Full-Service HVAC and Plumbing in Menifee Backed by Real Guarantees
When your home needs heating, cooling, or plumbing help, Cool Air Solutions delivers dependable service with no shortcuts and no surprises. From AC tune-ups and new furnace installations to water heater repairs and leak detection, we provide expert care for every comfort system in your home. Homeowners in Menifee count on us for fast, clean, and honest service, always backed by our unbeatable guarantees.
Need service now? Reach out online or call 951-234-0748 to schedule HVAC or plumbing in Menifee today.
Heating and Cooling Experts in Menifee
We handle all things HVAC with precision and care. Whether you're upgrading to a new energy-efficient AC or your furnace isn’t keeping up, our licensed technicians bring the right tools, the right attitude, and rock-solid craftsmanship to every visit.
- AC installation, repair, and maintenance
- High-efficiency furnace and electric furnace installation
- Ductless mini-splits and zoning systems
- Smart thermostat upgrades
- Seasonal system checkups
- Air balancing and airflow improvements
Every installation comes with our full lineup of guarantees—including our Lifetime Craftsmanship Guarantee, 1-Year Test Drive, No Lemon Guarantee, and No Surprise Pricing. And if your system breaks down unexpectedly, you’re covered by our 24-Hour Fix-It Guarantee—or we pay for your hotel stay.
Licensed Plumber in Menifee, CA
Got a leak, clog, or outdated water heater? Our expert plumbing team is ready to help. We specialize in clean, efficient repairs and system replacements that restore your water flow and peace of mind.
- Water heater repair and replacement (standard and tankless)
- Slab leak detection and pipe repair
- Faucet, shower, and toilet service
- Water softeners and filtration systems
- Pressure regulators and backflow prevention
- Garbage disposals, valves, and fixtures
- Camera inspections and sewer cleaning
Our plumbers show up on time, respect your home, and deliver top-tier results backed by our Lifetime Craftsmanship Guarantee—no cut corners, no compromises.
Affordable Options with Five-Star Results
Cool Air Solutions has earned more than 8,000 five-star reviews by putting homeowners first. We offer honest pricing, flexible financing, and a Comfort Club membership to keep your systems running strong year-round.
- Flat-rate pricing with no hidden fees
- Multiple financing options are available
- Exclusive rebates and energy incentives
- Maintenance plans for better performance and fewer breakdowns
- Licensed, insured, background-checked technicians
From energy-efficient upgrades to emergency repairs, you can count on us to get the job done right—and stand behind it.
Schedule Service in Menifee Today
Experience better comfort, better service, and unbeatable protection on every HVAC and plumbing job in Menifee. Use our online form or call 951-234-0748 to book your appointment now—we’ll be there when you need us.
Recent Jobs and Reviews in Menifee, CA
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and trust. Customers consistently praise the company for delivering professional, knowledgeable, and efficient service. A recurring theme is the technical expertise and personable nature of the technicians, who are described as respectful, friendly, and genuinely passionate about their work. Many reviewers highlight the quality of major installations, including complete HVAC system replacements and ductwork, noting impressive speed and precision even under challenging conditions. The company earns strong appreciation for their transparency, thorough documentation, and clear communication about necessary services versus optional ones. Long-term customer loyalty is evident, with clients expressing continued satisfaction over multiple years and repeated service calls. The responsiveness to inquiries and commitment to standing behind their work further reinforces the positive reputation. Overall, the tone is enthusiastic and grateful, with customers feeling valued and confident in the quality and reliability of the service provided.
Menifee, CA at a glance
Cool Air Solutions has completed 25 jobs in Menifee, CA between December 2022 and January 2023.
The most recent job was on January 18, 2023.
Cool Air Solutions has completed 18 jobs in Menifee, CA in the last 12 months. The first job there was in November 2016.
