Full-Service HVAC and Plumbing in Menifee Backed by Real Guarantees
When your home needs heating, cooling, or plumbing help, Cool Air Solutions delivers dependable service with no shortcuts and no surprises. From AC tune-ups and new furnace installations to water heater repairs and leak detection, we provide expert care for every comfort system in your home. Homeowners in Menifee count on us for fast, clean, and honest service, always backed by our unbeatable guarantees.
Need service now? Reach out online or call 951-234-0748 to schedule HVAC or plumbing in Menifee today.
Heating and Cooling Experts in Menifee
We handle all things HVAC with precision and care. Whether you're upgrading to a new energy-efficient AC or your furnace isn’t keeping up, our licensed technicians bring the right tools, the right attitude, and rock-solid craftsmanship to every visit.
- AC installation, repair, and maintenance
- High-efficiency furnace and electric furnace installation
- Ductless mini-splits and zoning systems
- Smart thermostat upgrades
- Seasonal system checkups
- Air balancing and airflow improvements
Every installation comes with our full lineup of guarantees—including our Lifetime Craftsmanship Guarantee, 1-Year Test Drive, No Lemon Guarantee, and No Surprise Pricing. And if your system breaks down unexpectedly, you’re covered by our 24-Hour Fix-It Guarantee—or we pay for your hotel stay.
Licensed Plumber in Menifee, CA
Got a leak, clog, or outdated water heater? Our expert plumbing team is ready to help. We specialize in clean, efficient repairs and system replacements that restore your water flow and peace of mind.
- Water heater repair and replacement (standard and tankless)
- Slab leak detection and pipe repair
- Faucet, shower, and toilet service
- Water softeners and filtration systems
- Pressure regulators and backflow prevention
- Garbage disposals, valves, and fixtures
- Camera inspections and sewer cleaning
Our plumbers show up on time, respect your home, and deliver top-tier results backed by our Lifetime Craftsmanship Guarantee—no cut corners, no compromises.
Affordable Options with Five-Star Results
Cool Air Solutions has earned more than 8,000 five-star reviews by putting homeowners first. We offer honest pricing, flexible financing, and a Comfort Club membership to keep your systems running strong year-round.
- Flat-rate pricing with no hidden fees
- Multiple financing options are available
- Exclusive rebates and energy incentives
- Maintenance plans for better performance and fewer breakdowns
- Licensed, insured, background-checked technicians
From energy-efficient upgrades to emergency repairs, you can count on us to get the job done right—and stand behind it.
Schedule Service in Menifee Today
Experience better comfort, better service, and unbeatable protection on every HVAC and plumbing job in Menifee. Use our online form or call 951-234-0748 to book your appointment now—we’ll be there when you need us.
Recent Jobs and Reviews in Menifee, CA
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and trust. Customers consistently praise the company for delivering professional, knowledgeable, and efficient service. A recurring theme is the technical expertise and personable nature of the technicians, who are described as respectful, friendly, and genuinely passionate about their work. Many reviewers highlight the quality of major installations, including complete HVAC system replacements and ductwork, noting impressive speed and precision even under challenging conditions. The company earns strong appreciation for their transparency, thorough documentation, and clear communication about necessary services versus optional ones. Long-term customer loyalty is evident, with clients expressing continued satisfaction over multiple years and repeated service calls. The responsiveness to inquiries and commitment to standing behind their work further reinforces the positive reputation. Overall, the tone is enthusiastic and grateful, with customers feeling valued and confident in the quality and reliability of the service provided.
Menifee, CA at a glance
Cool Air Solutions has completed 25 jobs in Menifee, CA between April 2021 and May 2021.
The most recent job was on May 24, 2021.
Cool Air Solutions has completed 17 jobs in Menifee, CA in the last 12 months. The first job there was in November 2016.
