Trusted HVAC, Plumbing & IAQ Services in Lake Elsinore—Backed by Unbeatable Guarantees
In a place like Lake Elsinore, where summer temperatures soar and water quality challenges are common, having reliable HVAC and plumbing systems is non-negotiable. At Cool Air Solutions, we provide expert heating, cooling, plumbing, and indoor air quality services designed to protect your comfort, your home, and your budget. Our licensed professionals deliver clean, efficient solutions—all backed by the strongest guarantees in the business.
Need service today? Reach out through our online request page or call 951-234-0748 to book HVAC, plumbing, or IAQ service in Lake Elsinore.
Heating and Air Conditioning in Lake Elsinore
The climate in Lake Elsinore demands reliable cooling in the summer and safe, efficient heating during the cooler months. Our certified HVAC team is here to help you maintain ideal indoor comfort while reducing energy costs and extending system life.
-
AC Repair & Replacement: We repair refrigerant issues, bad compressors, failing fans, and other common problems. Need an upgrade? We’ll install a high-efficiency unit that matches your home and budget.
-
Furnace Installation & Service: We handle safe installation, repairs, and tune-ups for gas and electric furnaces, keeping your home warm and your energy bills under control.
-
Ductless Mini-Splits: These systems are ideal for add-ons, home offices, or multi-zone control and deliver powerful, efficient comfort without ducts.
-
Heat Pumps: Dual-purpose systems that heat and cool efficiently year-round—perfect for Southern California climates.
-
Smart Thermostat Installation: Control your system from your phone, create schedules, and save on utilities with smart thermostat upgrades.
-
HVAC Maintenance Plans: Our seasonal tune-ups help prevent breakdowns, improve airflow, and extend your system’s lifespan.
-
Duct Repair & Airflow Balancing: We diagnose and fix uneven temperatures and noisy ducts by correcting airflow and sealing leaks.
Your installation is protected by our Lifetime Craftsmanship Guarantee, 1-Year Test Drive, No Lemon Guarantee, No Surprise Pricing, and 24-Hour Fix-It Guarantee—we’ll cover your hotel stay if we can’t get your comfort back in a day.
Plumbing Services in Lake Elsinore
Lake Elsinore homes often experience hard water and aging plumbing infrastructure, which can lead to wear and tear over time. Our licensed plumbers offer fast, high-quality solutions that restore performance, improve efficiency, and give you long-term confidence.
-
Water Heater Installation & Repairs: We install and repair both traditional and tankless systems, ensuring your home never runs out of hot water.
-
Slab Leak Detection: Using advanced diagnostic tools, we pinpoint and repair foundation leaks before they cause serious damage.
-
Pipe Repairs & Repiping: Whether it’s a small leak or time to upgrade your piping system, we offer durable solutions with clean workmanship.
-
Toilets, Faucets & Fixtures: We repair or install water-saving fixtures that update your home and cut water waste.
-
Water Softeners & Filtration Systems: Hard water is common in Lake Elsinore—we install systems that improve water quality and protect your plumbing.
-
Sewer Camera Inspections & Drain Cleaning: We find and clear clogs at the source, preventing backups and costly repairs.
-
Garbage Disposal Repairs: Fast, affordable service for jammed, leaking, or outdated disposal units.
-
Backflow & Pressure Regulators: We install devices to protect your water supply and keep your plumbing code-compliant.
All plumbing work is backed by our Lifetime Craftsmanship Guarantee for your complete peace of mind.
Indoor Air Quality (IAQ) Services in Lake Elsinore
From wildfire smoke to dust and allergens, indoor air in Lake Elsinore can quickly become unhealthy. Our IAQ solutions help you breathe easier while improving HVAC performance.
-
Whole-Home Air Purifiers: Remove dust, pollen, bacteria, and VOCs from every room through your HVAC system.
-
High-Efficiency Filters: Extended media filters last longer and trap more airborne contaminants.
-
Humidity Control: Balance dry or damp indoor air with whole-home humidifiers and dehumidifiers.
-
Duct Cleaning & Sealing: Improve indoor air and reduce energy waste with professional duct services.
-
Fresh Air Ventilation Systems: Bring in outdoor air without losing comfort or efficiency.
