Trusted HVAC, Plumbing & IAQ Services in Lake Elsinore—Backed by Unbeatable Guarantees
In a place like Lake Elsinore, where summer temperatures soar and water quality challenges are common, having reliable HVAC and plumbing systems is non-negotiable. At Cool Air Solutions, we provide expert heating, cooling, plumbing, and indoor air quality services designed to protect your comfort, your home, and your budget. Our licensed professionals deliver clean, efficient solutions—all backed by the strongest guarantees in the business.
Need service today? Reach out through our online request page or call 951-234-0748 to book HVAC, plumbing, or IAQ service in Lake Elsinore.
Heating and Air Conditioning in Lake Elsinore
The climate in Lake Elsinore demands reliable cooling in the summer and safe, efficient heating during the cooler months. Our certified HVAC team is here to help you maintain ideal indoor comfort while reducing energy costs and extending system life.
-
AC Repair & Replacement: We repair refrigerant issues, bad compressors, failing fans, and other common problems. Need an upgrade? We’ll install a high-efficiency unit that matches your home and budget.
-
Furnace Installation & Service: We handle safe installation, repairs, and tune-ups for gas and electric furnaces, keeping your home warm and your energy bills under control.
-
Ductless Mini-Splits: These systems are ideal for add-ons, home offices, or multi-zone control and deliver powerful, efficient comfort without ducts.
-
Heat Pumps: Dual-purpose systems that heat and cool efficiently year-round—perfect for Southern California climates.
-
Smart Thermostat Installation: Control your system from your phone, create schedules, and save on utilities with smart thermostat upgrades.
-
HVAC Maintenance Plans: Our seasonal tune-ups help prevent breakdowns, improve airflow, and extend your system’s lifespan.
-
Duct Repair & Airflow Balancing: We diagnose and fix uneven temperatures and noisy ducts by correcting airflow and sealing leaks.
Your installation is protected by our Lifetime Craftsmanship Guarantee, 1-Year Test Drive, No Lemon Guarantee, No Surprise Pricing, and 24-Hour Fix-It Guarantee—we’ll cover your hotel stay if we can’t get your comfort back in a day.
Plumbing Services in Lake Elsinore
Lake Elsinore homes often experience hard water and aging plumbing infrastructure, which can lead to wear and tear over time. Our licensed plumbers offer fast, high-quality solutions that restore performance, improve efficiency, and give you long-term confidence.
-
Water Heater Installation & Repairs: We install and repair both traditional and tankless systems, ensuring your home never runs out of hot water.
-
Slab Leak Detection: Using advanced diagnostic tools, we pinpoint and repair foundation leaks before they cause serious damage.
-
Pipe Repairs & Repiping: Whether it’s a small leak or time to upgrade your piping system, we offer durable solutions with clean workmanship.
-
Toilets, Faucets & Fixtures: We repair or install water-saving fixtures that update your home and cut water waste.
-
Water Softeners & Filtration Systems: Hard water is common in Lake Elsinore—we install systems that improve water quality and protect your plumbing.
-
Sewer Camera Inspections & Drain Cleaning: We find and clear clogs at the source, preventing backups and costly repairs.
-
Garbage Disposal Repairs: Fast, affordable service for jammed, leaking, or outdated disposal units.
-
Backflow & Pressure Regulators: We install devices to protect your water supply and keep your plumbing code-compliant.
All plumbing work is backed by our Lifetime Craftsmanship Guarantee for your complete peace of mind.
Indoor Air Quality (IAQ) Services in Lake Elsinore
From wildfire smoke to dust and allergens, indoor air in Lake Elsinore can quickly become unhealthy. Our IAQ solutions help you breathe easier while improving HVAC performance.
-
Whole-Home Air Purifiers: Remove dust, pollen, bacteria, and VOCs from every room through your HVAC system.
-
High-Efficiency Filters: Extended media filters last longer and trap more airborne contaminants.
-
Humidity Control: Balance dry or damp indoor air with whole-home humidifiers and dehumidifiers.
-
Duct Cleaning & Sealing: Improve indoor air and reduce energy waste with professional duct services.
-
Fresh Air Ventilation Systems: Bring in outdoor air without losing comfort or efficiency.
