Full-Service HVAC and Plumbing in Menifee Backed by Real Guarantees
When your home needs heating, cooling, or plumbing help, Cool Air Solutions delivers dependable service with no shortcuts and no surprises. From AC tune-ups and new furnace installations to water heater repairs and leak detection, we provide expert care for every comfort system in your home. Homeowners in Menifee count on us for fast, clean, and honest service, always backed by our unbeatable guarantees.
Need service now? Reach out online or call 951-234-0748 to schedule HVAC or plumbing in Menifee today.
Heating and Cooling Experts in Menifee
We handle all things HVAC with precision and care. Whether you're upgrading to a new energy-efficient AC or your furnace isn’t keeping up, our licensed technicians bring the right tools, the right attitude, and rock-solid craftsmanship to every visit.
- AC installation, repair, and maintenance
- High-efficiency furnace and electric furnace installation
- Ductless mini-splits and zoning systems
- Smart thermostat upgrades
- Seasonal system checkups
- Air balancing and airflow improvements
Every installation comes with our full lineup of guarantees—including our Lifetime Craftsmanship Guarantee, 1-Year Test Drive, No Lemon Guarantee, and No Surprise Pricing. And if your system breaks down unexpectedly, you’re covered by our 24-Hour Fix-It Guarantee—or we pay for your hotel stay.
Licensed Plumber in Menifee, CA
Got a leak, clog, or outdated water heater? Our expert plumbing team is ready to help. We specialize in clean, efficient repairs and system replacements that restore your water flow and peace of mind.
- Water heater repair and replacement (standard and tankless)
- Slab leak detection and pipe repair
- Faucet, shower, and toilet service
- Water softeners and filtration systems
- Pressure regulators and backflow prevention
- Garbage disposals, valves, and fixtures
- Camera inspections and sewer cleaning
Our plumbers show up on time, respect your home, and deliver top-tier results backed by our Lifetime Craftsmanship Guarantee—no cut corners, no compromises.
Affordable Options with Five-Star Results
Cool Air Solutions has earned more than 8,000 five-star reviews by putting homeowners first. We offer honest pricing, flexible financing, and a Comfort Club membership to keep your systems running strong year-round.
- Flat-rate pricing with no hidden fees
- Multiple financing options are available
- Exclusive rebates and energy incentives
- Maintenance plans for better performance and fewer breakdowns
- Licensed, insured, background-checked technicians
From energy-efficient upgrades to emergency repairs, you can count on us to get the job done right—and stand behind it.
Schedule Service in Menifee Today
Experience better comfort, better service, and unbeatable protection on every HVAC and plumbing job in Menifee. Use our online form or call 951-234-0748 to book your appointment now—we’ll be there when you need us.
Recent Jobs and Reviews in Menifee, CA
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and trust. Customers consistently praise the company for delivering professional, knowledgeable, and efficient service. A recurring theme is the technical expertise and personable nature of the technicians, who are described as respectful, friendly, and genuinely passionate about their work. Many reviewers highlight the quality of major installations, including complete HVAC system replacements and ductwork, noting impressive speed and precision even under challenging conditions. The company earns strong appreciation for their transparency, thorough documentation, and clear communication about necessary services versus optional ones. Long-term customer loyalty is evident, with clients expressing continued satisfaction over multiple years and repeated service calls. The responsiveness to inquiries and commitment to standing behind their work further reinforces the positive reputation. Overall, the tone is enthusiastic and grateful, with customers feeling valued and confident in the quality and reliability of the service provided.
Menifee, CA at a glance
Cool Air Solutions has completed 25 jobs in Menifee, CA in September 2022.
The most recent job was on September 13, 2022.
Cool Air Solutions has completed 18 jobs in Menifee, CA in the last 12 months. The first job there was in November 2016.
