Plumbing, Air Conditioning, and Cooling Solutions for Fallbrook, CA Homes
Hello, Fallbrook friends! Cool Air Solutions, is your go-to HVAC expert in the heart of the “Avocado Capital of the World.” Nestled in the scenic rolling hills and groves of Southern California, Fallbrook is a community we’re proud to serve. Whether you're enjoying the lush landscapes or the charming local shops, we’re here to ensure your home stays perfectly comfortable year-round.
Give us a call today at 951-234-0748 or visit our contact page to experience the Cool Air Solutions difference!
Plumbing Services in Fallbrook, CA
From worn-out water heaters to slab leaks and stubborn clogs, Cool Air Solutions handles it all. Our licensed plumbers are trained to diagnose and resolve your home’s plumbing problems quickly, and we clean up like we were never there.
-
Water Heater Repair & Replacement: We service all makes and models, including traditional and tankless units, and install new systems with expert care.
-
Leak Detection & Slab Leak Repair: Using advanced tools, we detect leaks quickly and complete repairs with minimal disruption to your home.
-
Pipe Repair & Repiping: We address everything from small leaks to full system repipes using long-lasting materials like copper or PEX.
-
Toilet, Faucet & Shower Repairs: We install and repair modern, water-saving fixtures that improve performance and style.
-
Water Filtration & Softeners: Fallbrook’s hard water is no match for our whole-home filtration and softener systems.
-
Garbage Disposal Services: From jammed blades to full replacements, we’ll restore your disposal in no time.
-
Drain & Sewer Cleaning: We remove tough blockages using camera inspections and hydro-jetting to restore proper flow.
-
Backflow & Pressure Regulation: We protect your water supply and ensure code compliance with reliable safety device installation.
Every plumbing job is backed by our Lifetime Craftsmanship Guarantee, giving you peace of mind and long-term confidence.
Air Conditioning and Cooling Services
- Ductless Mini Split: Ideal for homes without existing ductwork, providing flexible and efficient cooling solutions that can be customized for different zones in your home.
- AC Repair and Maintenance: From minor fixes to major repairs, we ensure your AC unit functions optimally. Regular maintenance helps in preventing breakdowns and extending the lifespan of your system
Heating Services
- Furnaces: Keep your home warm during the cooler months with our professional furnace installation and replacement services.
- Gas Furnace: Efficient and reliable heating solutions using natural gas to keep your home comfortable.
- Oil Furnace: An alternative heating solution for homes without access to natural gas, providing consistent and effective warmth.
- Heat Pump: An energy-efficient solution that provides both heating and cooling, ideal for Fallbrook’s climate.
- Garage Heater: Ensure your garage remains usable year-round with our specialized garage heating solutions.
Thermostat and Control Solutions
- Programmable Thermostat: Allows you to set your HVAC system to operate according to your schedule, enhancing comfort and energy savings.
- Thermostat Manual Directory: Access comprehensive manuals and guides for various thermostat models to ensure optimal usage and troubleshooting.
Why Choose Cool Air Solutions?
Cool Air Solutions is dedicated to delivering exceptional customer service and high-quality HVAC solutions. Our team of highly trained technicians is committed to providing reliable and efficient services tailored to meet your specific needs. We take pride in our work and strive to exceed your expectations with every service call.
Stay Comfortable Year-Round with Cool Air Solutions
Fallbrook’s unique climate requires a reliable HVAC system to maintain a comfortable home environment. Trust Cool Air Solutions to deliver the heating, cooling, and indoor air quality services you need to stay comfortable throughout the year. Whether it's a hot summer day or a chilly winter night, we're here to ensure your home remains a haven of comfort.
Don't wait—call us now at 951-234-0748 or visit our contact page to book your service today!
Recent Jobs and Reviews in Fallbrook, CA
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and trust. Customers consistently praise the company for delivering professional, knowledgeable, and efficient service. A recurring theme is the technical expertise and personable nature of the technicians, who are described as respectful, friendly, and genuinely passionate about their work. Many reviewers highlight the quality of major installations, including complete HVAC system replacements and ductwork, noting impressive speed and precision even under challenging conditions. The company earns strong appreciation for their transparency, thorough documentation, and clear communication about necessary services versus optional ones. Long-term customer loyalty is evident, with clients expressing continued satisfaction over multiple years and repeated service calls. The responsiveness to inquiries and commitment to standing behind their work further reinforces the positive reputation. Overall, the tone is enthusiastic and grateful, with customers feeling valued and confident in the quality and reliability of the service provided.
