Full-Service HVAC and Plumbing in Menifee Backed by Real Guarantees
When your home needs heating, cooling, or plumbing help, Cool Air Solutions delivers dependable service with no shortcuts and no surprises. From AC tune-ups and new furnace installations to water heater repairs and leak detection, we provide expert care for every comfort system in your home. Homeowners in Menifee count on us for fast, clean, and honest service, always backed by our unbeatable guarantees.
Need service now? Reach out online or call 951-234-0748 to schedule HVAC or plumbing in Menifee today.
Heating and Cooling Experts in Menifee
We handle all things HVAC with precision and care. Whether you're upgrading to a new energy-efficient AC or your furnace isn’t keeping up, our licensed technicians bring the right tools, the right attitude, and rock-solid craftsmanship to every visit.
- AC installation, repair, and maintenance
- High-efficiency furnace and electric furnace installation
- Ductless mini-splits and zoning systems
- Smart thermostat upgrades
- Seasonal system checkups
- Air balancing and airflow improvements
Every installation comes with our full lineup of guarantees—including our Lifetime Craftsmanship Guarantee, 1-Year Test Drive, No Lemon Guarantee, and No Surprise Pricing. And if your system breaks down unexpectedly, you’re covered by our 24-Hour Fix-It Guarantee—or we pay for your hotel stay.
Licensed Plumber in Menifee, CA
Got a leak, clog, or outdated water heater? Our expert plumbing team is ready to help. We specialize in clean, efficient repairs and system replacements that restore your water flow and peace of mind.
- Water heater repair and replacement (standard and tankless)
- Slab leak detection and pipe repair
- Faucet, shower, and toilet service
- Water softeners and filtration systems
- Pressure regulators and backflow prevention
- Garbage disposals, valves, and fixtures
- Camera inspections and sewer cleaning
Our plumbers show up on time, respect your home, and deliver top-tier results backed by our Lifetime Craftsmanship Guarantee—no cut corners, no compromises.
Affordable Options with Five-Star Results
Cool Air Solutions has earned more than 8,000 five-star reviews by putting homeowners first. We offer honest pricing, flexible financing, and a Comfort Club membership to keep your systems running strong year-round.
- Flat-rate pricing with no hidden fees
- Multiple financing options are available
- Exclusive rebates and energy incentives
- Maintenance plans for better performance and fewer breakdowns
- Licensed, insured, background-checked technicians
From energy-efficient upgrades to emergency repairs, you can count on us to get the job done right—and stand behind it.
Schedule Service in Menifee Today
Experience better comfort, better service, and unbeatable protection on every HVAC and plumbing job in Menifee. Use our online form or call 951-234-0748 to book your appointment now—we’ll be there when you need us.
Recent Jobs and Reviews in Menifee, CA
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and trust. Customers consistently praise the company for delivering professional, knowledgeable, and efficient service. A recurring theme is the technical expertise and personable nature of the technicians, who are described as respectful, friendly, and genuinely passionate about their work. Many reviewers highlight the quality of major installations, including complete HVAC system replacements and ductwork, noting impressive speed and precision even under challenging conditions. The company earns strong appreciation for their transparency, thorough documentation, and clear communication about necessary services versus optional ones. Long-term customer loyalty is evident, with clients expressing continued satisfaction over multiple years and repeated service calls. The responsiveness to inquiries and commitment to standing behind their work further reinforces the positive reputation. Overall, the tone is enthusiastic and grateful, with customers feeling valued and confident in the quality and reliability of the service provided.
Menifee, CA at a glance
Cool Air Solutions has completed 25 jobs in Menifee, CA between February 2021 and March 2021.
The most recent job was on March 1, 2021.
Cool Air Solutions has completed 17 jobs in Menifee, CA in the last 12 months. The first job there was in November 2016.
