trained, ensuring that every job is done right the first time. We understand the importance of a reliable HVAC system and strive to provide services that enhance comfort and efficiency in your home.
Ready to experience top-quality HVAC services in Pauma Valley? Contact Cool Air Solutions today at (888) 659-2665 or visit our contact page to schedule an appointment!
Stay Comfortable Year-Round
Maintaining a comfortable home environment is crucial, especially in Pauma Valley’s diverse climate. Trust Cool Air Solutions to deliver the heating, cooling, and indoor air quality services you need. Whether it’s a scorching summer day or a chilly winter night, we’re here to ensure your home remains a haven of comfort.
Recent Jobs and Reviews in Pauma Valley, CA
Our Local Reviews by City
- Aguanga, CA (5)
- Aliso Viejo, CA (1)
- Anaheim, CA (5)
- Banning, CA (2)
- Beaumont, CA (5)
- Bonsall, CA (7)
- Buena Park, CA (2)
- Canyon Lake, CA (27)
- Carlsbad, CA (51)
- Carson, CA (1)
- Cathedral City, CA (1)
- Chino, CA (2)
- Chino Hills, CA (4)
- Chula Vista, CA (13)
- Corona, CA (49)
- Del Mar, CA (3)
- Downey, CA (1)
- Eastvale, CA (1)
- El Cajon, CA (8)
- Encinitas, CA (4)
- Escondido, CA (114)
- Fallbrook, CA (60)
- Fontana, CA (2)
- Fountain Valley, CA (2)
- Fullerton, CA (2)
- Garden Grove, CA (5)
- Hacienda Heights, CA (1)
- Hemet, CA (68)
- Homeland, CA (9)
- Huntington Beach, CA (1)
- Irvine, CA (4)
- Jurupa Valley, CA (2)
- La Verne, CA (1)
- Ladera Ranch, CA (1)
- Laguna Hills, CA (5)
- Laguna Niguel, CA (2)
- Laguna Woods, CA (1)
- Lake Elsinore, CA (113)
- Lake Forest, CA (14)
- Lakeside, CA (5)
- Lakewood, CA (1)
- Lemon Grove, CA (1)
- Los Alamitos, CA (1)
- Menifee, CA (194)
- Mission Viejo, CA (8)
- Moreno Valley, CA (26)
- Murrieta, CA (620)
- Newport Beach, CA (1)
- Norco, CA (3)
- Nuevo, CA (2)
- Oceanside, CA (83)
- Ontario, CA (1)
- Pala, CA (1)
- Pauma Valley, CA (7)
- Perris, CA (24)
- Poway, CA (9)
- Ramona, CA (4)
- Rancho Cucamonga, CA (1)
- Rancho Santa Fe, CA (2)
- Rancho Santa Margarita, CA (2)
- Redlands, CA (4)
- Riverside, CA (34)
- San Bernardino, CA (4)
- San Clemente, CA (1)
- San Diego, CA (76)
- San Dimas, CA (1)
- San Jacinto, CA (25)
- San Juan Capistrano, CA (1)
- San Marcos, CA (48)
- Santa Ana, CA (3)
- Santa Fe Springs, CA (1)
- Solana Beach, CA (1)
- Spring Valley, CA (5)
- Sun City, CA (1)
- Temecula, CA (725)
- Trabuco Canyon, CA (3)
- Upland, CA (2)
- Valley Center, CA (17)
- Vista, CA (147)
- Warner Springs, CA (5)
- Wildomar, CA (75)
- Winchester, CA (122)
- Yorba Linda, CA (12)
- Yucaipa, CA (5)
Job Locations and Reviews
Heating maintenance on Lennox air handler
When I arrived at home , I was told thermostat wouldn’t reach desired temperature. I set thermostat to cooling first and started diagnostic. I had power to air handler and thermostat communicating to air handler. I first checked motherboard for faulty error codes at air handler. Didn’t have any but the air handler was working efficiently. I quickly realized that the outdoor unit wasn’t on. I opened up the breaker panel and saw a tripped outdoor unit breaker. I turned breaker back on and went up to roof to service unit. I got two different error codes from outdoor system. I called tech support for assistance on how to resolve error codes. I had to check voltage at wires and check power at molex plugs. I replaced air filter because old one was caked with dirt and debris. This caused a restriction on whole system providing error codes. I reset the motherboard and reset the motherboard at the garage condenser head. Ran system in heating next to assure system is operational in both mo
Upon arrival performed maintenance on 2 Lennox heaters. Ducting is extremely undersized for systems. There are 2 ducts that go into a chase that is made of 2x4s and drywall. There is not a duct that falls down that chase to connect to a metal can . Both inducer draft motors are running extremely High in amperage’s. Circuit boards seem to be in good condtion. There is a lot of dirt and debree inside of systems, but client changed filters every year, advised we need to swap at least every 3 months due to these standard filters only doing 20 % of filtering. Only replaced 1 filter. Did not have 3 of the filters. The ducting system has no seals. Systems are operational. Closed everything back up. Reset & tested .