Our Local Reviews by City
- Aguanga, CA (5)
- Aliso Viejo, CA (1)
- Anaheim, CA (5)
- Banning, CA (2)
- Beaumont, CA (5)
- Bonsall, CA (9)
- Buena Park, CA (2)
- Canyon Lake, CA (27)
- Carlsbad, CA (59)
- Carson, CA (1)
- Cathedral City, CA (1)
- Chino, CA (2)
- Chino Hills, CA (4)
- Chula Vista, CA (13)
- Corona, CA (51)
- Del Mar, CA (3)
- Downey, CA (1)
- Eastvale, CA (1)
- El Cajon, CA (8)
- Encinitas, CA (5)
- Escondido, CA (119)
- Fallbrook, CA (65)
- Fontana, CA (2)
- Fountain Valley, CA (2)
- Fullerton, CA (2)
- Garden Grove, CA (5)
- Hacienda Heights, CA (1)
- Hemet, CA (73)
- Homeland, CA (9)
- Huntington Beach, CA (1)
- Irvine, CA (4)
- Jurupa Valley, CA (2)
- La Verne, CA (1)
- Ladera Ranch, CA (1)
- Laguna Hills, CA (5)
- Laguna Niguel, CA (2)
- Laguna Woods, CA (1)
- Lake Elsinore, CA (119)
- Lake Forest, CA (16)
- Lakeside, CA (5)
- Lakewood, CA (1)
- Lemon Grove, CA (1)
- Los Alamitos, CA (1)
- Menifee, CA (203)
- Mission Viejo, CA (8)
- Moreno Valley, CA (26)
- Murrieta, CA (670)
- Newport Beach, CA (1)
- Norco, CA (3)
- Nuevo, CA (2)
- Oceanside, CA (86)
- Ontario, CA (1)
- Pala, CA (1)
- Pauma Valley, CA (7)
- Perris, CA (24)
- Poway, CA (9)
- Ramona, CA (4)
- Rancho Cucamonga, CA (1)
- Rancho Santa Fe, CA (2)
- Rancho Santa Margarita, CA (2)
- Redlands, CA (4)
- Riverside, CA (36)
- San Bernardino, CA (4)
- San Clemente, CA (1)
- San Diego, CA (81)
- San Dimas, CA (1)
- San Jacinto, CA (28)
- San Juan Capistrano, CA (2)
- San Marcos, CA (48)
- Santa Ana, CA (3)
- Santa Fe Springs, CA (1)
- Solana Beach, CA (1)
- Spring Valley, CA (5)
- Sun City, CA (1)
- Temecula, CA (762)
- Temescal Valley, CA (1)
- Trabuco Canyon, CA (3)
- Upland, CA (2)
- Valley Center, CA (18)
- Vista, CA (161)
- Warner Springs, CA (5)
- Wildomar, CA (77)
- Winchester, CA (125)
- Yorba Linda, CA (14)
- Yucaipa, CA (5)
Job Locations and Reviews
Arrived on site to perform heating tune up on unit. Client stated no issues and is working good but did have a question at time of how unit is running he hears a noise. Cycled unit and didn’t hear any noise while running. Found new flex ducting. Blower assembly and wheel is good and clean. Filter are dirty but client has them and replace. Evaporator coil is good and clean. Drain lines are good. No safety over flow switch. Recommend adding to prevent over flow. Temperature rise is good at this time and heating home good and in range. Found unit was really old out side and was going into defrost mode. Showed him that is the noise he was hearing. He is aware it’s normal. No protection added on unit and recommended adding to protect systems from electrical surges and power outages. Cycled unit and went over findings with unit. He is aware how unit is running and conditions. Client did hold off on recommendations.
Arrived on site to preform furnace maintenance on 2019 amana systems.
