Full-Service HVAC and Plumbing in Menifee Backed by Real Guarantees
When your home needs heating, cooling, or plumbing help, Cool Air Solutions delivers dependable service with no shortcuts and no surprises. From AC tune-ups and new furnace installations to water heater repairs and leak detection, we provide expert care for every comfort system in your home. Homeowners in Menifee count on us for fast, clean, and honest service, always backed by our unbeatable guarantees.
Need service now? Reach out online or call 951-234-0748 to schedule HVAC or plumbing in Menifee today.
Heating and Cooling Experts in Menifee
We handle all things HVAC with precision and care. Whether you're upgrading to a new energy-efficient AC or your furnace isn’t keeping up, our licensed technicians bring the right tools, the right attitude, and rock-solid craftsmanship to every visit.
- AC installation, repair, and maintenance
- High-efficiency furnace and electric furnace installation
- Ductless mini-splits and zoning systems
- Smart thermostat upgrades
- Seasonal system checkups
- Air balancing and airflow improvements
Every installation comes with our full lineup of guarantees—including our Lifetime Craftsmanship Guarantee, 1-Year Test Drive, No Lemon Guarantee, and No Surprise Pricing. And if your system breaks down unexpectedly, you’re covered by our 24-Hour Fix-It Guarantee—or we pay for your hotel stay.
Licensed Plumber in Menifee, CA
Got a leak, clog, or outdated water heater? Our expert plumbing team is ready to help. We specialize in clean, efficient repairs and system replacements that restore your water flow and peace of mind.
- Water heater repair and replacement (standard and tankless)
- Slab leak detection and pipe repair
- Faucet, shower, and toilet service
- Water softeners and filtration systems
- Pressure regulators and backflow prevention
- Garbage disposals, valves, and fixtures
- Camera inspections and sewer cleaning
Our plumbers show up on time, respect your home, and deliver top-tier results backed by our Lifetime Craftsmanship Guarantee—no cut corners, no compromises.
Affordable Options with Five-Star Results
Cool Air Solutions has earned more than 8,000 five-star reviews by putting homeowners first. We offer honest pricing, flexible financing, and a Comfort Club membership to keep your systems running strong year-round.
- Flat-rate pricing with no hidden fees
- Multiple financing options are available
- Exclusive rebates and energy incentives
- Maintenance plans for better performance and fewer breakdowns
- Licensed, insured, background-checked technicians
From energy-efficient upgrades to emergency repairs, you can count on us to get the job done right—and stand behind it.
Schedule Service in Menifee Today
Experience better comfort, better service, and unbeatable protection on every HVAC and plumbing job in Menifee. Use our online form or call 951-234-0748 to book your appointment now—we’ll be there when you need us.
Recent Jobs and Reviews in Menifee, CA
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and trust. Customers consistently praise the company for delivering professional, knowledgeable, and efficient service. A recurring theme is the technical expertise and personable nature of the technicians, who are described as respectful, friendly, and genuinely passionate about their work. Many reviewers highlight the quality of major installations, including complete HVAC system replacements and ductwork, noting impressive speed and precision even under challenging conditions. The company earns strong appreciation for their transparency, thorough documentation, and clear communication about necessary services versus optional ones. Long-term customer loyalty is evident, with clients expressing continued satisfaction over multiple years and repeated service calls. The responsiveness to inquiries and commitment to standing behind their work further reinforces the positive reputation. Overall, the tone is enthusiastic and grateful, with customers feeling valued and confident in the quality and reliability of the service provided.
Menifee, CA at a glance
Cool Air Solutions has completed 25 jobs in Menifee, CA between May 2022 and June 2022.
The most recent job was on June 8, 2022.
Cool Air Solutions has completed 17 jobs in Menifee, CA in the last 12 months. The first job there was in November 2016.