Upon arrival performed maintenance on 2 Lennox heaters. Ducting is extremely undersized for systems. There are 2 ducts that go into a chase that is made of 2x4s and drywall. There is not a duct that falls down that chase to connect to a metal can . Both inducer draft motors are running extremely High in amperage’s. Circuit boards seem to be in good condtion. There is a lot of dirt and debree inside of systems, but client changed filters every year, advised we need to swap at least every 3 months due to these standard filters only doing 20 % of filtering. Only replaced 1 filter. Did not have 3 of the filters. The ducting system has no seals. Systems are operational. Closed everything back up. Reset & tested .
Upon arrival performed maintenance on 2 Lennox heaters. Ducting is extremely undersized for systems. There are 2 ducts that go into a chase that is made of 2x4s and drywall. There is not a duct that falls down that chase to connect to a metal can . Both inducer draft motors are running extremely High in amperage’s. Circuit boards seem to be in good condtion. There is a lot of dirt and debree inside of systems, but client changed filters every year, advised we need to swap at least every 3 months due to these standard filters only doing 20 % of filtering. Only replaced 1 filter. Did not have 3 of the filters. The ducting system has no seals. Systems are operational. Closed everything back up. Reset & tested .
Upon arrival performed maintenance on 2 Lennox heaters. Ducting is extremely undersized for systems. There are 2 ducts that go into a chase that is made of 2x4s and drywall. There is not a duct that falls down that chase to connect to a metal can . Both inducer draft motors are running extremely High in amperage’s. Circuit boards seem to be in good condtion. There is a lot of dirt and debree inside of systems, but client changed filters every year, advised we need to swap at least every 3 months due to these standard filters only doing 20 % of filtering. Only replaced 1 filter. Did not have 3 of the filters. The ducting system has no seals. Systems are operational. Closed everything back up. Reset & tested .
Performed heating maintenance on 2 year old Lennox air handler. Return grate is clean. Cleaned condensate drain P trap and flushed with water. Removed large amount of sawdust from unit and surrounding area. Tested electrical draw of blower and electrical heat strips. Inspected blower compartment, blower wheel is clean and balanced. Temperature rise is normal. Noticed that the unit only has two 12†returns which give it 1000 cfm of return, this is a 5 ton unit and should have 2000 cfm of airflow, because of this the static pressure was high. Surge protection was recommended for the air handler. Upon departure system is operational.
Upon arrival system was operational. Client informed me that he reset the breaker and the unit came on. Changed out the filter and did a preventive drain flush. Unit is operational upon departure.
Upon arrival performed refrigerant diagnostic. System was low on charge. Advised to look for leak, actual home owner doesn’t wNt to, said charge it so tenants can have cool air. They have to recharge every single year. System is charged with 6 lbs of refrigerant.
Upon arrival performed refrigerant diagnostic. System was low on charge. Advised to look for leak, actual home owner doesn’t wNt to, said charge it so tenants can have cool air. They have to recharge every single year. System is charged with 6 lbs of refrigerant.
Upon arrival performed refrigerant diagnostic. System was low on charge. Advised to look for leak, actual home owner doesn’t wNt to, said charge it so tenants can have cool air. They have to recharge every single year. System is charged with 6 lbs of refrigerant.
Upon arrival performed refrigerant diagnostic. System was low on charge. Advised to look for leak, actual home owner doesn’t wNt to, said charge it so tenants can have cool air. They have to recharge every single year. System is charged with 6 lbs of refrigerant.
Upon arrival cleaned out both condenser coils. Checked electrical motors. All operational. Components are older and should be replaced. System is using a lot of power. Flushed drain lines and changed out filters. Client did not want any repair recommendations. Found several components at risk of failing. System are operational upon departure.
Replaced blower motor control module under warranty. Installed new S30 ultra thermostat. Tested equipment, reset purifier data, raised auxiliary heat activation thresholds to keep the heat strips from operating regularly. Connected the iPhone to the thermostat and deleted old thermostat.
Lennox heat pump cooling maintenance. Tested equipment and mini operation. Recorded system electrical values. Replaced filter. Reset filter pure air gauge. Recorded temperatures. Tightened connections.
