financing Special Offers Call Us Book Online

Wildomar, CA

Local HVAC and Plumbing in Wildomar, Backed by the Area’s Best Guarantees

When it comes to home comfort in Wildomar, Cool Air Solutions is the name locals trust for responsive HVAC and plumbing service done right. Whether you're sweating through an AC breakdown, dealing with low water pressure, or considering an energy-efficient upgrade, our licensed professionals bring the tools, training, and care needed to restore your peace of mind. We’ve been serving Wildomar homeowners since 2006—and every service call is backed by the most trusted guarantees in the region.

Need fast service? Send us a message online or call 951-234-0748 to schedule your HVAC or plumbing appointment in Wildomar.

Wildomar Heating and Air Conditioning Services

The Wildomar climate demands reliable heating and cooling. Our certified HVAC techs specialize in systems that keep your home comfortable year-round, while also helping you reduce energy costs. From tune-ups to total replacements, we’re here to make sure your system runs efficiently and quietly when you need it most.

  • High-efficiency AC installation and repair

  • Gas and electric furnace replacement and service

  • Smart thermostats and zoning system upgrades

  • Ductless mini-split systems for flexible comfort

  • Heat pump installations for all-electric heating and cooling

  • Seasonal HVAC maintenance and inspections

  • Airflow correction and duct diagnostics

All HVAC services and system installations come with our signature protections, including the Lifetime Craftsmanship Guarantee, 1-Year Test Drive, No Lemon Guarantee, No Surprise Pricing, and our exclusive 24-Hour Fix-It Guarantee—covering a hotel stay if we can’t restore your comfort within a day.

Wildomar Plumbing Services

A plumbing problem can stop your day in its tracks—but we’re here to get things flowing again. Our licensed plumbers handle everything from urgent repairs to modern upgrades. Whether it’s a slab leak, faulty water heater, or outdated fixtures, you’ll get fast, professional service with clean results and lasting value.

  • Tank and tankless water heater repair and installation

  • Leak detection and slab leak repair

  • Faucet, toilet, and shower installations

  • Garbage disposal repair and replacement

  • Water filtration and softener systems

  • Pressure regulators and backflow devices

  • Sewer camera inspections and hydro-jetting

  • Pipe repair and repiping services

Every plumbing job is backed by our Lifetime Craftsmanship Guarantee—because plumbing done right means you never have to think about it again.

Why Homeowners in Wildomar Choose Cool Air Solutions

With so many companies to choose from, we stand out by doing more than just fixing your system—we focus on the whole experience. Here’s what makes us the go-to choice for HVAC and plumbing in Wildomar:

  • Responsive service, no runaround. We show up when we say we will and keep you updated every step of the way.

  • Trained, background-checked professionals. Our techs and plumbers are employees, not subcontractors—fully licensed and fully accountable.

  • Clear options, no pressure. We take time to explain your repair and replacement options, then let you decide what works best.

  • Clean work, guaranteed. We treat your home with respect and leave it better than we found it.

  • Financing and rebates. We help you take advantage of rebates and offer flexible financing options to make upgrades more affordable.

Thousands of five-star reviews prove we don’t just talk about great service—we deliver it.

Book Plumbing or HVAC Service in Wildomar Today

Your home deserves year-round comfort and long-lasting systems, without stress or surprises. From AC repairs to plumbing upgrades, Cool Air Solutions has your back. 

Book your visit online or call 951-234-0748 to schedule HVAC or plumbing service in Wildomar today.

Recent Jobs and Reviews in Wildomar, CA

Rated 4.9 out of 5 stars based on 77 customer reviews

Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and trust. Customers consistently praise the company for delivering professional, knowledgeable, and efficient service. A recurring theme is the technical expertise and personable nature of the technicians, who are described as respectful, friendly, and genuinely passionate about their work. Many reviewers highlight the quality of major installations, including complete HVAC system replacements and ductwork, noting impressive speed and precision even under challenging conditions. The company earns strong appreciation for their transparency, thorough documentation, and clear communication about necessary services versus optional ones. Long-term customer loyalty is evident, with clients expressing continued satisfaction over multiple years and repeated service calls. The responsiveness to inquiries and commitment to standing behind their work further reinforces the positive reputation. Overall, the tone is enthusiastic and grateful, with customers feeling valued and confident in the quality and reliability of the service provided.

