Comfort Starts Here—Heating, Cooling & Plumbing for Winchester Homes and Businesses
Looking for dependable HVAC or plumbing services in Winchester, CA? Cool Air Solutions is your local source for fast, affordable home comfort solutions. Whether you're battling the summer heat, facing a mid-winter chill, or dealing with an unexpected leak, our expert team is just around the corner—and ready to help.
Since 2006, we’ve been helping homeowners in Winchester stay comfortable year-round with precision heating, cooling, and plumbing services. From AC installations to water heater repairs, we handle it all with unmatched craftsmanship and backed-by-our-promises service.
Use our online form or call 951-234-0748 to schedule your service today.
Heating and Air Conditioning in Winchester, CA
Professional HVAC Services for Every Season
Don’t leave your home comfort to chance. Our certified HVAC technicians deliver responsive service and expert solutions, whether you need a seasonal tune-up or a full system replacement. We service all major brands and specialize in high-efficiency installations that save energy without sacrificing performance.
Our HVAC services include:
-
AC installation, replacement & repair
-
Furnace repair & electric furnace installation
-
Smart thermostat upgrades
-
Ductless mini-split systems
-
Heat pumps & hybrid systems
-
Seasonal tune-ups and precision maintenance
-
Airflow balancing and zoning solutions
Every installation comes with our Lifetime Craftsmanship Guarantee, 1-Year Test Drive Guarantee, and No Surprise Pricing. And if your system ever breaks down unexpectedly, we’ve got your back with our 24-Hour Fix-It Guarantee.
Plumber in Winchester, CA
Plumbing Problems? One Call Solves Them All.
When plumbing issues strike, Cool Air Solutions is ready to respond with fast, professional service. Whether it’s a worn-out water heater or a mystery leak behind your wall, we’ll get to the root of the problem and deliver a lasting fix—no mess, no stress.
Our plumbing services in Winchester include:
-
Water heater repair and installation (tank and tankless)
-
Slab leak detection and repair
-
Pipe and valve replacement
-
Toilet, faucet, and shower repairs
-
Garbage disposal service
-
Water filtration and softener systems
-
Pressure regulators and backflow devices
-
Sewer inspection and hydro-jetting
Our licensed plumbing team handles each job with care, using the right tools, the right parts, and the right attitude. No subcontractors. No shortcuts. Just clean, reliable results backed by our Lifetime Craftsmanship Guarantee.
Affordable Comfort, Trusted Service
At Cool Air Solutions, we believe quality should never come with sticker shock. That’s why we offer:
-
Transparent pricing with no upsells
-
Flexible financing options
-
Top-tier systems from trusted brands like Lennox
-
Access to local and federal rebates and incentives
-
Optional Comfort Club membership for year-round maintenance
Our technicians arrive on time, protect your home during every visit, and take the time to explain your options, so you can make the best decision for your home and budget.
Schedule HVAC or Plumbing Service in Winchester Today
Whether you need a quick fix or a total system upgrade, Cool Air Solutions is here to help. We're proud to provide heating, air conditioning, and plumbing services to homeowners across Winchester and the surrounding areas.
Contact us online or call 951-234-0748 to book your appointment today and experience the comfort and care you deserve.
Recent Jobs and Reviews in Winchester, CA
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and trust. Customers consistently praise the company for delivering professional, knowledgeable, and efficient service. A recurring theme is the technical expertise and personable nature of the technicians, who are described as respectful, friendly, and genuinely passionate about their work. Many reviewers highlight the quality of major installations, including complete HVAC system replacements and ductwork, noting impressive speed and precision even under challenging conditions. The company earns strong appreciation for their transparency, thorough documentation, and clear communication about necessary services versus optional ones. Long-term customer loyalty is evident, with clients expressing continued satisfaction over multiple years and repeated service calls. The responsiveness to inquiries and commitment to standing behind their work further reinforces the positive reputation. Overall, the tone is enthusiastic and grateful, with customers feeling valued and confident in the quality and reliability of the service provided.
Winchester, CA at a glance
Cool Air Solutions has completed 25 jobs in Winchester, CA between April 2022 and June 2022.
The most recent job was on June 10, 2022.
Cool Air Solutions has completed 11 jobs in Winchester, CA in the last 12 months. The first job there was in November 2016.