Our Local Reviews by City
- Aguanga, CA (5)
- Aliso Viejo, CA (1)
- Anaheim, CA (5)
- Banning, CA (2)
- Beaumont, CA (5)
- Bonsall, CA (9)
- Buena Park, CA (2)
- Canyon Lake, CA (27)
- Carlsbad, CA (59)
- Carson, CA (1)
- Cathedral City, CA (1)
- Chino, CA (2)
- Chino Hills, CA (4)
- Chula Vista, CA (13)
- Corona, CA (51)
- Del Mar, CA (3)
- Downey, CA (1)
- Eastvale, CA (1)
- El Cajon, CA (8)
- Encinitas, CA (5)
- Escondido, CA (119)
- Fallbrook, CA (65)
- Fontana, CA (2)
- Fountain Valley, CA (2)
- Fullerton, CA (2)
- Garden Grove, CA (5)
- Hacienda Heights, CA (1)
- Hemet, CA (73)
- Homeland, CA (9)
- Huntington Beach, CA (1)
- Irvine, CA (4)
- Jurupa Valley, CA (2)
- La Verne, CA (1)
- Ladera Ranch, CA (1)
- Laguna Hills, CA (5)
- Laguna Niguel, CA (2)
- Laguna Woods, CA (1)
- Lake Elsinore, CA (119)
- Lake Forest, CA (16)
- Lakeside, CA (5)
- Lakewood, CA (1)
- Lemon Grove, CA (1)
- Los Alamitos, CA (1)
- Menifee, CA (203)
- Mission Viejo, CA (8)
- Moreno Valley, CA (26)
- Murrieta, CA (670)
- Newport Beach, CA (1)
- Norco, CA (3)
- Nuevo, CA (2)
- Oceanside, CA (86)
- Ontario, CA (1)
- Pala, CA (1)
- Pauma Valley, CA (7)
- Perris, CA (24)
- Poway, CA (9)
- Ramona, CA (4)
- Rancho Cucamonga, CA (1)
- Rancho Santa Fe, CA (2)
- Rancho Santa Margarita, CA (2)
- Redlands, CA (4)
- Riverside, CA (36)
- San Bernardino, CA (4)
- San Clemente, CA (1)
- San Diego, CA (81)
- San Dimas, CA (1)
- San Jacinto, CA (28)
- San Juan Capistrano, CA (2)
- San Marcos, CA (48)
- Santa Ana, CA (3)
- Santa Fe Springs, CA (1)
- Solana Beach, CA (1)
- Spring Valley, CA (5)
- Sun City, CA (1)
- Temecula, CA (762)
- Temescal Valley, CA (1)
- Trabuco Canyon, CA (3)
- Upland, CA (2)
- Valley Center, CA (18)
- Vista, CA (161)
- Warner Springs, CA (5)
- Wildomar, CA (77)
- Winchester, CA (125)
- Yorba Linda, CA (14)
- Yucaipa, CA (5)
Job Locations and Reviews
Performed AC maintenance. Inspected and tightened electrical components. Checked filter and changed- customer provided . Inspected ducting to ensure proper airflow. Temperature split was at 20degrees.inspected and cleared condensate lines, system had flood protection drain pan and float switch. Checked outdoor electrical components, measured capacitor- it is within range. Checked contactor and hard start kit. Washed and cleaned outdoor condenser coils. Removed debris from bottom of the condenser and cleaned and removed debris from electrical cabinet. System is cooling and operational upon departure. Customer asked that I check far right attic fan as it was rattling I did inform her we don’t work on these fans but did inspect bolts to ensure it was secure and took photos of fan motor as it was caked with debris for her to see if there is some type of service that she can have done from the company who installed the unit as it could be possible the debris on the motor is causing it t
Arrived on site to perform diagnostic on 12 year old York system. Homeowner states system is not cooling. Indoor motor is not turning on. He has replaced 2 circuit boards, both of which get burnt out immediately after he installed them. Has also replaced a transformer and capacitor. Inspected indoor unit electrical and components. Circuit board on unit is obviously fried. All 3 board have burnt fan relay. Checked indoor motor and it is completely seized up. Indoor motor needs to be replaced before new circuit board is put on. Can not verify that there is nothing else wrong with unit until parts are replaced. Went over options and pricing. Homeowner states he will be ordering parts himself and repairing. System is not operational upon departure.
Performed AC maintenance. Inspected and tightened electrical components. Checked and changed filter. Inspected ducting to ensure proper airflow. Temperature split was at 20degrees.inspected and cleared condensate lines, system ha flood protection drain pan and float switch. Repaired condensate line that had become un attached and used PVC cement. Checked outdoor electrical components, Washed and cleaned outdoor condenser coils. Removed debris from bottom of the condenser and cleaned and removed debris from electrical cabinet. System is cooling and operational upon departure
16 SEER Lennox A/C & Heat 6.99% 120 month - $141 CLIENT IS PUTTING $1000 DEPOSIT TO HOLD EQUIPMENT FOR 45 DAYS AND TO INSTALL, REVOKING RIGHT TO CANCEL
Arrived on site to install new blower motor. Installed and cycled unit and is operational. Client did declined any to add surge protectors inside and out side a a bundle price. I talked both surge protectors and both are good. Unit is operational upon departure. Client already paid for repairs done today no amount collected.