Why Lake Elsinore Trusts Cool Air Solutions
Thousands of homeowners across Riverside County rely on Cool Air Solutions for comfort that lasts. Here’s what sets us apart:
-
We know local homes. From hard water to high heat, we tailor every solution to your neighborhood’s needs.
-
We work clean. Shoe covers, drop cloths, and spotless cleanup are part of our process, every visit.
-
No-pressure recommendations. We explain your options clearly and let you decide what’s right.
-
Financing options are available. We’ll help you access rebates and flexible payment plans to make upgrades easy.
-
Our guarantees are real. They’re printed, transparent, and honored every time.
Book HVAC, Plumbing, or IAQ Service in Lake Elsinore Today
From fast repairs to energy-saving system upgrades, Cool Air Solutions delivers comfort you can count on—with guarantees you won’t find anywhere else.
Schedule your appointment online or call 951-234-0748 to book your HVAC, plumbing, or air quality service in Lake Elsinore.
Recent Jobs and Reviews in Lake Elsinore, CA
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and trust. Customers consistently praise the company for delivering professional, knowledgeable, and efficient service. A recurring theme is the technical expertise and personable nature of the technicians, who are described as respectful, friendly, and genuinely passionate about their work. Many reviewers highlight the quality of major installations, including complete HVAC system replacements and ductwork, noting impressive speed and precision even under challenging conditions. The company earns strong appreciation for their transparency, thorough documentation, and clear communication about necessary services versus optional ones. Long-term customer loyalty is evident, with clients expressing continued satisfaction over multiple years and repeated service calls. The responsiveness to inquiries and commitment to standing behind their work further reinforces the positive reputation. Overall, the tone is enthusiastic and grateful, with customers feeling valued and confident in the quality and reliability of the service provided.
Lake Elsinore, CA at a glance
Cool Air Solutions has completed 25 jobs in Lake Elsinore, CA in June 2021.
The most recent job was on June 26, 2021.
Cool Air Solutions has completed 12 jobs in Lake Elsinore, CA in the last 12 months. The first job there was in November 2016.
Our Local Reviews by City
- Aguanga, CA (5)
- Aliso Viejo, CA (1)
- Anaheim, CA (5)
- Banning, CA (2)
- Beaumont, CA (5)
- Bonsall, CA (9)
- Buena Park, CA (2)
- Canyon Lake, CA (27)
- Carlsbad, CA (59)
- Carson, CA (1)
- Cathedral City, CA (1)
- Chino, CA (2)
- Chino Hills, CA (4)
- Chula Vista, CA (13)
- Corona, CA (51)
- Del Mar, CA (3)
- Downey, CA (1)
- Eastvale, CA (1)
- El Cajon, CA (8)
- Encinitas, CA (5)
- Escondido, CA (119)
- Fallbrook, CA (65)
- Fontana, CA (2)
- Fountain Valley, CA (2)
- Fullerton, CA (2)
- Garden Grove, CA (5)
- Hacienda Heights, CA (1)
- Hemet, CA (73)
- Homeland, CA (9)
- Huntington Beach, CA (1)
- Irvine, CA (4)
- Jurupa Valley, CA (2)
- La Verne, CA (1)
- Ladera Ranch, CA (1)
- Laguna Hills, CA (5)
- Laguna Niguel, CA (2)
- Laguna Woods, CA (1)
- Lake Elsinore, CA (119)
- Lake Forest, CA (16)
- Lakeside, CA (5)
- Lakewood, CA (1)
- Lemon Grove, CA (1)
- Los Alamitos, CA (1)
- Menifee, CA (203)
- Mission Viejo, CA (8)
- Moreno Valley, CA (26)
- Murrieta, CA (670)
- Newport Beach, CA (1)
- Norco, CA (3)
- Nuevo, CA (2)
- Oceanside, CA (86)
- Ontario, CA (1)
- Pala, CA (1)
- Pauma Valley, CA (7)
- Perris, CA (24)
- Poway, CA (9)
- Ramona, CA (4)
- Rancho Cucamonga, CA (1)
- Rancho Santa Fe, CA (2)
- Rancho Santa Margarita, CA (2)
- Redlands, CA (4)
- Riverside, CA (36)
- San Bernardino, CA (4)
- San Clemente, CA (1)
- San Diego, CA (81)
- San Dimas, CA (1)
- San Jacinto, CA (28)
- San Juan Capistrano, CA (2)
- San Marcos, CA (48)
- Santa Ana, CA (3)
- Santa Fe Springs, CA (1)
- Solana Beach, CA (1)
- Spring Valley, CA (5)
- Sun City, CA (1)
- Temecula, CA (762)
- Temescal Valley, CA (1)
- Trabuco Canyon, CA (3)
- Upland, CA (2)
- Valley Center, CA (18)
- Vista, CA (161)
- Warner Springs, CA (5)
- Wildomar, CA (77)
- Winchester, CA (125)
- Yorba Linda, CA (14)
- Yucaipa, CA (5)
Job Locations and Reviews
Upon arrival performed diagnostic, found transformer to be burnt uo and not sending 24v to circuit board. Primary start was the main short inside of condenser unit, causing fuses to pop and transformer to fail. Replaced all parts and did low voltage repair got system up and running, did not have filters to swap out for client. Verified refrigerant charge in range. Client declined membership, is going through refinance and doesn’t know if they are moving or not. System is operational.