Our Local Reviews by City
- Aguanga, CA (5)
- Aliso Viejo, CA (1)
- Anaheim, CA (5)
- Banning, CA (2)
- Beaumont, CA (5)
- Bonsall, CA (9)
- Buena Park, CA (2)
- Canyon Lake, CA (27)
- Carlsbad, CA (59)
- Carson, CA (1)
- Cathedral City, CA (1)
- Chino, CA (2)
- Chino Hills, CA (4)
- Chula Vista, CA (13)
- Corona, CA (51)
- Del Mar, CA (3)
- Downey, CA (1)
- Eastvale, CA (1)
- El Cajon, CA (8)
- Encinitas, CA (5)
- Escondido, CA (119)
- Fallbrook, CA (65)
- Fontana, CA (2)
- Fountain Valley, CA (2)
- Fullerton, CA (2)
- Garden Grove, CA (5)
- Hacienda Heights, CA (1)
- Hemet, CA (73)
- Homeland, CA (9)
- Huntington Beach, CA (1)
- Irvine, CA (4)
- Jurupa Valley, CA (2)
- La Verne, CA (1)
- Ladera Ranch, CA (1)
- Laguna Hills, CA (5)
- Laguna Niguel, CA (2)
- Laguna Woods, CA (1)
- Lake Elsinore, CA (119)
- Lake Forest, CA (16)
- Lakeside, CA (5)
- Lakewood, CA (1)
- Lemon Grove, CA (1)
- Los Alamitos, CA (1)
- Menifee, CA (203)
- Mission Viejo, CA (8)
- Moreno Valley, CA (26)
- Murrieta, CA (670)
- Newport Beach, CA (1)
- Norco, CA (3)
- Nuevo, CA (2)
- Oceanside, CA (86)
- Ontario, CA (1)
- Pala, CA (1)
- Pauma Valley, CA (7)
- Perris, CA (24)
- Poway, CA (9)
- Ramona, CA (4)
- Rancho Cucamonga, CA (1)
- Rancho Santa Fe, CA (2)
- Rancho Santa Margarita, CA (2)
- Redlands, CA (4)
- Riverside, CA (36)
- San Bernardino, CA (4)
- San Clemente, CA (1)
- San Diego, CA (81)
- San Dimas, CA (1)
- San Jacinto, CA (28)
- San Juan Capistrano, CA (2)
- San Marcos, CA (48)
- Santa Ana, CA (3)
- Santa Fe Springs, CA (1)
- Solana Beach, CA (1)
- Spring Valley, CA (5)
- Sun City, CA (1)
- Temecula, CA (762)
- Temescal Valley, CA (1)
- Trabuco Canyon, CA (3)
- Upland, CA (2)
- Valley Center, CA (18)
- Vista, CA (161)
- Warner Springs, CA (5)
- Wildomar, CA (77)
- Winchester, CA (125)
- Yorba Linda, CA (14)
- Yucaipa, CA (5)
Job Locations and Reviews
Technician arrived to perform spring tune up -Condenser was thoroughly cleaned out and debris was removed -Refrigerant levels were within range -The Condenser fan motor and compressor are in bad condition. -The fan motor is maxed out amps (.93/1) and is rusted out, cracking, and leaking oil, which is a sign when the motor is dying -The compressor struggle to start up, it is maxed out on amps as well at (18/18) and is drawing a lot of power -The system is 23 years old and if the client wants to get the most out of it, the fan motor, a compressor saver kit, and a new secondary motor control are definitely recommended -The system is doing it job and cooling, but it is doing it very inefficiently and needs some repairs
Upon arrival started installing new fan motor and capacitor. Cut fan motor shaft to length. Wired with new connectors. Installed capacitor. Tested system and verified proper rotation. Unit is operational upon departure. 1 year parts/labor warranty.
