Full-Service HVAC and Plumbing in Menifee Backed by Real Guarantees
When your home needs heating, cooling, or plumbing help, Cool Air Solutions delivers dependable service with no shortcuts and no surprises. From AC tune-ups and new furnace installations to water heater repairs and leak detection, we provide expert care for every comfort system in your home. Homeowners in Menifee count on us for fast, clean, and honest service, always backed by our unbeatable guarantees.
Need service now? Reach out online or call 951-234-0748 to schedule HVAC or plumbing in Menifee today.
Heating and Cooling Experts in Menifee
We handle all things HVAC with precision and care. Whether you're upgrading to a new energy-efficient AC or your furnace isn’t keeping up, our licensed technicians bring the right tools, the right attitude, and rock-solid craftsmanship to every visit.
- AC installation, repair, and maintenance
- High-efficiency furnace and electric furnace installation
- Ductless mini-splits and zoning systems
- Smart thermostat upgrades
- Seasonal system checkups
- Air balancing and airflow improvements
Every installation comes with our full lineup of guarantees—including our Lifetime Craftsmanship Guarantee, 1-Year Test Drive, No Lemon Guarantee, and No Surprise Pricing. And if your system breaks down unexpectedly, you’re covered by our 24-Hour Fix-It Guarantee—or we pay for your hotel stay.
Licensed Plumber in Menifee, CA
Got a leak, clog, or outdated water heater? Our expert plumbing team is ready to help. We specialize in clean, efficient repairs and system replacements that restore your water flow and peace of mind.
- Water heater repair and replacement (standard and tankless)
- Slab leak detection and pipe repair
- Faucet, shower, and toilet service
- Water softeners and filtration systems
- Pressure regulators and backflow prevention
- Garbage disposals, valves, and fixtures
- Camera inspections and sewer cleaning
Our plumbers show up on time, respect your home, and deliver top-tier results backed by our Lifetime Craftsmanship Guarantee—no cut corners, no compromises.
Affordable Options with Five-Star Results
Cool Air Solutions has earned more than 8,000 five-star reviews by putting homeowners first. We offer honest pricing, flexible financing, and a Comfort Club membership to keep your systems running strong year-round.
- Flat-rate pricing with no hidden fees
- Multiple financing options are available
- Exclusive rebates and energy incentives
- Maintenance plans for better performance and fewer breakdowns
- Licensed, insured, background-checked technicians
From energy-efficient upgrades to emergency repairs, you can count on us to get the job done right—and stand behind it.
Schedule Service in Menifee Today
Experience better comfort, better service, and unbeatable protection on every HVAC and plumbing job in Menifee. Use our online form or call 951-234-0748 to book your appointment now—we’ll be there when you need us.
Recent Jobs and Reviews in Menifee, CA
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and trust. Customers consistently praise the company for delivering professional, knowledgeable, and efficient service. A recurring theme is the technical expertise and personable nature of the technicians, who are described as respectful, friendly, and genuinely passionate about their work. Many reviewers highlight the quality of major installations, including complete HVAC system replacements and ductwork, noting impressive speed and precision even under challenging conditions. The company earns strong appreciation for their transparency, thorough documentation, and clear communication about necessary services versus optional ones. Long-term customer loyalty is evident, with clients expressing continued satisfaction over multiple years and repeated service calls. The responsiveness to inquiries and commitment to standing behind their work further reinforces the positive reputation. Overall, the tone is enthusiastic and grateful, with customers feeling valued and confident in the quality and reliability of the service provided.
Menifee, CA at a glance
Cool Air Solutions has completed 25 jobs in Menifee, CA between March 2021 and April 2021.
The most recent job was on April 9, 2021.
Cool Air Solutions has completed 17 jobs in Menifee, CA in the last 12 months. The first job there was in November 2016.
