Full-Service HVAC and Plumbing in Menifee Backed by Real Guarantees
When your home needs heating, cooling, or plumbing help, Cool Air Solutions delivers dependable service with no shortcuts and no surprises. From AC tune-ups and new furnace installations to water heater repairs and leak detection, we provide expert care for every comfort system in your home. Homeowners in Menifee count on us for fast, clean, and honest service, always backed by our unbeatable guarantees.
Need service now? Reach out online or call 951-234-0748 to schedule HVAC or plumbing in Menifee today.
Heating and Cooling Experts in Menifee
We handle all things HVAC with precision and care. Whether you're upgrading to a new energy-efficient AC or your furnace isn’t keeping up, our licensed technicians bring the right tools, the right attitude, and rock-solid craftsmanship to every visit.
- AC installation, repair, and maintenance
- High-efficiency furnace and electric furnace installation
- Ductless mini-splits and zoning systems
- Smart thermostat upgrades
- Seasonal system checkups
- Air balancing and airflow improvements
Every installation comes with our full lineup of guarantees—including our Lifetime Craftsmanship Guarantee, 1-Year Test Drive, No Lemon Guarantee, and No Surprise Pricing. And if your system breaks down unexpectedly, you’re covered by our 24-Hour Fix-It Guarantee—or we pay for your hotel stay.
Licensed Plumber in Menifee, CA
Got a leak, clog, or outdated water heater? Our expert plumbing team is ready to help. We specialize in clean, efficient repairs and system replacements that restore your water flow and peace of mind.
- Water heater repair and replacement (standard and tankless)
- Slab leak detection and pipe repair
- Faucet, shower, and toilet service
- Water softeners and filtration systems
- Pressure regulators and backflow prevention
- Garbage disposals, valves, and fixtures
- Camera inspections and sewer cleaning
Our plumbers show up on time, respect your home, and deliver top-tier results backed by our Lifetime Craftsmanship Guarantee—no cut corners, no compromises.
Affordable Options with Five-Star Results
Cool Air Solutions has earned more than 8,000 five-star reviews by putting homeowners first. We offer honest pricing, flexible financing, and a Comfort Club membership to keep your systems running strong year-round.
- Flat-rate pricing with no hidden fees
- Multiple financing options are available
- Exclusive rebates and energy incentives
- Maintenance plans for better performance and fewer breakdowns
- Licensed, insured, background-checked technicians
From energy-efficient upgrades to emergency repairs, you can count on us to get the job done right—and stand behind it.
Schedule Service in Menifee Today
Experience better comfort, better service, and unbeatable protection on every HVAC and plumbing job in Menifee. Use our online form or call 951-234-0748 to book your appointment now—we’ll be there when you need us.
Recent Jobs and Reviews in Menifee, CA
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and trust. Customers consistently praise the company for delivering professional, knowledgeable, and efficient service. A recurring theme is the technical expertise and personable nature of the technicians, who are described as respectful, friendly, and genuinely passionate about their work. Many reviewers highlight the quality of major installations, including complete HVAC system replacements and ductwork, noting impressive speed and precision even under challenging conditions. The company earns strong appreciation for their transparency, thorough documentation, and clear communication about necessary services versus optional ones. Long-term customer loyalty is evident, with clients expressing continued satisfaction over multiple years and repeated service calls. The responsiveness to inquiries and commitment to standing behind their work further reinforces the positive reputation. Overall, the tone is enthusiastic and grateful, with customers feeling valued and confident in the quality and reliability of the service provided.
Menifee, CA at a glance
Cool Air Solutions has completed 25 jobs in Menifee, CA between September 2022 and October 2022.
The most recent job was on October 15, 2022.
Cool Air Solutions has completed 18 jobs in Menifee, CA in the last 12 months. The first job there was in November 2016.