Arrived on site to diagnose a no heating 1988 unit. Unit is original to home. Client just moved in 2 days ago and had there home inspect and just yesterday alarms went off and they had a gas company out and stated there heater had been by passed on the door switch. Stated it needed to get fixed for safety reasons. Call us out. Inspect unit and unit is in very bad condition. Found a lot of wires cut and wire nutted inspect of completed wires. Advised past people were doing stuff and cutting alot of corners. Tested door switch that was bypassed and it was operational. Wires it to to the switch and cycle and unit started working. Went through full system found it to be very old and motor is leaking. Found burners flames shooting a flame to the side and showed client and stated that is a huge safety concern as it can risk of catching on fire due to how it’s shooting the flame. Found supply side to be leaking a lot of air behind unit. Unit only has one drain line and is not up to current
Arrived on site to install components. Circuitboard and pressure switch for installed that are fully operational upon departure
Arrived on site to perform furnace maintenance on 2004 Armstrong heater. Upon arrival Laura stated that system is used throughout the day and not at night. Performed a full Safety inspection and maintenance to heater and found multiple points of concerns. 1. Measured temperature rise and found that it had a total of 83° indicating that furnace is overheating severely. 2. Indoor blower motor has oil leakage 3. Return intakes are significantly undersized 4. Airflow is heavily restricted in reading a total of 0.90 static pressure 5. Gas line is not up to code 6. Condensation pipes are not properly glued together and missing water sensor switch 7. Heat exchanger has multiple heat spots And oxidization. Although did not find any cracks on heat exchanger it is possible that they are not visible at this time. Discussed full maintenance with client and she is aware of all possible Failure points within the unit. Clients plan on living in the home forever and would like to get replacement opti
Performed a hearing maintenance on a ac pro system. Cleaned and Adjust Burners. Check Combustion Air for Proper Venting. Examine the Heat Exchanger for Damage / Corrosion. Test Furnace Safety Controls. Inspect Gas Piping. Tighten Electrical Connections. Measure the Voltage and Amperage. Flush the Condensate Drains. Measure Tempurature Difference between Supply and Return Air. Vacuum Furnace Return Grille. Adjust Gas Pressure & Pilot. Clean in-place Blower Compartment. Inspect Blower Wheel for Proper Balance. Check the System's Static Pressures to Ensure Proper Airflow. Inspect Duct Connections for Air Leaks / Sizing / Insulation. Check all System Safety and Limit Switches. Clean Flame Sensor. Inspect Carbon Monoxide Detector. Check Thermostat for Proper Operation / Calibration. Filters where not changed this visit. System was fully operational on time of departure. Explained to customer they need to move there cabinets from in front of the return because it can cause damage to the syst
Installed velcro insulation wrap to the outdoor lineset
Arrived on site to perform furnace diagnostic on 2008 Goodman. Upon arrival homeowner stated that system shut off soon after I left. Proceeded to indoor unit and found pressure switch stuck open in circuitboard indicating three flashes. Jumped pressure switch out in system still did not turn on indicating that the circuitboard and pressure switch both failed. Will be ordering new component in arriving once part is in hand upon departure unit is non-operational
Arrived on site to preform furnace diagnostic on 2008 Goodman heater m. Client states previous company was out to fix cap on motor and now he’s is not answering. Began diagnostic and found system is operational. Tested unit 10 times and furnace did not replicate issue that was happening yesterday. Flame sensor is clean and igniters is okay. Temp rise is in range. Client signed up on maintenance to keep system at standard. Upon departure Unit is fully operational in heating mode.
Arrived on site to preform a 20 point furnace Maintenance. Checked filter, filter was dirty swapped it out customer has a custom contract which incudes merv 16 filter with maintenance membership every visit 16X25X5. Went over and recorded the 20 point inspection. Everything was operational and functional, nothing of concern to note talked to customer about surge protection on unit. Unit was operational upon departure.
Performed heating maintenance on system. Cycled system for heating. Verified proper heating sequence of operations. Ran system through 20 point inspection checklist. Temperature rise across heat exchanger is within range. Replaced filter. System is of older age and has some concerns. 1. Gas line is not hard piped out of the furnace, and does not have a sediment trap. 2. Condensation lines do not have any condensation switches. 3. Blower wheel is very dirty. 4. Inducer draft motor is starting to over amp. 5. Indoor blower motor is leaking oil, and amp draws are high. 6. ductwork is designed very poorly. Cycled system, system is operational upon departure.