Arrived on site to perform diagnostic on unit. Upstairs unit is not cooling. Everything is running but it is just not dropping in temperature. Cycled system for cooling. Unit kicked on. Unit is not producing any temperature split or cooling effect at all. Checked outdoor unit electrical and system components. Compressor is short cycling on and off, all electrical is in proper range. Gauged up to system and found system to be basically flat on refrigerant, low side is actually going into a vacuum mode. Compressor is short cycling due to no lubrication and running hot. Evaporator coil is completely sealed with pookie and pookie tape and cannot be opened without using extreme force to perform pressure check. No signs of oil or refrigerant leak at outdoor condenser. Went over findings and recommendations with homeowner. Also mentioned that at one point there was water leaking from ceiling but then stopped. It is more than likely that system iced up from being low on refrigerant and water l
Upon arrival, found a 6 year old condenser and 8 year old furnace. 3 ton single staged zoned system. Went to the condenser and checked electrical. The capacitor had been replaced. Charge is good. Compressor amps are okay. Fan motor amps are good. Cleaned condenser coils. Temp split was off. 13/20. Found static pressure to be off the charts high. Airflow is super restricted. Return ducts should be increased in sized or add another one. But, space is limited in attic. Informed client on options. Will look into more long term solutions with service manager. System is operational upon departure.
Performed AC maintenance on heat pump. Inspected unit and found transformer to be pitted. I highly recommend this component to be replaced. Tested capacitor as weak and should also be replaced. Washed condenser coils. Unable to check filter as it was inaccessible-tenants bed was under filter grill. This unit does not have surge protection. System is cooling and operational upon departure. Unable to get a hold of the homeowner for recommended repairs will follow up with homeowner in a few days
Performed city inspection via zoom with riverside county.
Upon arrival, client said original issue had gotten worse. Water was still coming out from the secondary line out the side of the house. First diagnostic seemed the drain lines were not installed right from the original install. This turned out to be wrong. Found the primary pan to be cracked. Informed client. Because of circumstances, credit back original repair towards the cost of the drain pan replacement.
Upon arrival started tune up on both systems. Systems are operational. Having same issues as previous visit but they are getting worse and affecting other components. Mainly the upstairs system. The condenser fan motor is failing. Will most likely fail with the summer heat. This stress is making the compressor fail. Both are using high motor amps. Cleaned both condenser coils and checked electrical. Found capacitor on upstairs system out of range. This will fail this summer. Recommend replacing it to avoid other electrical failures. Change is good on both systems. Made detailed recommendations. Systems are operational upon departure.
Arrived on site. Client said unit would drain out secondary drain. Found condensate line to be installed incorrectly, and it was clogged. Retrofitted drain line and cleaned it out. Cleaned out under the sink. Installed flood protection system. Clients signed up on maintenance program. Unit is operational upon departure.
Arrived on site and performed AC maintenance on two systems aireflo condensers from 2006. Upon arrival Ryan stated they just moved in in November and signed up on the maintenance plan to keep Up on maintenance and Keep system at standard. Performed fall maintenance on outdoor unit. Finds- Upstairs- 1. Outdoor condensing fan motor had significant oil leak is coming from its bearing which can result in at locking up or over heating. 2. Dual secondary motor control has become weak and out of range 3. Starter is significantly burned on contact points and can result on failure for start up. 4. System contained R22 refrigerant which was phased out 2020 5. Recommend compressor saver kit is installed to reduce startup amperage and increase longevity for compressor 6. System is not equipped with surge protection in the case of a power surge. 7. Indoor blower motor had oil leakage occurring as well and can result in failure and heating and cooling if this worsens Downstairs- 1. Starter was signi
Upon arrival performed maintenance on AC system. On brand new Xp20. Indoor motor and wheel in very good condition. Circuit board and electrical connections good. Ducting in very good condition. Condenser coils were cleaned completely. Amperage’s & voltages in range. System is operational upon completion.
Upon arrival performed maintenance on AC system. On brand new Xp20. Indoor motor and wheel in very good condition. Circuit board and electrical connections good. Ducting in very good condition. Condenser coils were cleaned completely. Amperage’s & voltages in range. System is operational upon completion.
Upon arrival performed maintenance on AC system. On brand new Xp20. Indoor motor and wheel in very good condition. Circuit board and electrical connections good. Ducting in very good condition. Condenser coils were cleaned completely. Amperage’s & voltages in range. System is operational upon completion.
Upon arrival performed maintenance on AC system. On brand new Xp20. Indoor motor and wheel in very good condition. Circuit board and electrical connections good. Ducting in very good condition. Condenser coils were cleaned completely. Amperage’s & voltages in range. System is operational upon completion.