Our Local Reviews by City
- Aguanga, CA (5)
- Aliso Viejo, CA (1)
- Anaheim, CA (5)
- Banning, CA (2)
- Beaumont, CA (5)
- Bonsall, CA (9)
- Buena Park, CA (2)
- Canyon Lake, CA (27)
- Carlsbad, CA (59)
- Carson, CA (1)
- Cathedral City, CA (1)
- Chino, CA (2)
- Chino Hills, CA (4)
- Chula Vista, CA (13)
- Corona, CA (51)
- Del Mar, CA (3)
- Downey, CA (1)
- Eastvale, CA (1)
- El Cajon, CA (8)
- Encinitas, CA (5)
- Escondido, CA (119)
- Fallbrook, CA (65)
- Fontana, CA (2)
- Fountain Valley, CA (2)
- Fullerton, CA (2)
- Garden Grove, CA (5)
- Hacienda Heights, CA (1)
- Hemet, CA (73)
- Homeland, CA (9)
- Huntington Beach, CA (1)
- Irvine, CA (4)
- Jurupa Valley, CA (2)
- La Verne, CA (1)
- Ladera Ranch, CA (1)
- Laguna Hills, CA (5)
- Laguna Niguel, CA (2)
- Laguna Woods, CA (1)
- Lake Elsinore, CA (119)
- Lake Forest, CA (16)
- Lakeside, CA (5)
- Lakewood, CA (1)
- Lemon Grove, CA (1)
- Los Alamitos, CA (1)
- Menifee, CA (203)
- Mission Viejo, CA (8)
- Moreno Valley, CA (26)
- Murrieta, CA (670)
- Newport Beach, CA (1)
- Norco, CA (3)
- Nuevo, CA (2)
- Oceanside, CA (86)
- Ontario, CA (1)
- Pala, CA (1)
- Pauma Valley, CA (7)
- Perris, CA (24)
- Poway, CA (9)
- Ramona, CA (4)
- Rancho Cucamonga, CA (1)
- Rancho Santa Fe, CA (2)
- Rancho Santa Margarita, CA (2)
- Redlands, CA (4)
- Riverside, CA (36)
- San Bernardino, CA (4)
- San Clemente, CA (1)
- San Diego, CA (81)
- San Dimas, CA (1)
- San Jacinto, CA (28)
- San Juan Capistrano, CA (2)
- San Marcos, CA (48)
- Santa Ana, CA (3)
- Santa Fe Springs, CA (1)
- Solana Beach, CA (1)
- Spring Valley, CA (5)
- Sun City, CA (1)
- Temecula, CA (762)
- Temescal Valley, CA (1)
- Trabuco Canyon, CA (3)
- Upland, CA (2)
- Valley Center, CA (18)
- Vista, CA (161)
- Warner Springs, CA (5)
- Wildomar, CA (77)
- Winchester, CA (125)
- Yorba Linda, CA (14)
- Yucaipa, CA (5)
Job Locations and Reviews
Performed diagnostic on 16 year old Aire Flo system. Upon inspection, it was found that the dual secondary motor control was dead on both sides resulting in the compressor not starting and the condenser fan motor rotating backwards. A new dual secondary motor control was installed. It was recommended to replace the condenser fan motor, start contactor, and install a compressor saver kit. Due to the expense of repairs and the age of the unit Jasmin and Terry are having a comfort advisor come out on Tuesday 10/18/22 at 7pm to go over replacement options. Upon departure system is operational.
Arrived on site to perform maintenance on Goodman furnace. Cycled system for heating. Verified proper heating sequence of operations. Temperature rise across heat exchanger is on higher end of allowed range by manufacturer. Ran system through 20 point inspection. Cleaned out return register and replaced filter. Recommended replacing more frequently. Indoor motor seals have gone bad, and motor has leaked oil. Motor condition is being heavily affected by a dirty blower wheel. Also, Ducting is very undersized which is causing high pressure in the unit, also affecting the motor as well as the temperature rise. Opened evaporator coil to access visual inspection of heat exchanger. After inspection, was able to notice that heat exchanger had very noticeable hot spots on lower tubes. Could not visably see any cracks at this time. Went over findings and recommendations with Michael, also spoke about getting a proper heat exchanger inspection. Wanted to hold off on anything for today. Understand
During my twenty point heating inspection, I started with the thermostat. Giving a call for heating, and going to furnace to start maintenance. Temp rise of 35-65 needed, I got a temp rise of 40. House heats up to designated temperature. I checked out blower motor of any dirt or debris. Air filter was replaced by owner already. Hot surface igniter not cracked or having white spots. Flame sensor still working good, no need to be cleaned. Ducting done correctly, and all runs intact. Inducer motor is working efficiently. House heats good and ready for winter.
Performed an AC maintenance on two 2015 carrier systems. Both systems where chemically bathed and thoroughly washed. Checked pressures and temperature splits and both where not in range. The pressures for both units looked slightly low and the temperature splits where reading 16* and 14* degrees which leads me to believe that both units might be slightly low. Checked all electrical components and everything was in range, besides the fan motors one was running close to max amperage 1.3/1.4 and the other was running at max amperage 0.5/0.5. I brought everything up the customers and they where aware of the current situation. Filters where changed this visit. System was fully operational at time of departure.