Our Local Reviews by City
- Aguanga, CA (5)
- Aliso Viejo, CA (1)
- Anaheim, CA (5)
- Banning, CA (2)
- Beaumont, CA (5)
- Bonsall, CA (9)
- Buena Park, CA (2)
- Canyon Lake, CA (27)
- Carlsbad, CA (59)
- Carson, CA (1)
- Cathedral City, CA (1)
- Chino, CA (2)
- Chino Hills, CA (4)
- Chula Vista, CA (13)
- Corona, CA (51)
- Del Mar, CA (3)
- Downey, CA (1)
- Eastvale, CA (1)
- El Cajon, CA (8)
- Encinitas, CA (5)
- Escondido, CA (119)
- Fallbrook, CA (65)
- Fontana, CA (2)
- Fountain Valley, CA (2)
- Fullerton, CA (2)
- Garden Grove, CA (5)
- Hacienda Heights, CA (1)
- Hemet, CA (73)
- Homeland, CA (9)
- Huntington Beach, CA (1)
- Irvine, CA (4)
- Jurupa Valley, CA (2)
- La Verne, CA (1)
- Ladera Ranch, CA (1)
- Laguna Hills, CA (5)
- Laguna Niguel, CA (2)
- Laguna Woods, CA (1)
- Lake Elsinore, CA (119)
- Lake Forest, CA (16)
- Lakeside, CA (5)
- Lakewood, CA (1)
- Lemon Grove, CA (1)
- Los Alamitos, CA (1)
- Menifee, CA (203)
- Mission Viejo, CA (8)
- Moreno Valley, CA (26)
- Murrieta, CA (670)
- Newport Beach, CA (1)
- Norco, CA (3)
- Nuevo, CA (2)
- Oceanside, CA (86)
- Ontario, CA (1)
- Pala, CA (1)
- Pauma Valley, CA (7)
- Perris, CA (24)
- Poway, CA (9)
- Ramona, CA (4)
- Rancho Cucamonga, CA (1)
- Rancho Santa Fe, CA (2)
- Rancho Santa Margarita, CA (2)
- Redlands, CA (4)
- Riverside, CA (36)
- San Bernardino, CA (4)
- San Clemente, CA (1)
- San Diego, CA (81)
- San Dimas, CA (1)
- San Jacinto, CA (28)
- San Juan Capistrano, CA (2)
- San Marcos, CA (48)
- Santa Ana, CA (3)
- Santa Fe Springs, CA (1)
- Solana Beach, CA (1)
- Spring Valley, CA (5)
- Sun City, CA (1)
- Temecula, CA (762)
- Temescal Valley, CA (1)
- Trabuco Canyon, CA (3)
- Upland, CA (2)
- Valley Center, CA (18)
- Vista, CA (161)
- Warner Springs, CA (5)
- Wildomar, CA (77)
- Winchester, CA (125)
- Yorba Linda, CA (14)
- Yucaipa, CA (5)
Job Locations and Reviews
Performed AC maintenance on an AC pro system. Cooling split is 23 degrees. Indoor blower is amping in range. Condensate lines are clear. Outdoor unit was chemically cleaned. Amp draws are all in range at this time. Refrigerant levels are ok. Customer reported the system turning off randomly. When this happens they unplug the indoor unit and plug it back in to fix it. Electrical socket has burn marks on it. System was working fine during my visit
Performed AC maintenance on 3 year old carrier systems. Cycled units for cooling. Checked indoor and outdoor units electrical and system components, refrigerant pressures are in range and systems are producing proper temperature split. Removed outdoor condenser coil and thoroughly washed out condenser coils inside and out. Amp draws are in good range. Primary and secondary motor control check off good. There are no fuses on outdoor disconnect boxes. Also recommend adding compressor booster kits to help the compressors on start up and prevent extra wear and tear. Husband was at work. Could not go over recommendations, would just like them emailed. Replaced 1 inch filters. System is fully operational upon departure.
Arrived on site to perform prong tune up on a 2015 unit comfortmaker unit. Condenser located on site of home. Furnace and Evaporator coil located in attic. Client stated no issues as they just moved in and wanted system inspected as there home warranty came out and they did now like how they worked. Washed condenser inside and out. Condenser coil is bad shape from past fog peeing on coil. And thermostat wires were replaced in passed as dog chewed them up. Fan motor leaking oil and almost at max amps. Primary is burnt up and crating ticking noise. Secondary for fan and compressor are both good. Compressor start up are at max. Run amps are almost at max as seek as it’s pulling 24 amps and max rated at 27. Compressor is working really hard and could fail ay any time. Advised compressor is on borrowed time and could fail at any time due to conditions and over all condition. Unit uses R-22 which is no longer in production. No protection on unit. Cycled unit. Inspected indoor unit. Replac
Performed maintenance on 2 package units. Cycled systems for cooling. Checked unit electrical and system components. Temperature split across both units is within range and systems are cooling correctly. Secondary motor controls are in range for both units. Primary motor controls are in good condition. Pullled condenser fan motors and thoroughly washed out condenser coils inside and out. Went over findings and recommendations with homeowner. Fully aware of the condition of the units. Cycled system, system is operational upon departure.