Why Lake Elsinore Trusts Cool Air Solutions
Thousands of homeowners across Riverside County rely on Cool Air Solutions for comfort that lasts. Here’s what sets us apart:
-
We know local homes. From hard water to high heat, we tailor every solution to your neighborhood’s needs.
-
We work clean. Shoe covers, drop cloths, and spotless cleanup are part of our process, every visit.
-
No-pressure recommendations. We explain your options clearly and let you decide what’s right.
-
Financing options are available. We’ll help you access rebates and flexible payment plans to make upgrades easy.
-
Our guarantees are real. They’re printed, transparent, and honored every time.
Book HVAC, Plumbing, or IAQ Service in Lake Elsinore Today
From fast repairs to energy-saving system upgrades, Cool Air Solutions delivers comfort you can count on—with guarantees you won’t find anywhere else.
Schedule your appointment online or call 951-234-0748 to book your HVAC, plumbing, or air quality service in Lake Elsinore.
Recent Jobs and Reviews in Lake Elsinore, CA
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and trust. Customers consistently praise the company for delivering professional, knowledgeable, and efficient service. A recurring theme is the technical expertise and personable nature of the technicians, who are described as respectful, friendly, and genuinely passionate about their work. Many reviewers highlight the quality of major installations, including complete HVAC system replacements and ductwork, noting impressive speed and precision even under challenging conditions. The company earns strong appreciation for their transparency, thorough documentation, and clear communication about necessary services versus optional ones. Long-term customer loyalty is evident, with clients expressing continued satisfaction over multiple years and repeated service calls. The responsiveness to inquiries and commitment to standing behind their work further reinforces the positive reputation. Overall, the tone is enthusiastic and grateful, with customers feeling valued and confident in the quality and reliability of the service provided.
Lake Elsinore, CA at a glance
Cool Air Solutions has completed 25 jobs in Lake Elsinore, CA between April 2022 and May 2022.
The most recent job was on May 10, 2022.
Cool Air Solutions has completed 12 jobs in Lake Elsinore, CA in the last 12 months. The first job there was in November 2016.
Our Local Reviews by City
- Aguanga, CA (5)
- Aliso Viejo, CA (1)
- Anaheim, CA (5)
- Banning, CA (2)
- Beaumont, CA (5)
- Bonsall, CA (9)
- Buena Park, CA (2)
- Canyon Lake, CA (27)
- Carlsbad, CA (59)
- Carson, CA (1)
- Cathedral City, CA (1)
- Chino, CA (2)
- Chino Hills, CA (4)
- Chula Vista, CA (13)
- Corona, CA (51)
- Del Mar, CA (3)
- Downey, CA (1)
- Eastvale, CA (1)
- El Cajon, CA (8)
- Encinitas, CA (5)
- Escondido, CA (119)
- Fallbrook, CA (65)
- Fontana, CA (2)
- Fountain Valley, CA (2)
- Fullerton, CA (2)
- Garden Grove, CA (5)
- Hacienda Heights, CA (1)
- Hemet, CA (73)
- Homeland, CA (9)
- Huntington Beach, CA (1)
- Irvine, CA (4)
- Jurupa Valley, CA (2)
- La Verne, CA (1)
- Ladera Ranch, CA (1)
- Laguna Hills, CA (5)
- Laguna Niguel, CA (2)
- Laguna Woods, CA (1)
- Lake Elsinore, CA (119)
- Lake Forest, CA (16)
- Lakeside, CA (5)
- Lakewood, CA (1)
- Lemon Grove, CA (1)
- Los Alamitos, CA (1)
- Menifee, CA (203)
- Mission Viejo, CA (8)
- Moreno Valley, CA (26)
- Murrieta, CA (670)
- Newport Beach, CA (1)
- Norco, CA (3)
- Nuevo, CA (2)
- Oceanside, CA (86)
- Ontario, CA (1)
- Pala, CA (1)
- Pauma Valley, CA (7)
- Perris, CA (24)
- Poway, CA (9)
- Ramona, CA (4)
- Rancho Cucamonga, CA (1)
- Rancho Santa Fe, CA (2)
- Rancho Santa Margarita, CA (2)
- Redlands, CA (4)
- Riverside, CA (36)
- San Bernardino, CA (4)
- San Clemente, CA (1)
- San Diego, CA (81)
- San Dimas, CA (1)
- San Jacinto, CA (28)
- San Juan Capistrano, CA (2)
- San Marcos, CA (48)
- Santa Ana, CA (3)
- Santa Fe Springs, CA (1)
- Solana Beach, CA (1)
- Spring Valley, CA (5)
- Sun City, CA (1)
- Temecula, CA (762)
- Temescal Valley, CA (1)
- Trabuco Canyon, CA (3)
- Upland, CA (2)
- Valley Center, CA (18)
- Vista, CA (161)
- Warner Springs, CA (5)
- Wildomar, CA (77)
- Winchester, CA (125)