Upon arrival performed diagnostic. Found system to have no power at system at all. Reset breaker and system kicked on. Did find that the compressor is running At max ampergess. So compressor is just over working itself. System has very dirty filters needs maintenance done to system. Compressor might start giving more issues as electrical is running extremely high. Found compressor running at 17.9 amps when system is maxed out at 19. System can start tripping breaker consistently depending on how hard compressor runs during day .
Upon arrival performed diagnostic. Found system to have no power at system at all. Reset breaker and system kicked on. Did find that the compressor is running At max ampergess. So compressor is just over working itself. System has very dirty filters needs maintenance done to system. Compressor might start giving more issues as electrical is running extremely high. Found compressor running at 17.9 amps when system is maxed out at 19. System can start tripping breaker consistently depending on how hard compressor runs during day .
Upon arrival performed diagnostic. Found system to have no power at system at all. Reset breaker and system kicked on. Did find that the compressor is running At max ampergess. So compressor is just over working itself. System has very dirty filters needs maintenance done to system. Compressor might start giving more issues as electrical is running extremely high. Found compressor running at 17.9 amps when system is maxed out at 19. System can start tripping breaker consistently depending on how hard compressor runs during day .
Upon arrival performed diagnostic. Found system to have no power at system at all. Reset breaker and system kicked on. Did find that the compressor is running At max ampergess. So compressor is just over working itself. System has very dirty filters needs maintenance done to system. Compressor might start giving more issues as electrical is running extremely high. Found compressor running at 17.9 amps when system is maxed out at 19. System can start tripping breaker consistently depending on how hard compressor runs during day .
Upon arrival arrival unit was operational. Checked amps in the furnace they were in range, condensation line was cleared out, blower wheel was free of oil. Temp rise was in range and safety switches were functioning properly.upon departure unit was operational and heating.
When I arrived at home, I was told condenser unit wouldn’t work. I opened up condenser cabinet and checked out all electrical components. I found a bad condenser fan motor, exceeded max amps. Fan motor only spins with a push of object. Compressor amps exceeded to 34 amps, max amps was 22.2. System will shut off after a bit of running. High limit switch keeps tripping in system. Owner is aware of everything defected in system, I had him visually check it out with me. He would like to speak with supervisor. Supervisor will come out later in evening. Charging for diagnostic only today. Paid cash.
Installed phenomenal aire
Arrived on site to perform AC inspection on York condensing unit. Upon arrival Gary stated Did you recently had the outdoor condensing unit replaced and it had not cooled his house below 78 degrees, also cycles on and off resulting in an extremely high energy bill. He mentioned he had someone replace the unit and no inspector or HERS Tester came out to verify work was done to city code. Began diagnostic at outdoor unit and immediately found that pressures were fluctuating indicating that they were possible noncondensibles and contaminants within the refrigeration cycle. Client also mentioned the previous installer that put unit stated on invoice that TXV will be installed and fixed orifice piston would be removed to improve efficiency of new R410a system. Inspected indoor evaporator coil and found that it was the original R22 coil and no TXV was installed. It is unknown what the installer did whether or not he pulled a vacuum and flushed nitrogen through refrigerant lines removing orig
Didn’t want me to go up to furnace just did temp split from return vent and supply vent. And changed filter.
Arrived on site to diagnose a no operational unit. 2004 Ac unit. Spoke to client upon arrival and she stated thermostat is not operational and recently went blank. Before it was blowing warm air. Now nothing. Inspected Indoor unit. Found ducting to be old and not insulated advised ducting should be replaced as it’s losing cooling in attic and units runs longer. Found filter extremely clogged up and causing motor to leak. Client are having home remodeled due to a leak. Looks like unit has been ran in past months as unit is dirty and motor has been leaking oil recently as it’s wet. Found no power to unit. Checked breaker and found main breaker switch was tripped and off so most of home did not have power. Spoke to daughter and she stated that her dad and brother said they have been needing to replace it just haven’t. Got it to flip over and Inspected full unit. Blower motor leaking. Secondary motor control for blower is out of range. Evaporator coil is dirty. Drain lines have bui
Returned to perform leak dye inspection. After thoroughly inspecting indoor and outdoor coils, as well as lineset, was able to locate the leak at the outdoor condenser. Leak was caused by two lines being too close together, and the vibration of the unit caused one pipe to rub onto the other. Shared findings with homeowner. Called And verified with American Standard that unit is no longer in warranty. Representative stated that he could not give me a price or availability on coil today, and actually recommended to just replace the unit. I caught them as they were closing, will try again on Monday and follow up with Victor as far as pricing for new coil. System is not operational upon departure.
