financing Special Offers Call Us Book Online

Winchester, CA

Comfort Starts Here—Heating, Cooling & Plumbing for Winchester Homes and Businesses

Looking for dependable HVAC or plumbing services in Winchester, CA? Cool Air Solutions is your local source for fast, affordable home comfort solutions. Whether you're battling the summer heat, facing a mid-winter chill, or dealing with an unexpected leak, our expert team is just around the corner—and ready to help.

Since 2006, we’ve been helping homeowners in Winchester stay comfortable year-round with precision heating, cooling, and plumbing services. From AC installations to water heater repairs, we handle it all with unmatched craftsmanship and backed-by-our-promises service.

Use our online form or call 951-234-0748 to schedule your service today.

Heating and Air Conditioning in Winchester, CA

Professional HVAC Services for Every Season

Don’t leave your home comfort to chance. Our certified HVAC technicians deliver responsive service and expert solutions, whether you need a seasonal tune-up or a full system replacement. We service all major brands and specialize in high-efficiency installations that save energy without sacrificing performance.

Our HVAC services include:

  • AC installation, replacement & repair

  • Furnace repair & electric furnace installation

  • Smart thermostat upgrades

  • Ductless mini-split systems

  • Heat pumps & hybrid systems

  • Seasonal tune-ups and precision maintenance

  • Airflow balancing and zoning solutions

Every installation comes with our Lifetime Craftsmanship Guarantee, 1-Year Test Drive Guarantee, and No Surprise Pricing. And if your system ever breaks down unexpectedly, we’ve got your back with our 24-Hour Fix-It Guarantee.

Plumber in Winchester, CA

Plumbing Problems? One Call Solves Them All.

When plumbing issues strike, Cool Air Solutions is ready to respond with fast, professional service. Whether it’s a worn-out water heater or a mystery leak behind your wall, we’ll get to the root of the problem and deliver a lasting fix—no mess, no stress.

Our plumbing services in Winchester include:

  • Water heater repair and installation (tank and tankless)

  • Slab leak detection and repair

  • Pipe and valve replacement

  • Toilet, faucet, and shower repairs

  • Garbage disposal service

  • Water filtration and softener systems

  • Pressure regulators and backflow devices

  • Sewer inspection and hydro-jetting

Our licensed plumbing team handles each job with care, using the right tools, the right parts, and the right attitude. No subcontractors. No shortcuts. Just clean, reliable results backed by our Lifetime Craftsmanship Guarantee.

Affordable Comfort, Trusted Service

At Cool Air Solutions, we believe quality should never come with sticker shock. That’s why we offer:

  • Transparent pricing with no upsells

  • Flexible financing options

  • Top-tier systems from trusted brands like Lennox

  • Access to local and federal rebates and incentives

  • Optional Comfort Club membership for year-round maintenance

Our technicians arrive on time, protect your home during every visit, and take the time to explain your options, so you can make the best decision for your home and budget.

Schedule HVAC or Plumbing Service in Winchester Today

Whether you need a quick fix or a total system upgrade, Cool Air Solutions is here to help. We're proud to provide heating, air conditioning, and plumbing services to homeowners across Winchester and the surrounding areas.

Contact us online or call 951-234-0748 to book your appointment today and experience the comfort and care you deserve.

Recent Jobs and Reviews in Winchester, CA

Rated 4.9 out of 5 stars based on 124 customer reviews

Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and trust. Customers consistently praise the company for delivering professional, knowledgeable, and efficient service. A recurring theme is the technical expertise and personable nature of the technicians, who are described as respectful, friendly, and genuinely passionate about their work. Many reviewers highlight the quality of major installations, including complete HVAC system replacements and ductwork, noting impressive speed and precision even under challenging conditions. The company earns strong appreciation for their transparency, thorough documentation, and clear communication about necessary services versus optional ones. Long-term customer loyalty is evident, with clients expressing continued satisfaction over multiple years and repeated service calls. The responsiveness to inquiries and commitment to standing behind their work further reinforces the positive reputation. Overall, the tone is enthusiastic and grateful, with customers feeling valued and confident in the quality and reliability of the service provided.

Winchester, CA at a glance

Cool Air Solutions has completed 25 jobs in Winchester, CA between May 2020 and June 2020.

The most recent job was on June 12, 2020.

Cool Air Solutions has completed 11 jobs in Winchester, CA in the last 12 months. The first job there was in November 2016.