During my twenty point heating inspection, I started with the thermostat. Giving a call for heating, and going to furnace to start maintenance. I checked out blower motor of any dirt or debris and it’s dirty. Replaced air filter for a new one. Hot surface igniter not cracked or having white spots. Flame sensor still working good, and deep cleaned. Ducting done correctly, and all runs intact. Inducer motor is working at high amps along with furnace too. Moved onto the upstairs unit, I shut off downstairs after I was done with my inspection. Put system in a call for heating mode. Soon as the house warmed up after thirty minutes. I checked out blower motor of any dirt or debris. It’s clean, well maintained system. Existing air filter was very dirty, and I replaced air filter. No gas leaks in system, everything pipe doped. Hot surface igniter not cracked or having white spots. Flame sensor still working good, but cleaned. Ducting done correctly, and all runs intact. Inducer motor is w
Performed heating maintenance on 8 year old Lennox unit.<br> <br> Cleaned return grate. Replaced filter with owner-supplied 3M filter. I let James know that he can fit a 2†filter in his filter cabinet that will last longer and allow more air flow for his system. Checked all safety switches. Cleaned flame sensor. Tested pressure switch. Checked external static pressure and found it to be high, this is most likely due to it being in an upflow position. Flushed condensate drain with water. Temperature rise is within limits. Inducer amp draw as well as total system amp draw are within limits. Ductwork appears to be in good condition and was replaced about 6 years ago. Inspected blower compartment and found blower wheel to be balanced but dusty, this should be cleaned within the next year.<br> <br> While talking to James about his system I brought it to his attention that there are no surge protective devices installed on his furnace. He will consider having one installed for
Performed a heating maintenance on a 2019 carrier system. Filters where not changed this visit. Test Furnace Safety Controls. Tighten Electrical Connections. Measure the Voltage and Amperage. Flush the Condensate Drains. Measure Tempurature Difference between Supply and Return Air. Vacuum Furnace Return Grille. Clean in-place Blower Compartment. Inspect Blower Wheel for Proper Balance. Check the System's Static Pressures to Ensure Proper Airflow. Inspect Duct Connections for Air Leaks / Sizing / Insulation. Check all System Safety and Limit Switches. Clean Flame Sensor. Inspect Carbon Monoxide Detector. Check Thermostat for Proper Operation / Calibration. System was fully operational on time of departure.
Performed heating maintenance on 2 year old Lennox Elite condensing furnace.<br> <br> Replaced filter with new owner-supplied filter. Cleaned return grate. Temperature rise is within limits. Checked all electrical connections. Tested safety switches and pressure switch. Inspected gas line. Inspected combustion exhaust. I believe the attic is sealed, but I noticed that the furnace is pulling air for combustion from the attic. If it is sealed this needs to be remedied by installing an intake for combustion air that pulls from outside of the home to prevent decreasing the pressure in the attic. Inspected blower wheel and found it to be clean and balanced. I mentioned to Nick a MERV filter would improve air quality in their home and keep the air inside of their HVAC system a lot cleaner. There is plenty of room for a MERV cabinet to be installed between the return plenum and their furnace. Upon departure the system is operational.
Upon arrival client had a main limit control tripped. System is operational, client changed filter out on the 12th of dec. System is a 3 ton system with only 5 vents. That is not enough airflow to pass through that system, system can be over heating due to very low airflow demand. Advised we may need to do about 9 cut into to leave air in perfect demand for a 3 ton system. Drew something quick out for client. Needs to take care of some debt before moving forward, maybe February. Has been changing filters regularly though. System is operational as of now .
Upon arrival client had a main limit control tripped. System is operational, client changed filter out on the 12th of dec. System is a 3 ton system with only 5 vents. That is not enough airflow to pass through that system, system can be over heating due to very low airflow demand. Advised we may need to do about 9 cut into to leave air in perfect demand for a 3 ton system. Drew something quick out for client. Needs to take care of some debt before moving forward, maybe February. Has been changing filters regularly though. System is operational as of now .