Our Local Reviews by City
- Aguanga, CA (5)
- Aliso Viejo, CA (1)
- Anaheim, CA (5)
- Banning, CA (2)
- Beaumont, CA (5)
- Bonsall, CA (9)
- Buena Park, CA (2)
- Canyon Lake, CA (27)
- Carlsbad, CA (59)
- Carson, CA (1)
- Cathedral City, CA (1)
- Chino, CA (2)
- Chino Hills, CA (4)
- Chula Vista, CA (13)
- Corona, CA (51)
- Del Mar, CA (3)
- Downey, CA (1)
- Eastvale, CA (1)
- El Cajon, CA (8)
- Encinitas, CA (5)
- Escondido, CA (119)
- Fallbrook, CA (65)
- Fontana, CA (2)
- Fountain Valley, CA (2)
- Fullerton, CA (2)
- Garden Grove, CA (5)
- Hacienda Heights, CA (1)
- Hemet, CA (73)
- Homeland, CA (9)
- Huntington Beach, CA (1)
- Irvine, CA (4)
- Jurupa Valley, CA (2)
- La Verne, CA (1)
- Ladera Ranch, CA (1)
- Laguna Hills, CA (5)
- Laguna Niguel, CA (2)
- Laguna Woods, CA (1)
- Lake Elsinore, CA (119)
- Lake Forest, CA (16)
- Lakeside, CA (5)
- Lakewood, CA (1)
- Lemon Grove, CA (1)
- Los Alamitos, CA (1)
- Menifee, CA (203)
- Mission Viejo, CA (8)
- Moreno Valley, CA (26)
- Murrieta, CA (670)
- Newport Beach, CA (1)
- Norco, CA (3)
- Nuevo, CA (2)
- Oceanside, CA (86)
- Ontario, CA (1)
- Pala, CA (1)
- Pauma Valley, CA (7)
- Perris, CA (24)
- Poway, CA (9)
- Ramona, CA (4)
- Rancho Cucamonga, CA (1)
- Rancho Santa Fe, CA (2)
- Rancho Santa Margarita, CA (2)
- Redlands, CA (4)
- Riverside, CA (36)
- San Bernardino, CA (4)
- San Clemente, CA (1)
- San Diego, CA (81)
- San Dimas, CA (1)
- San Jacinto, CA (28)
- San Juan Capistrano, CA (2)
- San Marcos, CA (48)
- Santa Ana, CA (3)
- Santa Fe Springs, CA (1)
- Solana Beach, CA (1)
- Spring Valley, CA (5)
- Sun City, CA (1)
- Temecula, CA (762)
- Temescal Valley, CA (1)
- Trabuco Canyon, CA (3)
- Upland, CA (2)
- Valley Center, CA (18)
- Vista, CA (161)
- Warner Springs, CA (5)
- Wildomar, CA (77)
- Winchester, CA (125)
- Yorba Linda, CA (14)
- Yucaipa, CA (5)
Job Locations and Reviews
Upon arrival u it was operational. Started at the indoor unit system amps were in range,Temperature split was in range, run cap was in range, blower wheel was dirty and condensation line was cleared. Moved to the outdoor unit checked system pressures they were in range, compressor amps were in range fan amps were way over max amps. Secondary motor control was in range starter was pitted and fan was hot to touch. Washed unit from the inside out and closed it up to present my findings. I explained to the homeowners that they didn’t have a safety switch for there condensation line that will shut the unit off it it overflows, and he starter is getting pitted which happens over time especially with older units, as well as the fan motor is starting to rain which could potential make other components of the unit fail.
Upon arrival indoor motor is bad and needs replacement. Circuit board has a major friend terminal that can eventually cause issues. Client is spending close to 1k a month in electricity bills, with solar. Client wants to get system replaced as soon as possible, tried ordering parts and parts are extremely costly have to follow up with office to adjust pricing. If she decided to do repairs. Client is well aware of what is happening. System is non operational.
Upon arrival indoor motor is bad and needs replacement. Circuit board has a major friend terminal that can eventually cause issues. Client is spending close to 1k a month in electricity bills, with solar. Client wants to get system replaced as soon as possible, tried ordering parts and parts are extremely costly have to follow up with office to adjust pricing. If she decided to do repairs. Client is well aware of what is happening. System is non operational.
Upon arrival indoor motor is bad and needs replacement. Circuit board has a major friend terminal that can eventually cause issues. Client is spending close to 1k a month in electricity bills, with solar. Client wants to get system replaced as soon as possible, tried ordering parts and parts are extremely costly have to follow up with office to adjust pricing. If she decided to do repairs. Client is well aware of what is happening. System is non operational.
Upon arrival indoor motor is bad and needs replacement. Circuit board has a major friend terminal that can eventually cause issues. Client is spending close to 1k a month in electricity bills, with solar. Client wants to get system replaced as soon as possible, tried ordering parts and parts are extremely costly have to follow up with office to adjust pricing. If she decided to do repairs. Client is well aware of what is happening. System is non operational.