Our Local Reviews by City

Job Locations and Reviews

Luis M.
Luis M. Checked in
Upon arrival found unit unresponsive. Found defective secondary motor control. Replaced with titan HD. Added hardstart kit to system to keep amperages low on compressor on start. Replaced 12x24 & 20x24 filter. System is operational. Have to email customer authorization form for esa.
Winchester, CA 92596
Luis M.
Luis M. Checked in
System #1 Opened up and washed out condenser coils. Primary power distributor is rusting and pitted at contacts. Secondary control rusted at terminal an borderline out of range. Condenser fan motor is leaking excessive oil, this is premature failure. System is very low on charge, evap coil is starting to freeze up. Indoor blower motor is leaking oil with a dirty blower wheel. Returns are undersized. System#2 Opened up and washed outdoor system. Primary power distributor good. Secondary control losing capacity. Outdoor fan motor is leaking oil & bad bearing, premature failure. Running fan motor can cause motor to over heat & seize up. Compressor has high start amps. Indoor blower motor is leaking oil with a very dirty blower wheel Replaced both filters 20x36x1 & 14x14x1. 1. Condenser fan motors leaking oil x2 2. Indoor blower motors leaking oil & bad bearing x2 3. Downstairs system very low on charge, -9 subcool 4. Evap coil starting to freeze. 5. Refrigerant leak. 6. Dirty blow
Winchester, CA 92596
Luis M.
Luis M. Checked in
System #1 Opened up and washed out condenser coils. Primary power distributor is rusting and pitted at contacts. Secondary control rusted at terminal an borderline out of range. Condenser fan motor is leaking excessive oil, this is premature failure. System is very low on charge, evap coil is starting to freeze up. Indoor blower motor is leaking oil with a dirty blower wheel. Returns are undersized. System#2 Opened up and washed outdoor system. Primary power distributor good. Secondary control losing capacity. Outdoor fan motor is leaking oil & bad bearing, premature failure. Running fan motor can cause motor to over heat & seize up. Compressor has high start amps. Indoor blower motor is leaking oil with a very dirty blower wheel Replaced both filters 20x36x1 & 14x14x1. 1. Condenser fan motors leaking oil x2 2. Indoor blower motors leaking oil & bad bearing x2 3. Downstairs system very low on charge, -9 subcool 4. Evap coil starting to freeze. 5. Refrigerant leak. 6. Dirty blow
Winchester, CA 92596
Luis M.
Luis M. Checked in
System #1 Opened up and washed out condenser coils. Primary power distributor is rusting and pitted at contacts. Secondary control rusted at terminal an borderline out of range. Condenser fan motor is leaking excessive oil, this is premature failure. System is very low on charge, evap coil is starting to freeze up. Indoor blower motor is leaking oil with a dirty blower wheel. Returns are undersized. System#2 Opened up and washed outdoor system. Primary power distributor good. Secondary control losing capacity. Outdoor fan motor is leaking oil & bad bearing, premature failure. Running fan motor can cause motor to over heat & seize up. Compressor has high start amps. Indoor blower motor is leaking oil with a very dirty blower wheel Replaced both filters 20x36x1 & 14x14x1. 1. Condenser fan motors leaking oil x2 2. Indoor blower motors leaking oil & bad bearing x2 3. Downstairs system very low on charge, -9 subcool 4. Evap coil starting to freeze. 5. Refrigerant leak. 6. Dirty blow
Winchester, CA 92596
Luis M.
Luis M. Checked in
System #1 Opened up and washed out condenser coils. Primary power distributor is rusting and pitted at contacts. Secondary control rusted at terminal an borderline out of range. Condenser fan motor is leaking excessive oil, this is premature failure. System is very low on charge, evap coil is starting to freeze up. Indoor blower motor is leaking oil with a dirty blower wheel. Returns are undersized. System#2 Opened up and washed outdoor system. Primary power distributor good. Secondary control losing capacity. Outdoor fan motor is leaking oil & bad bearing, premature failure. Running fan motor can cause motor to over heat & seize up. Compressor has high start amps. Indoor blower motor is leaking oil with a very dirty blower wheel Replaced both filters 20x36x1 & 14x14x1. 1. Condenser fan motors leaking oil x2 2. Indoor blower motors leaking oil & bad bearing x2 3. Downstairs system very low on charge, -9 subcool 4. Evap coil starting to freeze. 5. Refrigerant leak. 6. Dirty blow
Winchester, CA 92596
Jimmy G.
Jimmy G. Checked in
Arrived on site to diagnose a no cooling system. New AC system was just added in recently. Upon arrival found thermostat and furnace had power but out door unit did not turn on. Opened electrical compartment found primary control did not halve low voltage. Inspected low voltage wires on condenser. Found wire nut lose and not secured and cut low voltage. Resecured wire nut low voltage was live again and primary engaged and condenser turned on and was operational and cooling. Advised client of simple fix. Vibration May have made wire nut lose and cause to cut low voltage. System is now operational and cooling. Did not collect Any payment due to it being install warranty. Cycled system. System is operational upon departure.
Winchester, CA 92596
Jimmy G.
Jimmy G. Checked in