Arrived on site to perform diagnostic on 2003 Lennox unit. Homeowner states upstairs unit it not working. It is blowing air, but not cold air. Cycled system for cooling. Unit kicked on, but is not producing any temperature split. Checked outdoor unit electrical and system components. Condenser fan motor sounds very bad, bearings on it are starting to give out. Gauged up to unit and found that refrigerant cycle has a big restriction in it. Compressor overheated and shut off due to no refrigerant making it back to it. Went into attic to open up coil and see if I can get piston unstuck. Had no luck and piston as well as all refrigerant will have to get replaced to ensure no contaminants in the line to affect new piston. Went over findings and recommendations with homeowner. He needs to talk it over with his wife, but ultimately wants to explore some replacement options. Turned call over for replacement options on Thursday from 5-7. Left disconnect in off position. upstairs Unit is not ope
Performed diagnostic. Homeowner states system is not cooling. Air coming out of the vents does not feel cold. Cycled system for cooling. Indoor and outdoor equipment cycled on like normal. System is only producing about 12 degree temp split. Gauged up to unit and found system to be low on refrigerant. Went over findings and recommendations. With approval, charged unit back up with 3 pounds of r410A refrigerant and injected system with leak dye. Homeowner understands the process to locate leak, as well as what comes after leak is located. Price of leak repair is going to be dependent of where unit is leaking from. Homeowner to reach out to us when cooling efficiency drops to perform leak search. Cycled system, system is operational upon departure.
Client stated no cooling -Condenser was not operating -Capacitor was out of range -Error code said it was locked out, it was not, capacitor was the issue -Booster Kit was also installed to lower starting amps on the compressor -Client is now apart of our comfort club -System is currently cooling
Technician arrived to perform maintenance for Furnace -Filter is clean, size is (20x25x5 MERV 13) -Flame sensor is clean -Igniter working properly -Inducer motor has resistance -Dampers were recommended as client stated he has issues with having balanced airflow to master bedroom and further rooms -Ducting is intact and not leaking any air -System is currently heating
Arrived on site to perform diagnostic on system. Homeowner states that unit has since started working again but would like to get it checked out anyways. Cycled system for cooling, unit kicked on normally. Checked indoor and outdoor unit electrical and system components. Primary and secondary motor controls in good condition and in range. Compressor amp draws are high. Fan motor was just recently replaced by his sons friend. Indoor circuit board is not showing any heat marks or signs of failure. Indoor blower wheel is dirty, and motor is starting to leak oil. Could not pin point exact problem, but system does show signs of age. Signed up on maintenance program. System is operational upon departure.
Arrived on site to diagnose unit not working. Unknown age of unit. Client stated some one broke into home and cut, ripped and unwired and unit mounted condenser and wires in furnace. Disconnect is missing. Thermostat was knocked off wall and hanging. He stated they went into attic and unwired unit in furnace as well. Advised client this was more then stated over phone. Got pricing from management to do rewiring with no guarantee. Due to the fact that he has a lot going on. Client was under the impression that the 98 was including the repair but client has full condenser disconnected. Advised client of repairs and he did not want to move forward with them as he thought doing all that would be simple fix. Client was aware of the charge of coming out for 98 but refused to pay. Advised him office will bill for coming out. He was informed and Left.
Performed an AC maintenance on a 2020 Lennox system. System was chemically bathed and thoroughly washed. Checked pressures and temperature splits and both where in range. Checked all electrical components and everything was in range. Filters where changed this visit, customer provided. System was fully operational at time of departure.
Upon arrival performed AC tuneup on 2 year old Allied system. Performed static pressure test and found to be high. Temperature split was normal. Checked electrical components and connections and all looked good. Inspected blower compartment and it is clean and blower sounds balanced. Flushed condensation drain line with half gallon of water. Replaced filter with owner-suppled filter. Performed deep cleaning on condenser coil fins and exterior unit. Checked electrical components and all looked good. Noticed start amps were high. Recommended compressor saver kit but Lana would not like to put any more money into the system at this time. Refrigerant temperatures and pressures were normal. Upon departure system is operational.
Performed an AC maintenance on a 2021 Lennox system. System was chemically bathed and thoroughly washed. Pressures and temperature splits where checked and both are in range. Checked all electrical components and everything was in range. Filters where not swapped this visit. System was fully operational on time of departure.
Full system installed -Under 300 microns, passed decay test -Nitrogen pressure test 400 psi for 15 minutes