- Yorba Linda, CA (14)
- Yucaipa, CA (5)
Job Locations and Reviews
Arrived on site and performed AC maintenance on 2016 Lenox unit. Upon arrival Heather stated that the system has been working fine and she has no questions at this time. Preformed full maintenance on outdoor unit And found a point of concern. 1. Starter on outdoor condensing unit is beginning to burn up on contact point due to overworking. This component is responsible for starting the unit and distributing power to both compressor and fan. 2. Condenser coil was heavily covered in dust and debris and recommend that fencing around it is swapped to something with more airflow. 3. Dirty condenser coil is causing compressor to overwork causing starter to burn up. Discussed and presented for maintenance to Heather and she is aware of current condition at this time. She would like discuss with her husband regarding Whole house purification and replacement of the starter outside. Client will also be ordering filters for the future visits. System was reset and tested and is fully operational
Arrived on site to to diagnose a no cooling unit. Tenant stated unit has cooled since she moved in. Found head unit showing code p6 for low pressure switch tripped. Went out side and found outdoor unit not on. Checked valve and checked pressure and found unit to not hold any pressure. Inspected outdoor unit found king valve had a dried up oil. Inspected flare but bolts and found it was really lose. Advised unit leaked out and unknow where but to the the oil spots found advised possibility that it was just lose. Advised would need to charge up and recommended leak dye if it would leak again we can see what is leaking. Client os aware and would just client to recharge up u it and tighten up bolt on flare and use thread sealant to ensure it stays closed. Advised client no guarantee of how long unit will last with just the minimum of a recharge to get it cooling. He is aware of risk and possibilities that can occur in future. He only wanted to do the recharge up and unit is cooling at 20 d
Arrived on site to perform diagnostic on system. Homeowner states he didn’t feel any air flow coming from the vents the other day. System has been working fine but would like it checked. He replaced a couple things on it already himself. Cycled system for cooling. Unit kicked on and started cooling normally. Checked indoor and outdoor unit electrical and system components. Secondary motor controls are in range. Both motors indoor and outdoor are brand new. Cycled system on and off number of times and unit kick on correctly every time. Blower door was loose, and it is very possible that door would disengage the door switch and unit would not kick on. Circuit board could also have an intermittent internal fault. Unit is working correctly at this time so very hard to pin point a issue. System is operational upon departure.
Arrived on air w to perform spring tune up on a 2011 unit. Condenser located on side of home furnace in closet. Client stated no issues and cycled unit. Washed condenser coil inside and out. Primary starter is pitted on points and old. Secondary motor control is out of range on fan as it was as well last year. Recommend replacing. Fan motor is leaking oil and is over amping pulling 1.4 and max at 1.1. Checked start up and run amps on compressor. Run amps pulling 10 and max at 18. Those can go up when it get really hot outside. Recommend a booster kit for compressor to preserve it from a hard start up and stress. Checked pressure and unit is holding charge and cooling hole at 21 degrees. No protection on unit. Filter was dirty and blowers as well. Motor leaking oil from age and past use. Could fail in future. Only has one drain line and not good as there is no safety overflow switch if lines were to get clogged. No protection on I for unit. Cycled unit and not and went over all findings
Ac maintenance on a 2011 Lennox. All pressures are good amperage is god as well. Performed,Ed a chemical wash on the out door unit. Might need to have the capacitor changed at next maintenance. Checked the indoor unit temp split was perfect, amperage was In range. Will need a blower wheel cleaning around the time of next visit.