Our Local Reviews by City
- Aguanga, CA (5)
- Aliso Viejo, CA (1)
- Anaheim, CA (5)
- Banning, CA (2)
- Beaumont, CA (5)
- Bonsall, CA (9)
- Buena Park, CA (2)
- Canyon Lake, CA (27)
- Carlsbad, CA (59)
- Carson, CA (1)
- Cathedral City, CA (1)
- Chino, CA (2)
- Chino Hills, CA (4)
- Chula Vista, CA (13)
- Corona, CA (51)
- Del Mar, CA (3)
- Downey, CA (1)
- Eastvale, CA (1)
- El Cajon, CA (8)
- Encinitas, CA (5)
- Escondido, CA (119)
- Fallbrook, CA (65)
- Fontana, CA (2)
- Fountain Valley, CA (2)
- Fullerton, CA (2)
- Garden Grove, CA (5)
- Hacienda Heights, CA (1)
- Hemet, CA (73)
- Homeland, CA (9)
- Huntington Beach, CA (1)
- Irvine, CA (4)
- Jurupa Valley, CA (2)
- La Verne, CA (1)
- Ladera Ranch, CA (1)
- Laguna Hills, CA (5)
- Laguna Niguel, CA (2)
- Laguna Woods, CA (1)
- Lake Elsinore, CA (119)
- Lake Forest, CA (16)
- Lakeside, CA (5)
- Lakewood, CA (1)
- Lemon Grove, CA (1)
- Los Alamitos, CA (1)
- Menifee, CA (203)
- Mission Viejo, CA (8)
- Moreno Valley, CA (26)
- Murrieta, CA (670)
- Newport Beach, CA (1)
- Norco, CA (3)
- Nuevo, CA (2)
- Oceanside, CA (86)
- Ontario, CA (1)
- Pala, CA (1)
- Pauma Valley, CA (7)
- Perris, CA (24)
- Poway, CA (9)
- Ramona, CA (4)
- Rancho Cucamonga, CA (1)
- Rancho Santa Fe, CA (2)
- Rancho Santa Margarita, CA (2)
- Redlands, CA (4)
- Riverside, CA (36)
- San Bernardino, CA (4)
- San Clemente, CA (1)
- San Diego, CA (81)
- San Dimas, CA (1)
- San Jacinto, CA (28)
- San Juan Capistrano, CA (2)
- San Marcos, CA (48)
- Santa Ana, CA (3)
- Santa Fe Springs, CA (1)
- Solana Beach, CA (1)
- Spring Valley, CA (5)
- Sun City, CA (1)
- Temecula, CA (762)
- Temescal Valley, CA (1)
- Trabuco Canyon, CA (3)
- Upland, CA (2)
- Valley Center, CA (18)
- Vista, CA (161)
- Warner Springs, CA (5)
- Wildomar, CA (77)
- Winchester, CA (125)
- Yorba Linda, CA (14)
- Yucaipa, CA (5)
Job Locations and Reviews
Performed Ac maintenance on 2020 system. Cycled system for cooling. Checked indoor unit electrical and system components. Merv filter is dirty and should be replaced, homeowner wants to order it from amazon and replace himself. Temperature split is in range and system is cooling efficiently. Checked outdoor unit electrical and system components. Amp draws are in range. Primary motor control is in good condition. Secondary motor control and compressor booster kit is within range. Pulled condenser fan motor off as well as condenser cage and thoroughly washed out condenser coil inside and out. Cycled system, system is fully operational upon departure.
Performed furnace maintenance on a Aire flo furnace. Homeowner had condensate overflow problems in the past. Condensate lines are free and clear of any debris. Combustion blower is over amping. Temperature split is in range. Blower motor and scroll wheel are clean and dry of any oil. Duct runs look good. Performed A/C maintenance on a air flow condensing unit. System was coil cleaned and reinstalled. Start and run Amps are in range. Fan motor is spinning good and clean of any oil. Starter is showing signs of failure. System was cycled and running smoothly
Replaced gas valve under warranty. The gas pressure bolt was completely stripped and the pressure could not be tested. Manufacture provided gas valve comes calibrated already no need to adjust. Checked all fittings to ensure no leaks and used fresh pipe sealant. Tested heating system and recorded temperature splits. System is working properly at this time. Additionally ran the Ac for 20 minutes to cool the furnace down and proceeded to test the heat to listen for cold fire possible noises. System is running very quiet at this time.
Inspected both systems for faults. Downstairs system is low on charge and has a leak somewhere in the equipment. Inspected the evaporator coil and found rust damage inside the primary pan and water stains from the system on the attic platform. There is no secondary drain pan or safety switch to protect the home from water damage. The downstairs Ac/coil should be replaced and a secondary pan added. The upstairs system also needs a pan but the charge is good. Recommending outdoor fan motors for both systems and a starter for the downstairs system.