Our Local Reviews by City
- Aguanga, CA (5)
- Aliso Viejo, CA (1)
- Anaheim, CA (5)
- Banning, CA (2)
- Beaumont, CA (5)
- Bonsall, CA (9)
- Buena Park, CA (2)
- Canyon Lake, CA (27)
- Carlsbad, CA (59)
- Carson, CA (1)
- Cathedral City, CA (1)
- Chino, CA (2)
- Chino Hills, CA (4)
- Chula Vista, CA (13)
- Corona, CA (51)
- Del Mar, CA (3)
- Downey, CA (1)
- Eastvale, CA (1)
- El Cajon, CA (8)
- Encinitas, CA (5)
- Escondido, CA (119)
- Fallbrook, CA (65)
- Fontana, CA (2)
- Fountain Valley, CA (2)
- Fullerton, CA (2)
- Garden Grove, CA (5)
- Hacienda Heights, CA (1)
- Hemet, CA (73)
- Homeland, CA (9)
- Huntington Beach, CA (1)
- Irvine, CA (4)
- Jurupa Valley, CA (2)
- La Verne, CA (1)
- Ladera Ranch, CA (1)
- Laguna Hills, CA (5)
- Laguna Niguel, CA (2)
- Laguna Woods, CA (1)
- Lake Elsinore, CA (119)
- Lake Forest, CA (16)
- Lakeside, CA (5)
- Lakewood, CA (1)
- Lemon Grove, CA (1)
- Los Alamitos, CA (1)
- Menifee, CA (203)
- Mission Viejo, CA (8)
- Moreno Valley, CA (26)
- Murrieta, CA (670)
- Newport Beach, CA (1)
- Norco, CA (3)
- Nuevo, CA (2)
- Oceanside, CA (86)
- Ontario, CA (1)
- Pala, CA (1)
- Pauma Valley, CA (7)
- Perris, CA (24)
- Poway, CA (9)
- Ramona, CA (4)
- Rancho Cucamonga, CA (1)
- Rancho Santa Fe, CA (2)
- Rancho Santa Margarita, CA (2)
- Redlands, CA (4)
- Riverside, CA (36)
- San Bernardino, CA (4)
- San Clemente, CA (1)
- San Diego, CA (81)
- San Dimas, CA (1)
- San Jacinto, CA (28)
- San Juan Capistrano, CA (2)
- San Marcos, CA (48)
- Santa Ana, CA (3)
- Santa Fe Springs, CA (1)
- Solana Beach, CA (1)
- Spring Valley, CA (5)
- Sun City, CA (1)
- Temecula, CA (762)
- Temescal Valley, CA (1)
- Trabuco Canyon, CA (3)
- Upland, CA (2)
- Valley Center, CA (18)
- Vista, CA (161)
- Warner Springs, CA (5)
- Wildomar, CA (77)
- Winchester, CA (125)
- Yorba Linda, CA (14)
- Yucaipa, CA (5)
Job Locations and Reviews
Preformed furnace maintenance on 2006 Lennox heater. Need to return and install 6 dampers on supply runs of ductboard coil to increase air flow to front bedroom.
Returned to perform repairs. Pulled out existing motor. Replaced with new OEM motor. Made sure everything was tight. Ensured all connections were tight. Cycled system through modes. System is fully operational upon departure.
Installed outdoor fan motor and duel secondary motor warranty for 1 year on components
Installed outdoor fan motor and duel battery cap 1 year warranty on parts
Performed AC/furnace tuneup on 2003 Aireflo System. Upon my maintenance there were multiple points of concerns that were addressed with the homeowner. AC- 1. Found the condenser fan motor Leaking oil from bearing due Lubricant seal rupturing. This can cause the motor to pull hire Amperage along with it locking up or overheating From lack of lubrication. If this component fails this can cause compressor to overheat and create much more damage than what has already has occurred. 2. Duel secondary motor control has become weak on the hermetic and fans side terminals. 3. High-voltage relay contained putting on contact points. This completed access the brakes for the system and can cause failure on start up and shut down if pitting worsens. 4. Measured compressor amperage and found a total of 15 A being pulled which is fairly high considering that there is no heat load in the house and the ambient temperature is very low today. 5. Condenser fan motor Amperage was also exceeding manufactur
Performed AC/furnace maintenance A 1994 comfort maker system. This is the rental property of John Peterson. During the maintenance we also came across a few points of concerns that were addressed with John. AC- 1. Found the condenser fan motor had a oil leakage Coming from Lubricant seal of bearing. This can ultimately lead to the motor locking up or overheating due to lack of lubrication around bearing. 2. Duel secondary motor control has become weak and compressor side terminal. 3. Compressor pulling 10 A coming very close to the manufacture specification of 13 A 4. High voltage relay also contained high amount of pitting on contact points due to compressor using high amperage overtime this was eventually completely eat away at the brakes of the system. 5. System also contains R22 refrigerant which was completely phased out January 1, 2020 Furnace- 1. Inspected the heat exchanger and found no signs of cracks on eyelids. 2. Found an indoor blower motor was completely covered in du
Training visit
Will be returning to sync new Lennox remote with mini split due to previous one being lost. Also confirmed that Heater is running properly and is our install from 2020. System had a 53° temperature rise with 125° coming out. Due to heat rising, downstairs will feel a bit colder versus upstairs having much more heat build up. Recommended that filter swapped out as well. Signed client up ESA maintenance And will be returning with new remote once part is in. Upon departure system is fully operational and Heating home at this time.