Wildomar, CA at a glance

Cool Air Solutions has completed 25 jobs in Wildomar, CA between June 2021 and August 2021.

The most recent job was on August 10, 2021.

Cool Air Solutions has completed 8 jobs in Wildomar, CA in the last 12 months. The first job there was in November 2016.

Our Local Reviews by City

Job Locations and Reviews

Madison H.
Madison H. Checked in
Tech arrived on site. Found the capacitor had failed. While servicing the unit, the fuse box for the disconnect fell out of the box breaking it. Replaced disconnect and the unit has proper voltage. Client declined repairs at this time since he’s able to do the repairs himself.
Wildomar, CA 92595
Daniel T.
Daniel T. Checked in
Performed AC maintenance on a Day and night system. Units cooling temperature split is 20 degrees. Condensate lines are clear. Indoor motor is leaking oil but amping in range. Filter is ok. Outdoor unit was chemically cleaned. Fan motor is leaking oil but spinning ok. Compressor start amps are in range. The starter is showing serious signs of wear, recommending replacement. System was running st end of appointment.
Wildomar, CA 92595
Jorge C.
Jorge C. Checked in
Performed diagnostic on 2012 Goodman unit. Homeowner states system is cooling, but it has never reached below 82 degrees and wants to see if there’s a reason for that. Had the system installed in 2012 by his friend, system cools but can never do below 82 degrees. Performed thorough evaluation of system. Concerns are as follows: 1. Compressor is over amping. Compressor is rated for 19 amps and is pulling 21. 2. Secondary motor control for both compressor and condenser fan motor is weak. Still starting up but has fallen way below the range. 3. Primary motor control is burnt and pitted. 4. Furnace to coil transition is fairly restrictive 5. Ductwork is poorly designed and has kinks through out. 6. System is a 5 Ton unit operating on only one 20x30x1 return register. 7. Insulation levels are low and quality is very poor. 8. Windows are all single Pane windows. Went over findings and recommendations with homeowner. Went over maintenance program as well. Homeowner would like everyth
Wildomar, CA 92595
Daniel T.
Daniel T. Checked in
Performed AC maintenance on a Lennox system. The cooling temperature split is over 20 degrees. Duct runs are sealed. Condensate lines are clear and flowing ok. Primary blower is clean and amping in range. Filter was changed today. Outdoor unit had serious amount of dirt and hair build up. It was chemically cleaned today. Customer reported loud noise upon startup and wanted to have his compressor assist kit unwired to see if it will help. This was done and did not have a significant change to the noise. I noticed the lines that cover was vibrating on startup that is probably causing the noise. I added a few screws to help the vibration. The noise is still occurring. Compressor and fan amperage are ok. Refrigerant levels are ok. Indoor and outdoor units have no protection. System was running at end of appointment
Wildomar, CA 92595
Michael P.
Michael P. Checked in
Thermostat showing error to communicate arrival. The circuit board is showing a code of “124” lost communication with main thermostat for more than 3 minutes. Grounded extra low voltage wiring and reset system. System is working properly at this time.
Wildomar, CA 92595
Luis M.
Luis M. Checked in
Upon arrival performed diagnostic on hvac system. Client said he was getting water backed up, he cut primary drain and found the clog. Cleared it out,signed client up with membership, client is putting all pvc back together himself.
Wildomar, CA 92595
Luis M.
Luis M. Checked in
Upon arrival performed diagnostic on hvac system. Client said he was getting water backed up, he cut primary drain and found the clog. Cleared it out,signed client up with membership, client is putting all pvc back together himself.
Wildomar, CA 92595
Luis M.
Luis M. Checked in
Upon arrival performed diagnostic on hvac system. Client said he was getting water backed up, he cut primary drain and found the clog. Cleared it out,signed client up with membership, client is putting all pvc back together himself.
Wildomar, CA 92595
Luis M.
Luis M. Checked in
Upon arrival performed diagnostic on hvac system. Client said he was getting water backed up, he cut primary drain and found the clog. Cleared it out,signed client up with membership, client is putting all pvc back together himself.
Wildomar, CA 92595
Jimmy P.
Jimmy P. Checked in