Arrived on site to diagnose a no cooling system on a 2018 Ac pro. Client stated she just moved in in December and haven’t used system in cooling and turned it on and unit would turn on and house would only get warm and airflow is warm coming out of system. Upon arrival inspected unit and found a big oil spot under line set lines. Pushed shredder in and found systems flat. Added a pound In to find leak and found leak in liquid line. Bubble tested and shows client of findings. Client did want repair leak to get her up and cooling for now. Brazed liquid line. Vacuum down system to 500 microns and full charged system up to manufacture specifications. Unit was good and operational and is cooling home at 20 degrees split. Pressure were stable and good and is cooling was good at range where specified. Installed new nest thermostat, compressor booster kit and primary motor control and client signed up on ESA club. System system in cooling and heating to ensure system is operating. System is
Arrived on site to diagnose a no cooling system on a 2018 Ac pro. Client stated she just moved in in December and haven’t used system in cooling and turned it on and unit would turn on and house would only get warm and airflow is warm coming out of system. Upon arrival inspected unit and found a big oil spot under line set lines. Pushed shredder in and found systems flat. Added a pound In to find leak and found leak in liquid line. Bubble tested and shows client of findings. Client did want repair leak to get her up and cooling for now. Brazed liquid line. Vacuum down system to 500 microns and full charged system up to manufacture specifications. Unit was good and operational and is cooling home at 20 degrees split. Pressure were stable and good and is cooling was good at range where specified. Installed new nest thermostat, compressor booster kit and primary motor control and client signed up on ESA club. System system in cooling and heating to ensure system is operating. System is
Arrived on site to diagnose a no cooling system on a 2018 Ac pro. Client stated she just moved in in December and haven’t used system in cooling and turned it on and unit would turn on and house would only get warm and airflow is warm coming out of system. Upon arrival inspected unit and found a big oil spot under line set lines. Pushed shredder in and found systems flat. Added a pound In to find leak and found leak in liquid line. Bubble tested and shows client of findings. Client did want repair leak to get her up and cooling for now. Brazed liquid line. Vacuum down system to 500 microns and full charged system up to manufacture specifications. Unit was good and operational and is cooling home at 20 degrees split. Pressure were stable and good and is cooling was good at range where specified. Installed new nest thermostat, compressor booster kit and primary motor control and client signed up on ESA club. System system in cooling and heating to ensure system is operating. System is
Arrived on site to diagnose a no cooling system on a 2018 Ac pro. Client stated she just moved in in December and haven’t used system in cooling and turned it on and unit would turn on and house would only get warm and airflow is warm coming out of system. Upon arrival inspected unit and found a big oil spot under line set lines. Pushed shredder in and found systems flat. Added a pound In to find leak and found leak in liquid line. Bubble tested and shows client of findings. Client did want repair leak to get her up and cooling for now. Brazed liquid line. Vacuum down system to 500 microns and full charged system up to manufacture specifications. Unit was good and operational and is cooling home at 20 degrees split. Pressure were stable and good and is cooling was good at range where specified. Installed new nest thermostat, compressor booster kit and primary motor control and client signed up on ESA club. System system in cooling and heating to ensure system is operating. System is
Performed furnace and AC maintenance on 2015 Lennox system. Will be sending information about surge protection and PCO kit.
Financing available
Performed furnace maintenance on a 2007 Goodman. Upstairs unit. Combustion blower is amping within range. Temperature rise is within spec.Hot surface ignitor and flame sensor are clean and in range. Duct runs and condensate lines are tight and clear of any obstruction. Blower wheel has a decent amount of dust on the blades. Single run motor for the blower is failed on this unit. System does not have a safety switch on the condensate lines or sediment trap. Performed furnace maintenance on 2007 Goodman. Downstairs unit. First impression the unit has a loud sound coming from it. Checked the single run motor for the blower and it is failed. This is causing main blower To amp high for normal use getting close to being out of range. Combustion blower is good. Ignitor and flame sensor were cleaned and in range. Temperature rise is within spec. Duct lines are tight and free from obstruction. This unit also was not installed with a float switch on the condensate lines. Homeowner was informed
Inspected system for noise complaint. Tested furnace and found that the gas valve pressure regulating port has a stripped cap. The gas valve must be at 1.8 and because the cap is stripped and the pressure was likely adjusted when the unit was installed the pressure is probably out of range. Ordered a gas valve replacement and an orifice just in case the furnace has an issue with reverberating sound during operation.