Fallbrook, CA at a glance
Cool Air Solutions has completed 25 jobs in Fallbrook, CA between May 2021 and August 2021.
The most recent job was on August 2, 2021.
Cool Air Solutions has completed 2 jobs in Fallbrook, CA in the last 12 months. The first job there was in November 2016.
Our Local Reviews by City
- Aguanga, CA (5)
- Aliso Viejo, CA (1)
- Anaheim, CA (5)
- Banning, CA (2)
- Beaumont, CA (5)
- Bonsall, CA (9)
- Buena Park, CA (2)
- Canyon Lake, CA (27)
- Carlsbad, CA (59)
- Carson, CA (1)
- Cathedral City, CA (1)
- Chino, CA (2)
- Chino Hills, CA (4)
- Chula Vista, CA (13)
- Corona, CA (51)
- Del Mar, CA (3)
- Downey, CA (1)
- Eastvale, CA (1)
- El Cajon, CA (8)
- Encinitas, CA (5)
- Escondido, CA (119)
- Fallbrook, CA (65)
- Fontana, CA (2)
- Fountain Valley, CA (2)
- Fullerton, CA (2)
- Garden Grove, CA (5)
- Hacienda Heights, CA (1)
- Hemet, CA (73)
- Homeland, CA (9)
- Huntington Beach, CA (1)
- Irvine, CA (4)
- Jurupa Valley, CA (2)
- La Verne, CA (1)
- Ladera Ranch, CA (1)
- Laguna Hills, CA (5)
- Laguna Niguel, CA (2)
- Laguna Woods, CA (1)
- Lake Elsinore, CA (119)
- Lake Forest, CA (16)
- Lakeside, CA (5)
- Lakewood, CA (1)
- Lemon Grove, CA (1)
- Los Alamitos, CA (1)
- Menifee, CA (203)
- Mission Viejo, CA (8)
- Moreno Valley, CA (26)
- Murrieta, CA (670)
- Newport Beach, CA (1)
- Norco, CA (3)
- Nuevo, CA (2)
- Oceanside, CA (86)
- Ontario, CA (1)
- Pala, CA (1)
- Pauma Valley, CA (7)
- Perris, CA (24)
- Poway, CA (9)
- Ramona, CA (4)
- Rancho Cucamonga, CA (1)
- Rancho Santa Fe, CA (2)
- Rancho Santa Margarita, CA (2)
- Redlands, CA (4)
- Riverside, CA (36)
- San Bernardino, CA (4)
- San Clemente, CA (1)
- San Diego, CA (81)
- San Dimas, CA (1)
- San Jacinto, CA (28)
- San Juan Capistrano, CA (2)
- San Marcos, CA (48)
- Santa Ana, CA (3)
- Santa Fe Springs, CA (1)
- Solana Beach, CA (1)
- Spring Valley, CA (5)
- Sun City, CA (1)
- Temecula, CA (762)
- Temescal Valley, CA (1)
- Trabuco Canyon, CA (3)
- Upland, CA (2)
- Valley Center, CA (18)
- Vista, CA (161)
- Warner Springs, CA (5)
- Wildomar, CA (77)
- Winchester, CA (125)
- Yorba Linda, CA (14)
- Yucaipa, CA (5)
Job Locations and Reviews
Tech arrived on site. Pumped down system. Got access to evap coil. Removed and installed new txv. Pressure tested fittings. Txv was good but pressure was still dropping slowly. Evap coil has oil stains from a refrigerant leak. Pulled vac. Charged refrigerant. Added 1 lbs of 410a. System is now cooling. Informed homeowner of leak. System is operational upon departure.
Tech arrived on site. Checked pressures. They appeared low. Opened up evap coil and found the txv to be icing up. Charge appeared good last visit. No oil stains around unit. Leak detector didn’t find anything. Need to order new valve to get ac going again.
Tech arrived on site. Found the operating pressure of the unit to be low. Inspection revealed the evaporator coil had iced up with a thick block of ice. Was unable to open coil due to ice. Left fan on to thaw out the ice. Will return to diagnose the issue.
Tech arrived on site. Found unit operational but not cooling. Filter was restricted snd condenser was also restricted. Did tune up and cleaned unit. Found the capacitor was weak, causing intermittent issues. Replaced the cap. Once everything was cleaned checked charge. It was good. Unit is operational upon departure. 1 year parts/labor on capacitor.