Upon arrival performed maintenance, indoor motor is in good condition. Indoor blower wheel is very dusty and has dust on fins. This causes off balance on blower wheel and weight on motor. Circuit board and electrical connections good. Gas piping does not has 3 inch sediment trap. Client would like to cancel membership, due to filter having to be charged for. Client was Just upset. Client said she never seen the benefit of membership if we aren’t including filters. Flame sensor has a lot of oxide build. Gas valve in working order. System was reset tested and fully functional
Upon arrival performed maintenance, indoor motor is in good condition. Indoor blower wheel is very dusty and has dust on fins. This causes off balance on blower wheel and weight on motor. Circuit board and electrical connections good. Gas piping does not has 3 inch sediment trap. Client would like to cancel membership, due to filter having to be charged for. Client was Just upset. Client said she never seen the benefit of membership if we aren’t including filters. Flame sensor has a lot of oxide build. Gas valve in working order. System was reset tested and fully functional
Upon arrival performed maintenance, indoor motor is in good condition. Indoor blower wheel is very dusty and has dust on fins. This causes off balance on blower wheel and weight on motor. Circuit board and electrical connections good. Gas piping does not has 3 inch sediment trap. Client would like to cancel membership, due to filter having to be charged for. Client was Just upset. Client said she never seen the benefit of membership if we aren’t including filters. Flame sensor has a lot of oxide build. Gas valve in working order. System was reset tested and fully functional
Upon arrival performed maintenance, indoor motor is in good condition. Indoor blower wheel is very dusty and has dust on fins. This causes off balance on blower wheel and weight on motor. Circuit board and electrical connections good. Gas piping does not has 3 inch sediment trap. Client would like to cancel membership, due to filter having to be charged for. Client was Just upset. Client said she never seen the benefit of membership if we aren’t including filters. Flame sensor has a lot of oxide build. Gas valve in working order. System was reset tested and fully functional
Arrived on site to perform fall tun up on a 2014 carrier system. Client stated no issues. Cycled both thermostat and are good. Found all filter dirty and over due replacement. Recommend replacing more often are as needed to prevent air flow restrictions and dirt entering system. Blower assembly and wheel are getting dirty and accumulating dirt and debris. Recommend cleaning blower assembly to reducer wear on motor. System has 2 zones on a single stage system. Advised would want variable speed system to help improve airflow all around home and less stress on motor. Secondary motor control is good. Flames sensor slight wear. Igniter is good and in range. Found inducer motor with a lot of play on wheel and is pulling almost max amps. Wheel of inducer is getting unbalanced and can cause inducer motor to fail sooner then expected to wear its self caused. Heat exchanger is good. Drain lines are dirt and accumulating debris in system. Advised secondary line is dripping straight into emergenc
Installation of a Lennox Single Stage 16 SEER A/C with High Performance Coil and Single Stage Ultra Low NOx Furnace, including UV Light and upgraded Filtration
Collected 1050. Balance due of 19873 paid by service finance
Upon arrival performed maintenance on 2005 comfort maker. Cleaned and dusted indoor cabinet and outdoor of furnace. Gas valve and shut off in working order. Disassembled burners and cleaned all dust inside. Circuit board and electrical connections good. Evap coil is dirty, recommend cleanings and swapping filters out more frequently. Inducer draft motor running close to high amperages. Examined heat exchanger, lots of hot spots and corrosion. Checked for any damaged parts of heat exchanger, did not verify any cracks. Temp rise splits in range. - dirty blower wheel - dirty evaporator coil - dusted all electrical components - cleaned and sanitized indoor caging Disassembled burners and dusted off System was reset tested and fully functional upon departure.
Upon arrival performed maintenance on 2005 comfort maker. Cleaned and dusted indoor cabinet and outdoor of furnace. Gas valve and shut off in working order. Disassembled burners and cleaned all dust inside. Circuit board and electrical connections good. Evap coil is dirty, recommend cleanings and swapping filters out more frequently. Inducer draft motor running close to high amperages. Examined heat exchanger, lots of hot spots and corrosion. Checked for any damaged parts of heat exchanger, did not verify any cracks. Temp rise splits in range. - dirty blower wheel - dirty evaporator coil - dusted all electrical components - cleaned and sanitized indoor caging Disassembled burners and dusted off System was reset tested and fully functional upon departure.
Upon arrival performed maintenance on 2005 comfort maker. Cleaned and dusted indoor cabinet and outdoor of furnace. Gas valve and shut off in working order. Disassembled burners and cleaned all dust inside. Circuit board and electrical connections good. Evap coil is dirty, recommend cleanings and swapping filters out more frequently. Inducer draft motor running close to high amperages. Examined heat exchanger, lots of hot spots and corrosion. Checked for any damaged parts of heat exchanger, did not verify any cracks. Temp rise splits in range. - dirty blower wheel - dirty evaporator coil - dusted all electrical components - cleaned and sanitized indoor caging Disassembled burners and dusted off System was reset tested and fully functional upon departure.