Performed a leak dye search on 2013 Aireflo condenser. Upon my search client stated that system has been cooling fine and hasn’t noticed any change yet. Started search at outdoor unit and found that the condenser coil had significant coil rot on the aluminum part of it. This was caused by the dogs urinating on it overtime Alice potentially make this a red flags on for a leak. On the outdoor unit found no leaks present and verified the refrigerant pressures were holding up as of this second. Proceeded to evaporator coil an attic to find that it had multiple leaks. Found that the 5 year warranty is no longer available for the evap coil. Coil will need to be replace to prevent any further leakage and refrigerant loss. Also performed AC maintenance as of now this is one of two visits. Supervisor will be contacting Xavier regarding his options. Upon departure leak was found and maintenance was done
Wildomar, CA 92595
Daniel T.
Daniel T. Checked in
Performed AC maintenance on a American standard system. Units cooling temperature split is over 20 degrees. Condensate line is clear and equipped with a safety switch. Primary blower is amping in range. Blower fins are dirty. Primary start component for the blower is out of range. Filter was washed today. Outdoor unit was chemically cleaned. UV protection was applied today. Compressor start amps are high for this unit. Fan is amping in range and free of any oil leakage. System was running at the end of the appointment
Wildomar, CA 92595
Jimmy P.
Jimmy P. Checked in
Performed AC diagnostic on year 2000 and Lennox condenser. Upon my diagnostic homeowner son was only one present and he stated that the system just stopped working a couple days ago and is no longer cooling. Upon my diagnostic I found a major terminal fault in their system. 1. Found a Condenser high-voltage wires connected to starter were completely burnt up and Crisp due to the high amperage pull of the heart of the system. 2. The compressor is only design for 26 A and is using a total of 27 to 30 A run time and even exceeding this due to the amount of wires that are burnt up. Homeowner even stated that the breaker that tripped previously prior to calling me due to the compressor using too much power 3. Starter had significant burning on contact points and on compressor wire lugs 4. R22 refrigerant levels were low as well due to a leak somewhere within the refrigeration cycle Discussed the full condition of the system with homeowner over the phone. Homeowner was suspicious of me tryi
Wildomar, CA 92595
Daniel T.
Daniel T. Checked in
Performed AC maintenance on a Bryant system. Systems cooling split is 23 degrees. Duct runs are sealed. Indoor blower is clean. Indoor motor is not leaking oil at this time. Primary start component is failed and out of range. Condensate lines are clear but has no safety switch. Outdoor unit was cleaned. Compressor bay and service panel were cleaned. Electrical components are in range. Compressor and fan amps are ok. Refrigerant levels are ok. System was cycled before leaving.
Wildomar, CA 92595
Jorge C.
Jorge C. Checked in
Performed Ac maintenance on (2) 1 year old Lennox systems. Replaced Merv 11 filters provided by homeowner. Temperature splits are in range for both systems, refrigerant pressures are good. Checked outdoor unit electrical and system components. Primary motor controls are in good condition. Secondary motor control for right side unit had a bad fan reading, replaced under warranty. Pulled condenser fan motors off and thoroughly washed out condenser coils inside and out. Went over findings and recommendations. Homeowner liked the idea of adding whole home air purification to systems. Needs to talk it over before making a decision. Cycled systems, systems are operational upon departure.
Wildomar, CA 92595
Jimmy G.
Jimmy G. Checked in
Arrived on site to perform spring tune on a 2013 Goodman unit. Condenser located in back. Furnace and Evaporator coil located in outdoor closet. Cycled unit. Washed condenser coil inside and out. Checked electrical compartment. Primary starter was a bit worn out due to age and normal operation. Secondary motor control was good in range. Fan motor was good and amp were in range. Checked pressure and are good and cooling hole at 22 degrees. Inspected indoor unit. Furnace really dusty due to being in a Outdoor closet and where home is surrounded by. Found 2 flyer used and advised that is not good and should only have one filter to prevent airflow restriction. Left one filter in furnace and was replaced. Blower assembly is dirty. Motor is good and secondary control as well. Drain line has no safety overflow switches. System is cooling at 22 degrees. Cycled system to ensure system operating. Went over all findings with client. Client is aware of how system is running and it’s condition. C
Wildomar, CA 92595
Jimmy G.
Jimmy G. Checked in
Arrived on site to replace oem blower motor and secondary motor control. Replaced and cycled units. Both indoor and out door units are operational and cooling. System is operational and cooling upon departure. Parts will only have warranty for 90 days. Recommend adding surge protectors on units to protect from electrical surge protectors and power outages.
Wildomar, CA 92595
Jimmy G.
Jimmy G. Checked in