Installed azure motor and hard start kit.
Call was to evaluate system. Previous companies said the system was leaking refrigerant and should be replaced. Condenser coil is in poor shape. Performed leak search on unit. Found nothing. System was calling for 14 degrees of sub cooling. Currently system is at 5. Could be it wasn’t charged properly upon install. It’s also possible the hole in the condenser coil is messing with the operating pressures. System has a 20 degree temp split. Found no failures during this visit. We will monitor system during maintenance. Unit is operational upon departure.
Arrive on site and performed AC maintenance. Checked indoor unit electrical components and board. Inspected safety and proper venting period filter was clean and did not need to be changed at this time. System was calling at a 20° split. Cleaned outdoor condenser coils and remove debris from bottom of the unit. Inspected contactor and capacitor it is it within range. Inspected indoor blower wheel customer know that it is dirty and does need to be clean for system to be more efficient. System cooling and operational upon departure.
Upon arrival, found 1 5 ton AC. system is 18 years old. Having issues with compressor. Compressor is drawing high amps and almost consuming more power than what it’s rated for. It’s also killing the newly installed capacitor. Refrigerant charge is lower than previous visit. Low super heat indicates low airflow. This system is only getting half Of its rated airflow. Making its super inefficient. Recommend adding additional return ducts. If replacement isn’t an option would recommend replacing compressor. Unit is operational upon departure.
Arrived on site to perform diagnostic on a unknow age unit. Client stated he just got home after father passed away. Heater has not been working. Stated no flame is created. Looks like unit to be original as there’s only heater and no Ac. Cycled unit and it did not turn on. Inspected electrical compartment and wires and cooling but was Receiving power. Jumped fan and it did turn on. Found there to be gas in gas line. Found gas valve to have power. Advised client gas valve is not working. And would have to see if they even make then any more. Client is aware and is going to see what they want to do so nice it really old and may not want to put money into unit. Advised it be better for the client interest to consider system replacement due to the age and unit can start to have more issues in future and repairs made would not have any warranty due to the age of unit. Client is aware and will think it over if he would like replacement options. Unit no operational upon departure and shut
Performed service on a Goodman package unit. The customer Jahl reports his tenants had smoke coming into the home and nothing turns on. I found the blower motor to be blown. Customer will be doing repair himself and wants us to maintenance his system.
Arrived on site to perform tune up on a 2 year old unit. Uniocated on the roof. Client stated no issues and they just replaced filter. Cycled cooling and unit was operational. Washed condenser coil inside and out. Primary starter and secondary motor controls is good and in range. Fan motor is good and free of oil. Checked start and run amps on copper and both motors. All were good and in range. Blower assembly and wheel is good as client is on top of filter change out. Drain lines good. Unit is cooling hole good at 20 degrees. Surge protectors is good as it was added last time. Cycled and unit and went over how u it is running. Unit is operational and cooling upon departure.
Performed AC maintenance. Checked electrical components. Checked filter and replaced. Checked capacitor, it is within range. Checked refrigerant levels they are good. Outdoor condenser coils and remove debris from bottom of condenser. Customer stated she was having issues with the furnace And getting an error message on his nest thermostat. Regarding the flame sensor,checked and cleaned flame sensor as it was dirty. Checked condensate line. Unit is cooling and heating and is operational.
Performed service on a 2012 Amana condenser. Homeowner is new to the home. Reports cooling is not as he believes a AC should cool. Further inspection I found the refrigerant levels to be low. The cooling temperature split is zero. Filter is clean. Indoor coil is clean. No temperature drop between the filter drier. Adding 3lbs of 410 and leak dye with a return visit.