Upon arrival performed maintenance maintenance on rheem systems. Replaced all filters. Advised client motor has very little play when spinning, bearings are beginning to wear out. Temp splits and refrigerant levels in range. Washed off condenser coils. Tested fuses. Secondary motor controls are in range. Systems are a bit older but amperages on compressor and fan motors are in range. Dusted off all electrical connections. Cycled systems on and off, systems are running and have no trouble starting up. Tested refrigerant levels. 1. Condenser fan motor leaking oil 2. R22 refrigerant 3. Tested refrigerant 4. Washed off coils 5. Swapped filters System is operational upon departure.
Upon arrival performed maintenance maintenance on rheem systems. Replaced all filters. Advised client motor has very little play when spinning, bearings are beginning to wear out. Temp splits and refrigerant levels in range. Washed off condenser coils. Tested fuses. Secondary motor controls are in range. Systems are a bit older but amperages on compressor and fan motors are in range. Dusted off all electrical connections. Cycled systems on and off, systems are running and have no trouble starting up. Tested refrigerant levels. 1. Condenser fan motor leaking oil 2. R22 refrigerant 3. Tested refrigerant 4. Washed off coils 5. Swapped filters System is operational upon departure.
Upon arrival performed maintenance maintenance on rheem systems. Replaced all filters. Advised client motor has very little play when spinning, bearings are beginning to wear out. Temp splits and refrigerant levels in range. Washed off condenser coils. Tested fuses. Secondary motor controls are in range. Systems are a bit older but amperages on compressor and fan motors are in range. Dusted off all electrical connections. Cycled systems on and off, systems are running and have no trouble starting up. Tested refrigerant levels. 1. Condenser fan motor leaking oil 2. R22 refrigerant 3. Tested refrigerant 4. Washed off coils 5. Swapped filters System is operational upon departure.
Upon arrival performed maintenance maintenance on rheem systems. Replaced all filters. Advised client motor has very little play when spinning, bearings are beginning to wear out. Temp splits and refrigerant levels in range. Washed off condenser coils. Tested fuses. Secondary motor controls are in range. Systems are a bit older but amperages on compressor and fan motors are in range. Dusted off all electrical connections. Cycled systems on and off, systems are running and have no trouble starting up. Tested refrigerant levels. 1. Condenser fan motor leaking oil 2. R22 refrigerant 3. Tested refrigerant 4. Washed off coils 5. Swapped filters System is operational upon departure.
Installed condensate pump in crawl space and ran drain loop outside to the front of the home, terminating at the garden hose. Reattached two disconnected ducts under the home. Ran wiring through the drywall to a socket to supply power to the condensate pump. Filled the pump with water and confirmed drainage.
Performed maintenance on a Goodman condenser. Upon arrival customer explains moldy smell from vents, this has been happening for a year now. Inspected condensate lines under the house snd found the condensate line was disconnected under the house and releasing the water into the dirt. There is also a supply duct run that had became disconnected. This duct has been absorbing moisture from the wet dirt and is supplying the house with a foul smell. Outdoor unit was heavily caked in dirt and pollen. The coils were chemically cleaned. Outdoor amperage are ok at this time. System was working before leaving.
Job walk
Collected 1182 as a deposit. 25000 will be financed
Performed AC maintenance on 2000 ICP Condenser. Upon my maintenance there were a few points of concerns there we’re noticed 1. Outdoor Condenser fan motor has significant oil leakage coming from Bearing and can potentially lead to motor locking up overheating 2. Duel secondary motor control is weak on hermetic side terminal 3. High voltage distributor had an ant build up on contact points. This can lead to contact point having an imperfect connection which results in the system not turning on 4. System Contained R22 refrigerant which was completely phased out on January 1, 2020 5. System Has major air Restrictions which resulted in very low superheat reading on my refrigerant gages. This is resulting in colder temperatures inside the evaporator coil which will cause a suction line to ice up overtime 6. Filter needs to be swapped every one to three months Will be sending over maintenance information due to homeowner not being here at the property. Upon departure system is fully opera
Found water In the primary condensate line not draining properly due to lack of a trap on heat pump system. Removed the old primary line and added a trap with a clean out and vent, primed the trap so no water will fill the drain pan and trip the safety switch.
Replaced defective capacitor, stripped and cleaned the high voltage connections on the starter. Tested voltages and amp draws. Inspected fan motor.