Upon arrival performed diagnostic, found transformer to be burnt uo and not sending 24v to circuit board. Primary start was the main short inside of condenser unit, causing fuses to pop and transformer to fail. Replaced all parts and did low voltage repair got system up and running, did not have filters to swap out for client. Verified refrigerant charge in range. Client declined membership, is going through refinance and doesn’t know if they are moving or not. System is operational.
Upon arrival performed diagnostic, found transformer to be burnt uo and not sending 24v to circuit board. Primary start was the main short inside of condenser unit, causing fuses to pop and transformer to fail. Replaced all parts and did low voltage repair got system up and running, did not have filters to swap out for client. Verified refrigerant charge in range. Client declined membership, is going through refinance and doesn’t know if they are moving or not. System is operational.
Arrived on site to perform spring tune up on a 2011 unit. Condenser located in back yard. Furnace and Evaporator coil in hall closet. cycled unit and replaced dirty filter client supplied. Washed condenser and wiped down unit clean. Found primary starter was burnt up and worn out from use. Secondary motor controls is is weak and out of range of fan terminal. Recommend getting replaced before completely fails. Fan motor is over amping as max is 1.1 and pulling 1.2. Could fails in future due to age and condition. Compressor is pulling 10 amps and max rated for 15.4. Recommend adding compressor booster kit to prolong life of compressor and prevent hard start ups on compressor. Checked refrigerant pressure and were good and cooling at 20 degrees. Unit uses r-22 That is no longer in production. Inspected indoor unit and found it dirty from past years of dirt entering system. Blower is dirty. Filter was replaced. Found one drain line in use and is dirty. No protection on unit. Cycled system
Installation of a 4 ton 16 SEER air conditioning system with high efficiency coil. Basic stripped package with no high flow registers, WiFi thermostat or permits. 1 year maintenance contract is included. Cash Price - $7,236 (cash or check)
Performed AC maintenance on a ACPRO condenser. Systems cooling temperature split is 20 degrees. Indoor blower is amping high and leaking oil. Housing and motor has a heavy amount of dust collected on it. Suggesting replacement. Outdoor coils were chemically cleaned. Compressor and fan amps are ok at this time. Refrigerant levels are ok. System was cycled before leaving.