Upon arrival found 2 systems to do tune ups on. Master bedroom heater was first. Unit is resting on isolation pads with little clearance to floor. Flood protection was weak. Temp rise was almost at max. Inspected heat exchanger. Did not find any cracks however lots of hot spots in failure areas. Advised client. Kitchen unit was better with some flood protection. Temp rise was good. Ignition components are okay for its age. Unit is operational upon departure.
Arrived on site to install 2 pole 50 amp breaker that had failed last time out. Client is aware was a weak breaker as we did not replace. Replaced and installed new breaker and cycled system in heating to ensure system operating. Both surge protectors were good and operational. Client is aware unit is running and good now and happy we came out today. System is operational upon departure.
Arrived on site to perform combo tune up on a 2020 lennox unit. Condenser located on roof. Furnace and indoor coil located in attic. Cycled both heating and cooling. cleaned coil inside and out. Checked all electrical compartment and components. All were good. Start up and run amps are good. Checked pressure and are good and operational. Unit is cooling home good. No protection on unit. Recommended adding protection on unit. Inspected indoor unit and filter was dirty. Client purchased wrong filter but was wrong size. Blower assembly is good. Motor is good. Unit is heating up home good. Cycled unit and went over all findings and client wanted to go forward with adding surge protectors to units. Client installed and outside was good. Indoor unit breaker found out breaker in attic failed. Tested and breaker fail overall and needs to be replaced. Client would like to do so and would to do soo and get him back on the schedule. Client is aware and would get him back on schedule. Client is
Technician arrived on site. Customer has 2 systems. Maintenance is only for 1. Did the north side unit. Temp split and charge are off. Compressor amps are okay. Nothing over amping at this time. Fan motor is close. Cap is almost failing. Recommend replacing the cap and fan motor before they fail.
Performed three system Rheem furnace maintenance. Client stated that they are in the process of selling the home. During the maintenance I came across a few points and concerns that were addressed with Mr. Cooper. Furnace 1- 1. Found an indoor blower motor had significant oil leakage coming from bearing this can cause the motor to overheat or lock up. 2. Single secondary motor control has become week due to indoor blower motor using more power than needing ultimately draining this component 3. Indoor blower Cabinet is heavily covered in dust and debris due to 1 inch filters inefficiently stopping dust particles. recommended these filters a swapped out every one to three months 4. Secondary drain pan did not contain a safety Killswitch in the case of the condensation lines ever clogging, this would be preventing a flood over on to the ceiling. 5. Flame sensor was oxidized and had carbon buildup 6. Static pressure on system was very high this is due to the multiple zones 7. System was n
Arrived on site to perform furnace maintenance on 23 year old Lennox furnace. Cycled system for heat. Verified proper heating sequence of operations. Temperature rise across heat exchanger is within range. Ran system through 20 point inspection checklist. Cleaned heating and blower compartment. Wiped down the exterior of the furnace. Went over findings and recommendations with homeowner. Spoke on the topic of system replacement, homeowner currently does not want to put any money into the existing units and is waiting to be ready form replacement. Discussed different type of system options and which one would be most effective for the home and how they use it. Current systems are just single stage units with 2 zones, which is not ideal. Cycled system, system is operational upon departure.
Performed maintenance on 23 year old Lennox furnace. Furnace is single stage unit with 2 zones. We are only servicing the unit above the right hand side closet next to the office. Does not want other unit serviced. Cycled system for heat. Verified proper heating sequence of operations. Temperature rise across heat exchanger is in range when both zones are activated, but is slightly high whenever one zoned is closed. Amp draws on indoor blower motor are high but within range. Secondary motor control was recently replaced and is in range. Blower wheel is slightly dirty. Checked heating components. Cleaned flame sensor. Cleaned blower assembly and heating compartment. Also wiped down unit exterior. Flushed out condensation lines with cartridge. Replaced 1 inch filters. Pulled blower assembly and inspected heat exchanger. Heat exchanger doe have some hot spots, but Areas of concern were inspected and all checked good as of now. Homeowner has 1 visit left for cooling. Cycled system, system
Upon arrival spoke to client, we opened up system together found system completely dirty. Client wanted to do cleanings. Did a quick visual check with smaller parts and has a lot of failing parts inside of condenser. Also pointed out that she is paying over thousands in 2 months of bills for electrical, home does not cool efficient. Wants to go over replacement options. Office to set up appointment
Upon arrival spoke to client, we opened up system together found system completely dirty. Client wanted to do cleanings. Did a quick visual check with smaller parts and has a lot of failing parts inside of condenser. Also pointed out that she is paying over thousands in 2 months of bills for electrical, home does not cool efficient. Wants to go over replacement options. Office to set up appointment