Technician arrived on site. Found the upstairs system flat on refrigerant. Got permission to do pressure test leak detection. Was unable to locate the leak. Uv dye was added to the system previously. Used black light and located dye in the evap coil. Ordering coil for warranty. Field supervisor will come out Friday to give estimate on equipment.
Upon arrival custom complaint is no cooling, system is operational upon arrival. Upon inspection there was significant oil around the valve cover, system had little to no refrigerant. After inspection we Proceeded to perform a leak test pressurizing the system, we were able to deuce the leak came from the Schrader core and liquid line flare fitting. Replaced the schrader core and applied nylog onto the suction and liquid line threads. System held pressure. Proceeded to properly vacuum system to below 500 microns. Weighed in 1.7 pounds of R-410A into the system, recharging it. System functioning properly and cooling efficiently upon departure.
Upon arrival custom complaint is no cooling, system is operational upon arrival. Upon inspection there was significant oil around the valve cover, system had little to no refrigerant. After inspection we Proceeded to perform a leak test pressurizing the system, we were able to deuce the leak came from the Schrader core and liquid line flare fitting. Replaced the schrader core and applied nylog onto the suction and liquid line threads. System held pressure. Proceeded to properly vacuum system to below 500 microns. Weighed in 1.7 pounds of R-410A into the system, recharging it. System functioning properly and cooling efficiently upon departure.
Upon arrival custom complaint is no cooling, system is operational upon arrival. Upon inspection there was significant oil around the valve cover, system had little to no refrigerant. After inspection we Proceeded to perform a leak test pressurizing the system, we were able to deuce the leak came from the Schrader core and liquid line flare fitting. Replaced the schrader core and applied nylog onto the suction and liquid line threads. System held pressure. Proceeded to properly vacuum system to below 500 microns. Weighed in 1.7 pounds of R-410A into the system, recharging it. System functioning properly and cooling efficiently upon departure.
Upon arrival custom complaint is no cooling, system is operational upon arrival. Upon inspection there was significant oil around the valve cover, system had little to no refrigerant. After inspection we Proceeded to perform a leak test pressurizing the system, we were able to deuce the leak came from the Schrader core and liquid line flare fitting. Replaced the schrader core and applied nylog onto the suction and liquid line threads. System held pressure. Proceeded to properly vacuum system to below 500 microns. Weighed in 1.7 pounds of R-410A into the system, recharging it. System functioning properly and cooling efficiently upon departure.
Upon arrival performed maintenance on the Lenix heating and air system. Opened up entire doors on condensing unit space washed off all coils and inside of air-conditioning unit. Tested all electrical components. Dusted off all electrical components. Refrigerant levels in range. Electrical fuses in range. Condenser fan motor in range. Replaced merv 16 filter. Cleaned down air handler, dusted off all electrical components. insulation is in very good condti9on same as ducting system. Verified system is operational before departure,.
Upon arrival performed maintenance on the Lenix heating and air system. Opened up entire doors on condensing unit space washed off all coils and inside of air-conditioning unit. Tested all electrical components. Dusted off all electrical components. Refrigerant levels in range. Electrical fuses in range. Condenser fan motor in range. Replaced merv 16 filter. Cleaned down air handler, dusted off all electrical components. insulation is in very good condti9on same as ducting system. Verified system is operational before departure,.
Upon arrival performed maintenance on the Lenix heating and air system. Opened up entire doors on condensing unit space washed off all coils and inside of air-conditioning unit. Tested all electrical components. Dusted off all electrical components. Refrigerant levels in range. Electrical fuses in range. Condenser fan motor in range. Replaced merv 16 filter. Cleaned down air handler, dusted off all electrical components. insulation is in very good condti9on same as ducting system. Verified system is operational before departure,.
Upon arrival performed maintenance on the Lenix heating and air system. Opened up entire doors on condensing unit space washed off all coils and inside of air-conditioning unit. Tested all electrical components. Dusted off all electrical components. Refrigerant levels in range. Electrical fuses in range. Condenser fan motor in range. Replaced merv 16 filter. Cleaned down air handler, dusted off all electrical components. insulation is in very good condti9on same as ducting system. Verified system is operational before departure,.
Replaced very dirty filter. Measured temp splits and refrigerant pressures. Adjusted refrigerant charge by 7 ounces to achieve a higher sub cooling value. Inspected ducting and checked the txv mounted bulb. Tightened down txv compression liquid line connection just as a precaution. I did not notice any odd squeaky sounds at the outdoor unit.