Arrived on site to perform maintenance on a 2007 lennox unit. Condenser located on side of house. Furnace and Evaporator coil located in attic. Client stated no issues. Cycled unit. Washed condenser coil inside and out. Found primary starter is burnt up and crating loud buzzing noise advised could be starting to go bad. Found secondary motor control completely dead on the compressor terminal and had booster kit added and is the only reason why unit is still starting up. Fan side was good. Run amp on compressor we’re at max due to bad secondary control. Replace to test amp and run amps dropped to 7 amps which is good and in range. Fan motor is operating over max rate and is pulling 1.2 and max rated for 1.1. Advised due to age of unit fan is aware vet working and could fail in future or cause other parts to start to go bad. Checked pressure and found unit to be a tad bit low on charge but ores are still in range just a bit low. Unit is cooling at 24 degrees. Found filter to be dirty
Performed AC maintenance on 28-year-old Lennox condensing unit. Upon my maintenance there were multiple points of concerns that were addressed with Oscar. 1. Measured refrigerant pressures and found that system was extremely low on R22 refrigerant charge. There is a leak somewhere within the refrigeration cycle and system only get lower as time progresses. 2. Outdoor condensing fan motor was beginning to over amp and overheat due to wear and tear of motor 3. Dual secondary motor control is becoming weak due to compressor using more power than needed. This battery will only get weaker as a Compressor continues to run in pull high amperage. 4. Compressor saver kit is completely dead and no longer acting as a steroid booster for the compressor on start up this is also the reason why the compressor keeps locking out on start up After running on a load. 5. Compressor Is it high risk of failing soon due to it locking out on overload because of age and deterioration of winding and valves with
Performed AC diagnostic on 2019 carrier Condenser. Upon my diagnostic client stated that system was refilled approximately a year and a half ago with refrigerant by the builders of the house. She just started using the system again and now the system is no longer cooling upstairs or downstairs. I proceeded to the outdoor unit and found that the system is operational and running on very low amps. I gaged up to the service ports of the condenser and found out the R410a pressures were way below the proper refrigerant charge it is designed to be at. Ultimately there is a leak somewhere within the refrigeration cycle and was addressed The last time they were out there and filled the system with refrigerant. Advised client that a leak dye/sealant needs to be injected into the system to coat the copper line sets in the indoor and outdoor unit to help us pinpoint the location of the refrigerant leak to prevent any further loss. Will be returning in approximately one month to locate leak with U
Preformed Ac diagnostic on 1999 Rheem condenser. Upon my diagnostic Tracy stated that the system was freezing up on suction line of condenser outside. Verified that indoor blower motor is running Although the single secondary motor control that powers it is reading at 11 µF when it should be at 15 µF. Proceeded to outdoor Unit and found that suction line was icing up. Noticed that the suction line insulation was completely stripped while the sun is bearing down on the suction line. Measured refrigerant pressures and found that refrigerant pressures were becoming too cold inside the evaporator coil due to an an air restriction inside the system. Found that the indoor blower motor was completely covered in dust and debris and original filter was completely plugged up and not swapped out enough resulting in dust making it inside evaporator coil and creating a blanket of dirt restricting airflow resulting in colder temperatures inside of the evaporator coil. Client also stated that compr
Performed AC diagnostic on 2016 Lennox Condenser. Upon my diagnostic client stated that system was recharged back in April with 2 pounds of refrigerant and is now apparently no longer cooling the house. Client thought we were associated with home warranty but we do not work with them. Started diagnostic off at Condenser and found that everything is operational. When I measured the refrigerant pressures I found that the system was extremely under charged due to an apparent leak within the system. Also found that duel secondary motor control is becoming week due to compressor running with no refrigerant. Advisor that I leaked I should be injected into the system so that we can pinpoint the location of the leak and repair it for a long term solution. Advised her that any refrigerant dumped into the system right now can’t potential to be lost by the next time I arrive. Recharged System was 6 pounds of refrigerant and injected leak dye into system and will return approximately in one mont
Arrived on site to install and do repairs. Client approved to replace fan motor with a high efficiency motor and adds compressor booster kit and a surge protector on unit. Installed and cycled and system is operational and cooling upon departure. Client is happy with repairs and work done today. System operational upon departure.