Upon arrival, condenser was operational but not cooling. Hooked up gauges and found system to be low on charge. Went through entire system. Outdoor unit electrical was in bad shape. No ground wire is installed currently leaving the system vulnerable to surges. High voltage to the unit is exposed. Made recommendations to client. Because of high repair bills and the R22 refrigerant situation, client would like to look at replacement vs repair options.
Upon arrival started tune up of 5 year old condenser. Cleaned condenser coil and checked electrical. Condenser fan motor is showing signs of over heating. Motor amps revealed its close to max amps. Charge and temp split are good. Static pressure is high in system. System ducts are undersized. Made recommendations to client. Unit is operational upon departure.
Upon arrival, client said water was in the supply ducting. System is a downflow. Checked evaporator coil. The pan is dirty and so is the coil. Water and dirt has been filling the pan creating a sludge that clogged the drains. Attempted to clear out the drain as best I could with the limited access. However there is still stuff in the pan. Need to pull out the evaporator coil and clean both the pan and coil. Once clean and installed the ducts will need to be cleaned to prevent any growth. System is 33 years old. Still operational. Outdoor condenser is in poor condition. Electrical is old and should be replaced. Condenser fan motor was not properly secured. Unit is still operational. Advise not running unit until repairs can be made to prevent more water getting into the pan.
Arrived on site to return for repairs on a blower motor. Was replacing but found unit would not work. Advised client and they would like to just order a oem one. Ordered new motor and will be calling them tomorrow once we get it.
Price can be reduced by $850 if this can be installed Tuesday or Wednesday due to a job reschedule
Arrived on site to perform diagnostic on 3 year old system. Homeowner states that system is not cooling the home like it used to. Has been ongoing for about a week. Cycled system for cooling. Checked outdoor unit and found that compressor is not cycling on, which is causing unit not to cool. After inspecting electrical components found that secondary motor control for compressor is completely dead. Put in new secondary motor control temporarily and cycled system. System came on and started cooling. Verified proper refrigerant pressures. Performed thorough evaluation of system and found a couple concerns, which are as follows: 1. System is a single stage unit on 2 zone system. This causes extreme pressure on system when 1 out of the 2 zones is shut off as unit is producing same amount of airflow with only 1/2 of the supply open. 2. Unit was relocated and additional line set was added. This also causes slight additional wear and tear on the equipment. 3. A fence was built around the out
Technician performed spring tune up -Condenser was throughly cleaned out for efficiency and longevity of the system -All electrical components are working properly and within range -Refrigerant levels were within range -Condensation lines were cleared with nitrogen -A phenomenal air was recommended to combat the clients allergy problem -Clients system is working great and ready for summer
Performed maintenance on 2 2018 Carrier units. Cycled systems for cooling. Checked indoor and outdoor units electrical and system components. Temperature splits in range. Filters are due for replacement, homeowner replaces them and will take care of it. Checked outdoor unit electrical and system components. Ran systems through 20 point inspection. Pulled condenser motors and thoroughly washed out condenser coils inside and out. Would definitely recommend continuing to get them cleaned yearly as they do get really dirty. Outdoor disconnects are not surge protected, as well as indoor condensation drain lines do not have any safety switches in place in the event of a draining issue. Emailing recommendations over. Cycled system, system is operational upon departure.
Upon arrival found upstairs condenser fan motor running backwards. Further inspection found the motor controller had failed. Most likely from airflow issues. Condenser fan motor was also failing but operational. Brought up issues for client. They moved forward with the recommend repairs. Installed motor and motor controller. Tested unit. Is now operational. Client moved forward with comfort club.
Upon arrival found compressor wire to be completely burnt off. Was causing system to kick on & off. Replaced wire got compressor going but it running at max amps. Client is looking for options to replace.