Arrived on site to perform AC diagnostic on 2009 Goodman system. Upon arrival client stated that system has been non operational for over a year. Began diagnostic at thermostat and found that system did not have low voltage power. Proceeded to furnace on side of home and found that system was incorrectly installed. Door which was not properly pushed in, Once pushed in outdoor unit turned on although compressor did not. Inspected electrical components and found that duel secondary motor control was dead on compressor side terminal. Starter had significant burning in pitting on contact points and outdoor motor was leaking oil in beginning to over amp. Condenser coil was also heavily clogged with Dust and debris from not being maintenance. Found that system had a significant amount of air leakage occurring in closet were furnace is located. It was also found at this Manufactured home only has one 10 x 8 return intake. Advise client that refrigerant pressures were a lot lower on suction si
Arrived on site to perform diagnostic on 7 year old Goodman unit. Homeowner states that system is not cooling. It is blowing air but it’s just not blowing cold air. Desmond replaced the filters because they were extremely hammered. Cycled system for cooling. Indoor unit turns on normally. Outdoor unit turns on, but compressor is not kicking on. Checked unit electrical and system components. Found a bad secondary motor control that was not allowing the compressor to turn on. Put in a temporary secondary motor control and cycled unit. Compressor kicked on and started cooling. Refrigerant pressures are in range and system is producing proper temperature split. Outdoor condenser unit coil is very dirty, unit has never been maintained. Primary motor control is burnt and pitted. Went over findings and recommendations with Desmond, and with wife over the phone. Approved middle repair as well as signing up on maintenance program. Replaced primary and secondary motor controls. Pulled condense
Upon arrival found outdoor system not operational. Found the low voltage wires in the condenser were switched. Fixed it and the unit began to cool. Tested system. Found both caps low and out of range. Compressor amps were high. Almost at max. Made recommendations for repairs. Client choose replacement.
Upon arrival started combo tune up. Cleaned outside coil and checked refrigerant charge. Temp split is good. Airflow restriction is high. Checked indoor furnace. System is uperstionsl upon departure.
Upon arrival performed combo tune up. Tested all electrical. Ducts are falling apart and causing airflow issues and poor system performance.
Upon arrival performed maintenance on air conditioning system. Same recommendations as last time, blower wheel is extremely dirty still, only getting worse. Indoor secondary motor control is out of range. Outdoor contractor is pitted & burned on contacts. Amperage’s and motors are in range. Washed out condenser coil. Replaced filter client provided. Highly recommend blower wheel cleanings & upgrading system to 5 inch filters. System is operational upon completion.
Upon arrival performed maintenance on air conditioning system. Same recommendations as last time, blower wheel is extremely dirty still, only getting worse. Indoor secondary motor control is out of range. Outdoor contractor is pitted & burned on contacts. Amperage’s and motors are in range. Washed out condenser coil. Replaced filter client provided. Highly recommend blower wheel cleanings & upgrading system to 5 inch filters. System is operational upon completion.
Upon arrival performed maintenance on air conditioning system. Same recommendations as last time, blower wheel is extremely dirty still, only getting worse. Indoor secondary motor control is out of range. Outdoor contractor is pitted & burned on contacts. Amperage’s and motors are in range. Washed out condenser coil. Replaced filter client provided. Highly recommend blower wheel cleanings & upgrading system to 5 inch filters. System is operational upon completion.
Upon arrival performed maintenance on air conditioning system. Same recommendations as last time, blower wheel is extremely dirty still, only getting worse. Indoor secondary motor control is out of range. Outdoor contractor is pitted & burned on contacts. Amperage’s and motors are in range. Washed out condenser coil. Replaced filter client provided. Highly recommend blower wheel cleanings & upgrading system to 5 inch filters. System is operational upon completion.
Arrived on site to perform AC diagnostic on 2006 Goodman condensing unit. Upon arrival Mrs. Edwards stated That system stopped working unexpectedly yesterday and is no longer blowing cold air out of the vents. They have recently just moved and had no issues until now, Prior to buying the house they were not told anything regarding the system other than it works. During my troubleshooting I found a major terminal fault within the system. The heart of the system which pumps refrigerant into the evaporator coil in the attic to cool the house is called the compressor and it has failed unfortunately. Here is a breakdown of my main findings and potential failure points. 2.5 ton upstairs condenser (GOODMAN) 1. Found that dual secondary motor control that powers compressor and fan was out of range which was the first things that we replaced to try to get the system up and running. This component had gone out due to the compressor over amping. 2. New duel secondary motor control was installed
Performed combo maintenance given with install. Cleaned head units and checked temperature splits. Outdoor unit was washed. All systems are performing as designed. Filters were cleaned. System is operational at end of appointment.