Buzzing noise that homeowner is talking about Is actually the compressor. It was talked about on last visit that compressor is working very hard, and I cannot guarantee that it will not give her any issues in the near future. Advised it’s safe to run. Set up thermostat to desired temperatures. System is operational upon departure.
Upon arrival performed diag, system is a very old Goettl system that hangs in side of home. There is no power flowing to system. Clients have a metal piece that runs through that breaker not allowing to let me reset it. Client said previously that when the system kicks on makes the lights turn on and off. Let him know that’s not a very good sign. He is aware. Was able to reset any other switches other then that one that goes to the AC. Mateo to call clients for replacement. Does not know forsure cause they might move. System is non operational.
Upon arrival performed diag, system is a very old Goettl system that hangs in side of home. There is no power flowing to system. Clients have a metal piece that runs through that breaker not allowing to let me reset it. Client said previously that when the system kicks on makes the lights turn on and off. Let him know that’s not a very good sign. He is aware. Was able to reset any other switches other then that one that goes to the AC. Mateo to call clients for replacement. Does not know forsure cause they might move. System is non operational.
Upon arrival performed diag, system is a very old Goettl system that hangs in side of home. There is no power flowing to system. Clients have a metal piece that runs through that breaker not allowing to let me reset it. Client said previously that when the system kicks on makes the lights turn on and off. Let him know that’s not a very good sign. He is aware. Was able to reset any other switches other then that one that goes to the AC. Mateo to call clients for replacement. Does not know forsure cause they might move. System is non operational.
Upon arrival performed diag, system is a very old Goettl system that hangs in side of home. There is no power flowing to system. Clients have a metal piece that runs through that breaker not allowing to let me reset it. Client said previously that when the system kicks on makes the lights turn on and off. Let him know that’s not a very good sign. He is aware. Was able to reset any other switches other then that one that goes to the AC. Mateo to call clients for replacement. Does not know forsure cause they might move. System is non operational.
When I arrived at unit, the condenser fan motor wouldn’t spin. I turned off power and opened condenser cabinet. Checked out motor control and was reading full on both legs. I checked fan motor control and both legs reading 0. That explains why the condenser fan motor wasn’t spinning. After replacing motor control for new one. System took off and started cooling. Starter is black pitted, but owner wants to just replace motor control. Charging for motor control today.
Arrived on site to diagnose no airflow unit. Clustered he just had maintenance and now unit is no longer operational. Arrived. And spoke with client and he stated u it ran fine just stopped blowing air. Cycled unit and unit was operational and ran he still wanted to inspect it. Inspected furnace and electrical compartment and blower motor. Opening up unit and found secondary motor control had got lose and make contact with other metal. Advised may have crated a short and just stopped motor from running then. Secondary motor control is still good. Drain lines are good. Temperature split was at 18 degrees and good l. Filter was replaced. Blower motor was in range of amp and good. Found no repair needed. Just strapped up and secured secondary motor control back in place and unit was operational. Cycled u it and client is happy now unit is cooling and blowing air and is operational. No repairs needed at this time. Collected $29 Dx fee. Unit is operational upon departure.
Upon arrival, furnace panel was not on unit. Put panel on and unit was operational. Gave client option to cancel the call. Client wanted me to inspect unit. Checked out condenser. It’s from 2005. Found compressor dangerously close to over amping and failing. Condenser fan motor is leaking heavy amounts of oil and will fail. Indoor motor is also leaking oil and covered in dirt. Inspection of heater found the heat exchanger is rusting out. System has not been maintained or it has been maintained poorly. Advise client to get it serviced. Client only went forward with the diagnostic and declined maintenance. Unit is operational upon departure.
Performed diagnostic. Richard stated that system is not cooling efficiently as it used to. He said someone came out last year and added refrigerant, and he believes it is low again. They didn’t add anything to try and locate leak at the time. Cycled system on, unit came on and started cooling. Producing a very low temperature split. Gauged up and verified that pressures were indeed low. Also noticed that condenser coil was slightly plugged up. Washed out condenser for accurate pressure readings. Went over findings and recommendations with homeowner. With approval, went ahead and added refrigerant, as well as leak dye. Charged unit up with 3 pounds of r410A to bring unit back to normal operating pressures. Homeowner to call in when unit looses efficiency to perform a leak search.