Upon arrival system is working and operational, removed fan from condenser to properly clean the coils inside and out removing dirt and debris. Tested electrical on outdoor unit, upon inspection found the capacitor to be weaker then rated values, also found the compressor to be amping high upon start up. Recommended new capacitor and a compressor saver kit. Checked Refrigerant charge in system, system pressure looked good and was within range. Inspected indoor furnace, upon inspection electrical components and control board are functioning properly. Ducts look to be in good condition. Replaced filters and washed washable, noticed filters are heavily impacted with dust and debris, recommended possible filter alternatives increasing the air quality in the home. Upon departure systems are working and operational
Upon arrival system is working and operational, removed fan from condenser to properly clean the coils inside and out removing dirt and debris. Tested electrical on outdoor unit, upon inspection found the capacitor to be weaker then rated values, also found the compressor to be amping high upon start up. Recommended new capacitor and a compressor saver kit. Checked Refrigerant charge in system, system pressure looked good and was within range. Inspected indoor furnace, upon inspection electrical components and control board are functioning properly. Ducts look to be in good condition. Replaced filters and washed washable, noticed filters are heavily impacted with dust and debris, recommended possible filter alternatives increasing the air quality in the home. Upon departure systems are working and operational
Upon arrival system is working and operational, removed fan from condenser to properly clean the coils inside and out removing dirt and debris. Tested electrical on outdoor unit, upon inspection found the capacitor to be weaker then rated values, also found the compressor to be amping high upon start up. Recommended new capacitor and a compressor saver kit. Checked Refrigerant charge in system, system pressure looked good and was within range. Inspected indoor furnace, upon inspection electrical components and control board are functioning properly. Ducts look to be in good condition. Replaced filters and washed washable, noticed filters are heavily impacted with dust and debris, recommended possible filter alternatives increasing the air quality in the home. Upon departure systems are working and operational
Upon arrival system is working and operational, removed fan from condenser to properly clean the coils inside and out removing dirt and debris. Tested electrical on outdoor unit, upon inspection found the capacitor to be weaker then rated values, also found the compressor to be amping high upon start up. Recommended new capacitor and a compressor saver kit. Checked Refrigerant charge in system, system pressure looked good and was within range. Inspected indoor furnace, upon inspection electrical components and control board are functioning properly. Ducts look to be in good condition. Replaced filters and washed washable, noticed filters are heavily impacted with dust and debris, recommended possible filter alternatives increasing the air quality in the home. Upon departure systems are working and operational
Arrived on site to perform spring tune up on a 2008 Goodman unit. Client stated no issues. Washed condenser inside and out. Unit was dirty. Primary control was good as it was replaced. Secondary motor controls is good. Found fan motor over amping and advised could fail due to over working. Start ups were in range recon compressor booster kit to prolong life of compressor and prevent hard start ups. System pressure are good and cooling hole at 21 degrees. Replaced filter as client supplied his own. Blowers assembly and motor are good. Found surge protection on furnace good and active. Cycled system to ensure system operating. Went over all repairs and recommendations. Client is aware how system is running and condition and would like to go with the premium plan and would be coming back to do repairs due to time today. I will call to get him back on schedule Client is aware how system is running and conditions. System is operational and cooling upon departure.
Performed AC tuneup on a carrier condenser. System is cooling 15 degrees. Condensate lines are clear but have no safety switch. Indoor blower is amping ok. Filter is clean. Evaporator coil is a 410A txv metering device. Outdoor coil is a R22 condenser. This is causing inefficient cooling. Compressor is amping high run and start amps. Fan motor is leaking oil. System was cycled before leaving. Customer wants to discuss options on replacing the R22 condenser to have a correctly running system.
Diagnosed system, Found system to be non operational. Found breakers at disconnect to be bad and not letting power through to condenser. System is non operational, client will replace himself.
Diagnosed system, Found system to be non operational. Found breakers at disconnect to be bad and not letting power through to condenser. System is non operational, client will replace himself.
Diagnosed system, Found system to be non operational. Found breakers at disconnect to be bad and not letting power through to condenser. System is non operational, client will replace himself.
Diagnosed system, Found system to be non operational. Found breakers at disconnect to be bad and not letting power through to condenser. System is non operational, client will replace himself.
Upon arrival performed diagnostic on ac. Client states that the fan will just keep running after cycle of cooling. Cycled system on and off, ac kicks on good after delay. Fan is shutting off, client replaced thermostat and it might be showing 1 degrees off. Advised system is running fine, if anything weird happens just visualize thermostat screen and take notes on what happens. System was reset tested and fully functional upon departure.
Upon arrival performed diagnostic on ac. Client states that the fan will just keep running after cycle of cooling. Cycled system on and off, ac kicks on good after delay. Fan is shutting off, client replaced thermostat and it might be showing 1 degrees off. Advised system is running fine, if anything weird happens just visualize thermostat screen and take notes on what happens. System was reset tested and fully functional upon departure.
Upon arrival performed diagnostic on ac. Client states that the fan will just keep running after cycle of cooling. Cycled system on and off, ac kicks on good after delay. Fan is shutting off, client replaced thermostat and it might be showing 1 degrees off. Advised system is running fine, if anything weird happens just visualize thermostat screen and take notes on what happens. System was reset tested and fully functional upon departure.