Upon arrival client had a main limit control tripped. System is operational, client changed filter out on the 12th of dec. System is a 3 ton system with only 5 vents. That is not enough airflow to pass through that system, system can be over heating due to very low airflow demand. Advised we may need to do about 9 cut into to leave air in perfect demand for a 3 ton system. Drew something quick out for client. Needs to take care of some debt before moving forward, maybe February. Has been changing filters regularly though. System is operational as of now .
Upon arrival client had a main limit control tripped. System is operational, client changed filter out on the 12th of dec. System is a 3 ton system with only 5 vents. That is not enough airflow to pass through that system, system can be over heating due to very low airflow demand. Advised we may need to do about 9 cut into to leave air in perfect demand for a 3 ton system. Drew something quick out for client. Needs to take care of some debt before moving forward, maybe February. Has been changing filters regularly though. System is operational as of now .
Performed diagnostic. Unit is not operating. Thermostat says it cannot communicate with equipment. Checked wiring between hub and thermostat. Smart hub is powering up but not communicating. Replaced with new smart hub. Configured settings. Unit is communicating once again. Cycled system through modes. System is fully operational.
Follow up to replace 4 filter.
Arrived on site to perform heating tune up on 2 6 year old carriers. Client stated no issues as they are young. Filter he is going to replace himself as he is buying them. Both units operating. Found black flex ducting used for both units. Both Blower assembly are good slight dusty advised to be replacing filter every 3 months. Motor are both good. Circuit board are good and connections. Inducer motor is in range on both. Both igniter are good. Both flame sensor are in range. Temperature rise is good on both. All safety switches are operational. Drain lines are clear at this time but have no safety over flow switches. Cycled heater and found no protection added on and recommend adding some to protect unit from electrical surges and power outages. Due to clients likening clean are quality and recommended adding phenomenal airs to units to help clean and purify the air in whole house instead of just one room. Cycled both units and went over how units are running and there conditions. Cli
Arrived on site to diagnose a no heating unit. Client stated unit is really old and looks to be original to home home is from 1964. Upon. Arrival found that client has done repairs to unit himself. Vm but he would cycle and would hear it click and nothing would happen. Inspected electrical compartment. Found no board just relays and parts. Tested for power and found no low voltage going to unit or thermostat. Traced back and found that transformer was not working. Unit was getting 120 but also found that the pig tale wire was cut and wire were exposed and moved wires and found exposed wires. Advised possible short may have happened and possibly made transformer fail. Advised client of minimum findings and repairs needed. Client stated he was just trying to repair unit as his plan is to sell home next year. Gave him pricing for minimum repairs needed but advised there could be more issues but won’t know until parts are swapped. Client is aware but did declined repairs for today. He i
Arrived on site to perform heating tune up on a 2 arcoair package units. Client stated no issues and has been using heaters. Cycled both on and operational. Filter were washed and replaced by client. Advised them to be doing it every 3 months at most. Inspect main home unit first. Found inducer motor over amping and leaking oil. Recommended replacing. Found Knox rods in burners deteriorating due to over heating. Flame sensor is oxidizing from use and age. Blower day and wheel is dusty from age and dirt going in. Motor amps are in range just high. Inspected heat exchanger and found them Olay at this time just have big hot spots from over heating in pst years as they do use heater more. No protection. Guest home unit. Inducer motor was in range. Blower assembly is dusty. Motor is good. Inducer motor is in range. Flame sensor is worn out from use. Temperature rise is good. Drain lines are good. All safety switches are operational went over all findings with client and he is aware units ar
Upon arrival performed maintenance on Ducane system. Circuit board and electricals look good. Indoor motor is leaking a lot of oil. Blower wheel extremely dirty. Inducer draft motor is over amping. Found crack in the head exchanger. Verified with Darren. Client did not wanna pull heat exchanger for a full check. Shut the gas off. Advised why it’s not safe to run when metal is salvaged. Is not looking to replace right now wants to go compellty break down . System is operational but shut gas off.