Upon arrival found compressor wire to be completely burnt off. Was causing system to kick on & off. Replaced wire got compressor going but it running at max amps. Client is looking for options to replace.
Upon arrival found compressor wire to be completely burnt off. Was causing system to kick on & off. Replaced wire got compressor going but it running at max amps. Client is looking for options to replace.
Upon arrival found compressor wire to be completely burnt off. Was causing system to kick on & off. Replaced wire got compressor going but it running at max amps. Client is looking for options to replace.
Arrived on site to perform diagnostic on a 2010 lennox unit or cooling home and making loud noise. Spoke to client and stated unit is not cooling home. Cycled unit and was not operational. She stated it was working in past just recently it stoped. Inspected electrical compartment indoor and put side. Found secondary motor control bad and replaced and un was operational. Got unit to turn on and produce cold air. Advised I would inspect full system to prevent any future issue. Found hole to be zoned on a single stage furnace. Advised motor is just singlet stage and is gunna over working when just one zones it on. Recommend upgrading motor to a ecm motor to help prolong unit and not work as hard. Wheel is dirty and found no protection on zoned unit. Inspected condenser. Primary starter is pitting on contact points still running but would recommend replacing due to condition. Fan motor okay just working hard as cons has not been cleaned or maintenance in years. Recommend join to get unit c
Arrived on site to perform invoice tune up on a 1 year old unit. Client stated no issues and good as it’s new. Cycled heating and cooling and was operational. Filter was replaced by client. Motor and blower assembly is good. Unit is heating at 38 degrees. All safety switches are operational. Drain lines are good. Found no protection for n furnace and recommended adding surge protectors on system. Cycled cooling and washed condenser coil inside and out. Checked electrical compartment and components. Primary and secondary motor controls are good. Fan motor is good. Checked start up and run amps and both are good and in range. Checked pressure and u it is holding good charge and cooling home at 19 degrees. Advised no protection on either unit and highly advised unit should have protection equipped to ensure no issues happen and prolong life of unit. Wife stated she would talk over with husband and he would go over report. Client did hold off for now. But did sign up for ESA yearly. Cyc
Technician performed Spring Tune-Up for client -Condenser was thoroughly cleaned with water for efficiency and longevity of the system -Refrigerant levels were within range -Electrical components were pulling within proper range expect the Fan motor -The Fan motor was pulling 1/1 amps which is high -Fan motor was also leaking oil which is a sign that the motor is on its way out -Filters were changed -The blower motor housing was very dirty resulting in the motor having to work harder to produce air -Recommendations for today to increase longevity of the system would be to: Replace Fan Motor and conduct a blower motor cleaning -Other than that the system is doing its job and cooling
Upon arrival, found a 4 year old package unit. Cleaned condenser coils. Checked electrical. Found no issues. Airflow is good. Replaced filter. Checked charge and temp split. Systems are good. Installed surge protector. Tested system. Unit is operational upon departure.
Performed cooling tune up on Lennox system. Checked filter and blower amp draws, cleared primary condensate trap with vacuum and primed wit water. Measured temp split. Measured refrigerant charge and tested electrical. Cleaned condenser and washed coils.
Arrived on site to perform diagnostic on system. Homeowner states unit is not cooling, and in the summer time the unit runs all day long but never cools the house down. Cycled system for cooling. Unit kicked on normally. Performed full diagnosis and evaluation on system. Concerns are as follows: 1. Unit is operating on low charge of refrigerant. System has had to be charged up with refrigerant before. Explained that refrigerant should never leave a system unless it develops a leak, in which case refrigerant well keep leaking until leak is repaired. 2. Found refrigerant leak on outdoor condenser coil. Because of leak being in condenser coil, it is not repairable unless coil is replaced. 3. Unit operated on r-22 refrigerant, which has been phased out and no longer being produced and is extremely expensive. 4. Condenser fan motor is leaking significant amount of oil and amperage is high. 5. Condenser and evaporator coil are mis matched. Condenser coil is a 5 ton and evap coil is 3.5 to
Performed estimate on whole home air filtration and purification system. Unit is an up flow in laundry room, so options are limited. Ductwork is new and has recently also been cleaned. Went over options with homeowners. They like the idea, but need to hold off as they want to eliminate all the outdoor dust first. They have a contractor coming to check the windows and doors to make sure everything is tightly sealed. Signed up on maintenance program. Waived Diagnostic.