Arrived on site to diagnose a over heating 1988 system. Furnace is located in home. Client stated he moved in about a month ago and client has had thermostat go blank and just recently unit would run and then shut off and fan motor would stay running. System would turn on at time and would work but over heat. Client stated he looked up what could cause system to shut off and he says it’s over heating. Inspected in door unit cycled unit 3 times and would operate but then would over heat and Tripp high limit switch and blower motor would stay on unit till unit was cooled off. Found out client had return Vent block with couch restricting airflow to unit. Found unit is restricted of air follow as static pressure is above what system is rated for and causing it to over heat after running. Found blower assembly hammered. Motor was replaced by Edison along with EcoBee thermostat. Inducer motor is pulling max amps and has dirty accumulated as well as oil leaking from inducer motor it’s sel
Arrived on site to perform fall tune up on a 2006 good man unit. Client stated no issues as she been in home for 3 years. Cycled heater and was operational. Advised I would fully evaluate system and advised client the summary of findings are as followed. Furnace 1. 2006 Goodman unit. 2. Found filter extremely dirty allowing dirt to enter system and creat airflow restrictions. 3. Blower assembly is hammered with dirt and befit from past years creating stress on motor. Recommend cleaning blower assembly to help reduce stress and wear on motor. 4. Blower motor has a thick amount of dirt and fired up oil from leaking in past from stress and wear put on motor. Motor could fail at any time due to conditions and age. Recommend replacing to extend life of unit. 5. Secondary motor controls is weak and bad as it’s out of range from motor over working and draining oblige of components. Recommend replacing before completely fails and unit will not operate. 6. Inducer motor is really loud
Inspected system cooling for operation. Measured temperature splits, inspected filter. Monitored compressor amp draws and measured refrigerant pressures. Inspected common trane leak areas.
Installation of a Lennox Single Stage ML14XC1 with high performance coil, lineset and electrical.
Technician arrived on site and started diagnosing furnace. Found the following: -blower capacitor is failing. -control board has failed. It’s not sending power to the fan. -blower motor is operational but drawing high amps. Customer declined repairs today as they are getting another bid tomorrow.
Technician arrived on site to 2 furnaces not working. Found no power to each thermostat. Downstairs unit the door switch wasn’t engaged. Fixed the panel at no additional charge. Upstairs unit had a blown fuse. Got approval from the homeowner to replace fuse. Tested system operation. Found multiple electrical components failing. -inducer over amping. -blower almost over amping. -both blower caps are out of range. Advised customer and he declined repairs. Also declined maintenance membership.
Installation of a XC16 2-Stage 17 SEER Air Conditioner with a High Performance High Efficiency Coil, Cut in (4) R-8 duct supplies & (3) R-8 duct returns. Installation of lineset to relocate condenser to the left side yard including 208v Circuit.
Replace existing system with listed equipment.
Remove tape from air orifice and tested and verify correct operation of system.
Heating and cooling combo tuneup. Replaced filter. Tested all temperature and electrical diagnostics. Cleaned components and outdoor coils. Monitored operation and safeties.
Performed one system maintenance on Lennox system. On maintenance AC Side of system checked out properly refrigerant pressures were adequate and all electrical checked out and range, Condenser coil was heavily covered in dust and hair from dogs all those cleaned off and ready for summer. Heating side of system checked out on safety inspection and had a 35° temperature rise which is in range. Flame sensor was cleaned. Gas fittings are secured and sealed along with duct work properly sealed. Circuit board was in good condition and motor was not leaking any oil or signs of over amping. Client will be ordering filters and have on hand next visit. Programmed mini split remote to Lennox system and system is now controllable through remote. Upon departure system is fully operational in heating mode and cooling.
Technician arrived on site. Was informed that the unit will come on and off. Unit is operational at time of inspection. Started heater maintenance. Cycled unit on and off. Started checking ignition components. No hard failure at this time. However found multiple issues with the that will fail. -inducer motor is over amping -blower cap is low. -blower motor needs a cleaning. Went over prices with homeowners. Decided to look at all options including replacement of unit.
Preformed heatpump maintenance on 7 year old Lennox system. Cleaned condenser coils due to them being dirty. Verified R410a charge was correct. Electrical amp are in proper range. Duel secondary motor control in range. High voltage relay had sight pitting. Merv 16 filter to swapped out next visit. Discussed whole house purification system to create better indoor filtration. Upon departure system is heating correctly