Arrived on site to perform AC diagnostic on 2006 Lennox unit. They just moved into the home a couple months ago. Homeowner says upstairs unit works, but not too well. Had another company come out to diagnose and they told him that the system was out of refrigerant and that he needed to replace it, wanted to get a second opinion on that. Cycled system for cooling. Unit kicks on normally. System is only producing 15 degree temp split, and refrigerant levels are low. Filter is also extremely dirty, replaced filter to get accurate readings. System is cooling, but needs refrigerant to cool back to manufacture specs. System could have a possible leak, or maybe it has never been operating on a proper charge. Went over findings and recommendations with homeowners. Went through the cost of repairs, and possibility having a leak. They do not and are not in a position to replace, and want to try and hold off as much as possible. They approved adding refrigerant and leak dye/seal. Also signed up o
Upon arrival performed maintenance on ac system. Refrigerant levels in range. Primary nd secondary motor control good. Hardstart kit in working order. Replaced filter client provided. Disconnect I’m great condtion. Opened up and washed outdoor system. Dusted all electrical connections. Wiped down furnace cabinet. Client stated he heard a clicking noise on heat, ran heat did not hear anything checked wiring or lose components.
Upon arrival performed maintenance on ac system. Refrigerant levels in range. Primary nd secondary motor control good. Hardstart kit in working order. Replaced filter client provided. Disconnect I’m great condtion. Opened up and washed outdoor system. Dusted all electrical connections. Wiped down furnace cabinet. Client stated he heard a clicking noise on heat, ran heat did not hear anything checked wiring or lose components.
Upon arrival performed maintenance on ac system. Refrigerant levels in range. Primary nd secondary motor control good. Hardstart kit in working order. Replaced filter client provided. Disconnect I’m great condtion. Opened up and washed outdoor system. Dusted all electrical connections. Wiped down furnace cabinet. Client stated he heard a clicking noise on heat, ran heat did not hear anything checked wiring or lose components.
Upon arrival performed maintenance on ac system. Refrigerant levels in range. Primary nd secondary motor control good. Hardstart kit in working order. Replaced filter client provided. Disconnect I’m great condtion. Opened up and washed outdoor system. Dusted all electrical connections. Wiped down furnace cabinet. Client stated he heard a clicking noise on heat, ran heat did not hear anything checked wiring or lose components.
Tech arrived on site. Found no power to the thermostat. Fuse on control board was popped. Replaced fuse and tested fan and heating. It was good. Tried cooling and it popped. Removed low voltage wires to the contractor outside. Tested cooling again and it didn’t pop. Ohmed out low voltage terminals and found the contractor to be bad. Replaced contractor and the unit began to cool.
Upon arrival performed diagnositc on Package unit on roof. Client had replaced breaker thinking breaker was bad. Replaced and still kept tripping system. Found compressor to be grounded on the start terminal. System, is not operational. Darren to come out tomorrow morning to give replacement options.
Upon arrival performed diagnositc on Package unit on roof. Client had replaced breaker thinking breaker was bad. Replaced and still kept tripping system. Found compressor to be grounded on the start terminal. System, is not operational. Darren to come out tomorrow morning to give replacement options.
Upon arrival performed diagnositc on Package unit on roof. Client had replaced breaker thinking breaker was bad. Replaced and still kept tripping system. Found compressor to be grounded on the start terminal. System, is not operational. Darren to come out tomorrow morning to give replacement options.
Upon arrival performed diagnositc on Package unit on roof. Client had replaced breaker thinking breaker was bad. Replaced and still kept tripping system. Found compressor to be grounded on the start terminal. System, is not operational. Darren to come out tomorrow morning to give replacement options.
Tech arrived on and found 1 hvac system operational. Homeowner said unit wasn’t cooling yesterday. Found the capacitor to be low. Wiring was a mess. Cleaned up the wiring, and installed a new capacitor. Cleaned out the electrical. Tested unit and it’s operational. Helped customer install the nest app and hook up WiFi. 1 year parts labor warranty on the capacitor. Membership is for 1 year at $14.95. After a year it can be canceled.
Arrived on site to perform spring tune up on a 2009 Goodman unit. Client stated no issues as they have yet to use system. Condenser located in back yard. Furnace and Evaporator coil located in attic. Washed condenser coil inside and out. Primary is burnt up on contact points from self wear. Secondary motor controls is good. Fan motor is working at max rate. Could fail in future from self wear. Checked compressor amps. Start ups was really high and over max from self wear and age. Run amps are good and in range. System pressure are good and cooling home at 20 degrees. System uses R-22 refrigerant and no longer in production. Inspected indoor unit. Filter was slightly dusty but good. Blower assembly and motor are good. Evaporator coil has slight dust and debris from past dirty that has entered system. No protection on out door unit. Cycled system. Went over all findings and recommendations with client. Client is aware of how system is and it’s condition. Client did declined recommended
Performed AC maintenance on 2019 AC Pro condenser.