Perform for AC maintenance. Checked and tightened electrical components. Inspected ducting for proper airflow made sure everything was connected and they were No sinks in the ducting. Measure temperature split at 20°. System has zoning. Inspected proper balance of indoor blower wheel. Inspected condensate lines. Clean outdoor coil remove debris from the bottom of the unit. Tested capacitor it is within range. Inspected outdoor fan motor and measured amperage. Checked filters customer had just changed last week. System does not have search protection for float switch on drain pan. System is cooling and operational upon departure.
Arrived on site and found that jumper was placed between B And R causing the system to stay stuck in heating mode. Removed jumper and system is cooling properly upon departure.
Inspected the system for operation and diagnosed drain issue.
Arrived on site to perform AC diagnostic on 13-year-old Maytag condensing unit for manufactured home. Upon arrival Diana stated that her husband is in the hospital and needs to get the system working properly before he comes home. She states that the company that originally installed the system is not honoring their lifetime warranty and will no longer service the unit. Began diagnostic at thermostat and found that the Thermostat was defective. Proceeded to furnace and found a very strong propane smell admitting from the gas valve. Shut gas valve off for the meanwhile until this problem is addressed in the future. Filter was heavily caked and extremely restrictive which has resulted in the air mixing cabinet becoming covered in dust and debris. Indoor blower motor is leaking oil from its bearing and is moving less air capacity across the evaporator coil due to it overworking over the years. Proceeded to outdoor unit and found that it was operational although the duel secondary motor co
The total job in 17707. Customer will pay 14707 and cal tech California will pay 3000
1 - 3 and 1 - 4ton ton furnace coil and condensers x-series System totals out to $26,843.00.00- client is only liable for payment of $20,843.00as Tech clean California rebate will cover $6000.00 balance.
Arrived on site to perform AC maintenance on 2004 Bryant condensing unit. Upon arrival Shane states that he just moved in approximately two months ago and he’s doing this maintenance to verify the condition of his system. Performed full maintenance And discovered multiple faults within the system that will lead to failure. 1. Measured refrigerant pressures and found that there is a restriction within the unit. This is resulting in a pressure imbalance in the which Causing the compressor to overwork putting in at a very high risk of failing lack of efficiency. 2. Dual secondary motor control is Weak And causing the compressor to overwork. 3. Outdoor condensing fan motor and indoor blower above leaking oil from its bearing 4. Starter showed signs of pitting and burn marks on contact points. 5. Static pressure is lower than usual due to blower motor slowing down in speed from oil loss 6. System contains R22 which was completely phased out January 1, 2020 Discussed full maintenance with
System qualifies for promotional financing: Reduced apr at 102 per month or 18 months no payments no interest Total job is 12987. Amount to be collected will be 9984. Amount paid to us by the cal tech California rebate program will be $3000
Performed AC maintenance on a pair of Carrier Condensers. Customer Reports frequent usage of the system in the summertime. Both units started with no issue. System has had repairs done in the past. Condenser fan motors Are significantly leaking oil, this can cause interruption during heavy usage. Outdoor units were chemically cleaned. Starting components were measured and tested. Outdoor amp draws are in range on both units. Refrigerant levels are OK. Indoor amp draws are OK. Cooling temperature split are in range for both units. Customer is aware of the condition. Systems are operational.
Upon arrival performed maintenance on AC system. System is older and is running high in electrical but is still below manufactured specs. Secondary motor control is in range. Indoor blower wheel is extremely dirty . Primary drain was clogged at p trap and at bottom of sink. Re worked drains, and added safety switch. System is now draining correctly. Primed drain with half a gallon of water. Refrigerant levels in range. Client replaced his filter. No models or serials, rubbed off. Client has a big hole in ducting might have a rat problem.
Upon arrival performed maintenance on AC system. System is older and is running high in electrical but is still below manufactured specs. Secondary motor control is in range. Indoor blower wheel is extremely dirty . Primary drain was clogged at p trap and at bottom of sink. Re worked drains, and added safety switch. System is now draining correctly. Primed drain with half a gallon of water. Refrigerant levels in range. Client replaced his filter. No models or serials, rubbed off. Client has a big hole in ducting might have a rat problem.