Arrived on site to diagnose a no cooling unit. Found unit to be From 2013. Furnace is original to home. Upon arrival client cycled system and was operational. Found that condenser was replaced but evaporator coil was not by a family friend. Client stated unit will run and then stop cooling. Inspected out door unit found secondary dead and why spun it was not cooling. Primary starter was burnt up. Start up amp we’re at max. Recommend replacing starter and adding a compressor booster kit to help lower startups. Fan motor is over amping and could fail at any time. Recommend replacing as bad motor can cause secondary motor to fail again. Pressure were in range and cooling home at 20 degrees.inspected indoor unit and is original to home. Found evaporator coil was never replaced and could be really dirty due to no filter rack to hold filter down. Drain lines are dirty and only one is in use. Found also drywall base of furnace furnace had big black spot of what look to be biological
Wildomar, CA 92595
Darren F.
Darren F. Checked in
Quality control check
Wildomar, CA 92595
Jimmy G.
Jimmy G. Checked in
Arrived on site to diagnose a no cooling unit from 2007 trane unit. Client stated she just had it serviced and and unit is not working. Cycled unit. Indoor unit was no producing airflow and out door unit didn’t sound like compressor was running. Inspected indoor unit. Jumped from board and thermostat. Found power coming in and going out with 24v and 120v. Found motor was not turning on and 120 voltage was getting to motor overall found a bad motor. Advised since unit is not working unable to inspect out door unit with out it working inside. Would have to replace motor to ensure no other issues are present. Due to weekend unable to get price of motor so would have to cal back Monday and get price first. Client is aware office is gunna reach out and give her the price. System is in operational upon departure due to bad aria bow speed blower motor. Hollie would cover cost of today’s visit. System is not operational upon departure.
Wildomar, CA 92595
Daniel T.
Daniel T. Checked in
Performed AC maintenance on a Trane condenser. Systems temperature cooling split is 26 degrees. Condensate lines do not have a safety switch but is clear at this time. Indoor blower is amping in range. System is equipped with a AIr scrubber device which is in need of a new catalyst. Filter is dirty but replaced today. Outdoor unit was chemically cleaned and a UV resistant wax was applied. Battery cap is out of range. Starter is ok. Compressor and fan amps are in range at this time. Refrigerant levels are ok. System was
Wildomar, CA 92595
Jimmy P.
Jimmy P. Checked in
Need to return and install two sediment traps on Both heaters
Wildomar, CA 92595
Daniel T.
Daniel T. Checked in
Performed AC maintenance on an Arcoaire Condenser. Systems cooling temperature split is 21 degrees. Upon arrival the condensate was clogged right at the P trap and was able to be easily cleared. Filter was changed. Outdoor coils were chemically cleaned. Fan motor is heavily leaking oil, it is also over amping. The starter has burn marks on the high voltage side and is heavily pitted. The battery cap is out of range on the compressor terminals which is decreasing the life of the compressor. Refrigerant levels look ok. System was cycled before leaving.
Wildomar, CA 92595
Jimmy P.
Jimmy P. Checked in
Performed AC diagnostic on 2014 Aireflo Condenser. Upon my diagnostic client stated that system has been charged approximately three times in the past by a home warranty company. I began my diagnostic at the outdoor condensing unit and found that the system is operational although extremely low on refrigerant charge due to a leak within the refrigeration cycle. 4 ton condenser- 1. System was low approximately 5 pounds of R410a refrigerant 2. Leaked Dye/sealant was injected into the system To help locate and pinpoint location of leak and potentially seal with this kit. 3. Need to return in approximately one month to do leak dye search Charged system up and got a 10° sub cool with a 18° split inside. Client is aware of how system is running at the moment and will be waiting for us to return for a leak dye search. Once the leak is found repair options will be represented and client will decide whether or not he would like to replace or repair at this time of the appointment. Upon depa
Wildomar, CA 92595
Jimmy P.
Jimmy P. Checked in
Need to return and install sediment traps
Wildomar, CA 92595
Darren F.
Darren F. Checked in
Quality control check
Wildomar, CA 92595
Request Service
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon

Call For Same Day Service/Emergencies at 951-234-0748 .

By pressing Submit I agree to receive phone, email, or text messages from Cool Air Solutions Heating & Cooling to the provided mobile number and also agree to the Cool Air Solutions Heating & Cooling terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next