Performed system diagnostic on 2012 Goodman. Upon my diagnostic homeowner stated that water is been leaking from under the system since Sunday. Advise me that a plumber that came out and said there was no issue with the water heater in that it Has to be related to the HVAC system. Further into my diagnostic I inspected the system and found that water was filling up in the return platform. Tested the primary condensate line is draining out properly and primed it with four bottles of water, No issue with draining or signs of flooding. There is also a secondary float switch in the case of the flood ever does occur this would actually trip the system and turn it off before water ever has a possibility of leaking out. Did further investigation and this may be due to a possible slab leak from the plumbing, Found out the water meter out front is continuously moving even though there’s no running water in the home. Notified homeowner and he is having a plumber come out. Upon departure system
Quality control check
Performed cooling maintenance on 10 year old Lennox system. Installed by us. Cycled system for cooling. Checked outdoor unit electrical and system components. Refrigerant pressures are in range and system is producing proper temperature split. Primary motor control is starting to hum on low voltage coil. Secondary motor control is out of range for condenser fan motor side. Compressor amp draws are in range, but on start up it is loud and hard. Pulled off condenser fan motor as well as all condenser Panels and thoroughly washed condenser coil inside and out. Checked indoor unit electrical and system components. Filter is ok, homeowner replaces himself every 3 months. Went over findings and recommendations with homeowner. He wants to take care of repairs but is not ready at the moment, but wants to do it before summer. He will call in when he wants us to come out and take care of it. Cycled system. System is fully operational upon departure.
Arrived on site to perform AC maintenance on package unit. Home has 2 systems, we are only working on the unit on the roof as that is the older of the two. Homeowners just recently moved into home. They had inspection done that said everything was ok, but they want to get it checked. Cycled system for cooling. Checked package unit components and electrical. Compressor amp draws are close to over amping. Amp draws on indoor fan motor and condenser fan motor are going over allowed range, and indoor blower motor has started to leak oil. Temperature split is in range and refrigerant pressures good. Indoor blower wheel is dirty. Primary motor control has some pitting and burning marks at contact points. Rinsed off outdoor condenser coil. Performed attic duct inspection. Ducts are old and outer liner is starting to fall off. System is still operating, but it is older and super inefficient and parts are going to start failing. Went over findings and recommendations with homeowners. They want
Performed AC diagnostic on 2007 carrier condenser. Prior to diagnostic Mac had stated that home warranty had done a diagnosis on the system and recommended that he replaced everything due to it not working. I begin my diagnostic at the outdoor unit and found that it was not energized with 240 V. Capacitor was also replaced and left accidentally buy home warranty company. Found that outdoor breaker coming from panel were miss labeled And breaker for AC was off. Flipped the breaker back in the on position And system fired up properly. Compressor was pulling 9 Amps considering at the highest is 14. System also contained R22 refrigerant which was completely phased out January 1, 2020. Contactor was pitted. Indoor unit was from 1989 and had original evaporator coil that was covered in duct tape. Also found signs of water leakage coming from primary pan of the evap coil due to it rusting out over the years. Ultimately system worked but Mac would like to replace the system once he moves into
Arrived on site to return to install phenomenal air on a 2017 lennox system. Furnace and evaporator coil located in garage. Discharged unit and made whole bigger installed and secured unit and has good airflow. Cycled system. Unit is operational as client leaves fan mode on. Client is aware of how system works and registered client up for her warranty. System is operational upon departure. Collected remaining balance. Client is happy with repairs and work done. System operational upon departure.
Performed diagnostic on system. Homeowner states that his nest thermostat says it has no power. Happened yesterday morning. Checked for power at thermostat and not recieving 24 volts. Went into attic and found a broken fuse. Used pigtail fuse to see if unit had a short, system tripped fuse as soon as power was restored. Troubleshoot the short down to a bad outdoor defrost board. Defrost board needs to be replaced. System is in poor condition as well as ducting has rips and tears throughout the tubes. Went over findings and recommendations with homeowner. Homeowner thought price was too much, said he has a friend in San Diego that could do it but he couldn’t get him out here today. Said He will be ordering parts and doing the repairs himself. No work performed other than the diagnostic.
Arrived on site to perform combo tune up on a 2017 lennox unit. Client renewed over phone. Condenser located on side of home client stated no issues just wanted service. Washed condenser coil inside and out. All electrical and components are good and in range. Compressor amp draws are good. Fan motor is good and in range. System pressure is good and cooling home at 20 degrees. Inspected indoor unit. Filter was dirty and needing replacement. Blower assembly and wheel is good. Motor is good. Inducer motor is good. Drain lines are good and in range. Found air scrubber purifying system bulb burnt and bad. Recommend adding a phenomenal air to prevent maintenance and yearly replacement parts and would better air quality. Evaporator coil is good. System is heating and cooling good. Client dose want to go forward with adding phenomenal air to system to not be having to do maintenance. Unable due to time and would have to come back out and install. Collected amount of $100 for deposits. System