Upon arrival performed maintenance on 2005 comfort maker. Cleaned and dusted indoor cabinet and outdoor of furnace. Gas valve and shut off in working order. Disassembled burners and cleaned all dust inside. Circuit board and electrical connections good. Evap coil is dirty, recommend cleanings and swapping filters out more frequently. Inducer draft motor running close to high amperages. Examined heat exchanger, lots of hot spots and corrosion. Checked for any damaged parts of heat exchanger, did not verify any cracks. Temp rise splits in range. - dirty blower wheel - dirty evaporator coil - dusted all electrical components - cleaned and sanitized indoor caging Disassembled burners and dusted off System was reset tested and fully functional upon departure.
Arrived on site to diagnose a no heating system on a 2006 aireflow. Client stated system has been down for a couple years. Advised client i would inspect system of issues and see what’s going on. Inspected all electrical compartment and found system giving error code of bad polarity and found pig outlet bad as it wasn’t send proper voltage to system to operate properly. Also found something stuck and broken in side the outlet as well. Advised we got system operational and ran system for a bit and shortly after had all smoke detectors and carbon monoxide detectors all go off in home and we shut system down. Advised client of finds and we would do a safety evaluation of the system to ensure system would be safe to run. Pulled heat exchanger out and found system was leaking and heat exchanger is now compromised and no longer safe to run and we would have to shut gas off to system for safety reason as compromised heat exchanger is not safe for anyone in home and could risk allowing com
Arrived on site to perform fall tune up on a 2003 carrier unit. Furnace located in attic. Client stated no issues just wanted system serviced. Cycled thermostat on and was good. Found filter to be washable and good. Found black flex ducting used and old condition. Found blower assembly really dirty due to the amount of dirt that has entered system is past years and creating stress on motor.recommend cleaning blower assembly to help reduce wear and stress on motor. Motor is now leaking oil as there is oil down shaft of motor and in blower wheel it self. Motor is pulling high amp draws and almost at max and could be failing at any time. Recommend replacing motor before completely fails. Inducer motor is over amping as it’s pulling 1.7 amps and max rated at 1.4 amps. Indicating inducer motor could fail at any time due to age and how hard it’s working. Secondary motor control is weak and bad from blower motor working hard draining life of unit. Inspected and pulled heat exchanger and
Performed furnace maintenance on 7 year old trane system. Cycled system for heating. Verified proper heating sequence of operations. Temperature rise across heat exchanger is within range. Replaced 1 inch filters. Ran system through 20 point inspection checklist. Went over findings and recommendations with homeowner. Homeowner mentioned that she has a couple rooms with airflow problems that she would like to get fixed. Spoke about doing some minor tweaks to the existing ducting, or replacing all the ducting altogether. Homeowner ultimately wants to replace the ductwork. Gave her a approx estimate to get ducting replaced. Would need to get a specialist out to properly size ducting. Homeowner has to get her schedule coordinated as she does not live on the property year round. She will give us a call when ready. Cycled system, system is operational upon departure.
Upon arrival performed routine maintenance. Indoor motors are both in good condition. Blower wheels are both starting to collect some dust on fins. Flame sensors on both systems have a lot of corrosion build up, this can cause systems to intermittently stop working. There is no distribution boxes on returns, returns are connected to side of furnace. Gas valve and shut offs in working order. Cleaned inside of furnace took out all insulation and dust from heating cabinet. Gas pressures good. - corroded flame sensors - standard filtration - dirty blower wheels - circuit board good - cleaned off furnaces Gonna follow up with client, gonna speak to wife about membership and upgraded filtration.
Upon arrival performed routine maintenance. Indoor motors are both in good condition. Blower wheels are both starting to collect some dust on fins. Flame sensors on both systems have a lot of corrosion build up, this can cause systems to intermittently stop working. There is no distribution boxes on returns, returns are connected to side of furnace. Gas valve and shut offs in working order. Cleaned inside of furnace took out all insulation and dust from heating cabinet. Gas pressures good. - corroded flame sensors - standard filtration - dirty blower wheels - circuit board good - cleaned off furnaces Gonna follow up with client, gonna speak to wife about membership and upgraded filtration.
Upon arrival performed routine maintenance. Indoor motors are both in good condition. Blower wheels are both starting to collect some dust on fins. Flame sensors on both systems have a lot of corrosion build up, this can cause systems to intermittently stop working. There is no distribution boxes on returns, returns are connected to side of furnace. Gas valve and shut offs in working order. Cleaned inside of furnace took out all insulation and dust from heating cabinet. Gas pressures good. - corroded flame sensors - standard filtration - dirty blower wheels - circuit board good - cleaned off furnaces Gonna follow up with client, gonna speak to wife about membership and upgraded filtration.