Performed diagnostic on 22 year old Lennox unit. Met with homeowner, her son in law was also on site. System is not cooling. Cycled system for cooling. Indoor unit kicks on, outdoor unit is completely unresponsive. System is recieving low voltage power, but no high voltage power. Found bad fuses in disconnect box that was not giving the system power. Also found the cause of the bad fuses was due to a bad secondary motor control. Temporarily replaced fuses as well as secondary motor control and cycled system on. Unit came on and started cooling. Gauged up to system and verified proper refrigerant charge. Compressor amp draws are extremely high, and is actually running at its maximum allowed rating. Due to this, compressor could give some issues in the near future that can cause the unit not to cool again. Fan motor is also overworking itself. Overall unit is older and inefficient, and has underlying issues besides the immediate repairs. Went over findings and recommendations with homeo
Client stated no cooling for upstairs -There was no low voltage being sent to the thermostat -I found that the outlet that feeds power to furnace only had 40 volts, instead of the needed 120 volts to power system -The current whip was not long enough to reach the other outlet -I installed a new ship and plugged it into good outlet -System is currently cooling -Fan motor amps are within range, refrigerant levels are within range -Client is now apart of our comfort club maintenance program
Inspected the ducting for damper installation
When I arrived at unit, the condenser unit didn’t sustain keeping house cool. First I hooked up my gauges and checked out pressures in system. Pressures were low, and need of refrigerant. Potential leak in system either in condenser or coil. I then checked amps on my compressor and compressor exceeding max amps. Fan motor also exceeding max amps. Owner is tired of putting money into older system. They would like to speak with supervisor about potential replacement. Appointment today from 5-7 but they are open for early arrival. Today will be charging for diagnostic only today.
Arrived on site to to return for repairs. Client called back and wanted to go forward with recharge of unit. He is aware of it being R-22 and he stated he just wants to charge up to get by summer and e will be getting his finances straight and will call us back to replace. When he can so for now he only did recharge and no dye. He is aware and okay with soo. Advised no guarantee how long unit will hold and he is aware and okay with so. He is aware that we did not fully charge up unit as it still needed another pound but he is okay with leaving it like that. Unit is operational upon departure.
Client stated no cooling -Compressor was locked out thermally due to excessive heat -I cooled it off with the hose to get it unlocked The compressor is unlocked and cooling the house properly
Client was not home rand the doorbell and there was no answer, tried calling twice and both times it went straight to voicemail.
Arrived on site to perform diagnostic on a unit not working. Spoke to to client and he stated his unit was running fine and then just stopped and got loud. Cycled unit fan motor was not operational and compressor was over heating. Shut unit off. Checked components again and found stater good and secondary motor control is good as well advised fan motor is seized up. Now that wife was home went over previously talked about condition and areas of concerns. Advised now that unit is slowly starting to fail now is the time to consider full replacement due to repairs needed and future issues. Clients did want to get someone out but did want to get unit running for now. So got approval to do minimum repairs and if client replace with us we would credit back amount towards unit. Client did want to go forward with that and got on schedule to get someone out. Will be getting Darren out from 4-6 on Thursday 9/8/22 and will be going over replacement options. Installed new motor and got unit opera
Arrived on site to perform spring tune up on a 2004 york unit. Client stated his unit is leaking in attic and froze over condenser. Arrived and spoke with client. He stated after he’s been running unit for a while or his kids unit froze over and saw water leaking from attic and called us out. He stated he’s had repairs done in past and charged up a unit a couple years back. Cycled unit and was operational and not frozen. Unit was operational. Inspected condenser. Fan motor has been leaking oil from years of operation. Primary stater is slight pitted. Secondary motor control out of range and due to unit not being as efficient as it used to and working hard. Advised part will keep getting weak until it fails. Unit hold r-22 and is no longer in production. Found pressure to be low at 40 psig. Advised if he has charged it up in past and is low again unit has a leak present. Inspected attic found black flex ducting used and found to be undersized causing a air flow restriction and not e
Upon arrival unit was operational. Started at the indoor unit amps were in range blower motor was free of oil. Condensation line was clear of debris. Filter was dirty. Moved to the outdoor unit checked systems pressures they were in range amps and secondary motor control were in range. Washed unit from the inside out . Fan was free of oil and spinning freely. Upon departure unit was operational and cooling.
Performed an AC maintenance on a 2015 train system. System was chemically bathed and thoroughly washed. Pressures and temperatures splits were checked and are in range. All electrical components were checked and are in range. Filters were swapped this visit. System is fully operational on time of departure.