Arrived on site to diagnose a no cooling system. We have been out to install a new Ac on downstairs unit. Client stated install came out to re rout drain lines and she stated maybe a hour and half up stairs unit started blowing hot air. Client call the office and got us scheduled back out same day and upon arrival client stated system is working fine now and she did call back to cancel but we stated we still just want to inspec and see what’s going on. Upon arrival I client had system running. Went to inspect outdoor unit with client and advised I was gunna get stated and go get my tools. When I came back found compressor had Shut off. Shut system off and checked electrical compartment. Components and refrigerant pressure. Found secondary control was bad. Creating stress and wear on compressor to work even harder. As compressor is at. Ac start up when turn on. Replaced secondary control to test system and checked pressures. Found pressure to be good. Checked temperature split and was
Winchester, CA 92596
Jimmy G.
Jimmy G. Checked in
Arrived on site to diagnose a blank thermostat on a new system install. Found thermostat blank. Spoke over with clients on what happened. They stated just went blank 2 hours later after install. Went and inspected indoor Equipment and drain lines. Found safety float switch is tripped causing thermostat is blank. Found drain line dirty. Primary drain line is clogged. Under skin is clogged. As well P-traps where dirty as well. Vacuumed all drain lines. Used nitrogen to clear lines as well at T coupling. Over all eliminated system having a clogged line. Cycled system to test drainage. Found due to the way installers routed drain line there is no down flow of water allowing it to drain properly. Advised the office as well as clients of issues now and will have install come back out and rout drain line right. Client did want to go forward with adding a safety float switch and replace P-trap with upstairs unit. Units were operational but advised to client to not use downstairs system to pr
Winchester, CA 92596
Jimmy P.
Jimmy P. Checked in
Performed AC diagnostic. During my diagnostic Found that low-voltage T-Stat wiring was disconnected at Line set connecting to furnace circuit board. Respliced low-voltage wiring system and system is fully operational.
Winchester, CA 92596
Miguel P.
Miguel P. Checked in
$16,813.00 Due Upon completion. After rebates $16,438
Winchester, CA 92596
Luis M.
Luis M. Checked in
Upon arrival performed maintenance. Outdoor condenser was completely opened up and washed out. Customer just wanted routine maintenance done hasn’t done in a couple years. A few components have been replaced this past year and parts are still in very good condition. Condenser fan motor leaking oil. Compressor running at very high amps. Refrigerant levels in good condition. System was reset tested and fully functional upon departure.
Winchester, CA 92596
Luis M.
Luis M. Checked in
Upon arrival performed maintenance. Outdoor condenser was completely opened up and washed out. Customer just wanted routine maintenance done hasn’t done in a couple years. A few components have been replaced this past year and parts are still in very good condition. Condenser fan motor leaking oil. Compressor running at very high amps. Refrigerant levels in good condition. System was reset tested and fully functional upon departure.
Winchester, CA 92596
Luis M.
Luis M. Checked in
Upon arrival performed maintenance. Outdoor condenser was completely opened up and washed out. Customer just wanted routine maintenance done hasn’t done in a couple years. A few components have been replaced this past year and parts are still in very good condition. Condenser fan motor leaking oil. Compressor running at very high amps. Refrigerant levels in good condition. System was reset tested and fully functional upon departure.
Winchester, CA 92596
Luis M.
Luis M. Checked in
Upon arrival performed maintenance. Outdoor condenser was completely opened up and washed out. Customer just wanted routine maintenance done hasn’t done in a couple years. A few components have been replaced this past year and parts are still in very good condition. Condenser fan motor leaking oil. Compressor running at very high amps. Refrigerant levels in good condition. System was reset tested and fully functional upon departure.
Winchester, CA 92596
Michael P.
Michael P. Checked in
Diagnostic and repair of the cooling system
Winchester, CA 92596
Jimmy P.
Jimmy P. Checked in
Performed AC maintenance on 14-year-old weather king condensers
Winchester, CA 92596
Michael P.
Michael P. Checked in
Ac performance check up and service cleaning
Winchester, CA 92596
Tyler H.
Tyler H. Checked in
Doing furnace related repairs and an air conditioning maintenance out here in Winchester.
Winchester, CA 92596
Luis M.
Luis M. Checked in
Upon arrival performed maintenance. Outdoor condenser fan motor is leaking oil and has play on shaft. Secondary motor control is out of range. Disconnect box is melting. Amperages on compressor are high on start up. Recommend adding hardstart kit to prolong life of compressor and less wear and tear. Refrigerant levels good. Opened up condenser and washed coils with shampoo. System was reset tested and fully functional upon departure.
Winchester, CA 92596
Luis M.
Luis M. Checked in
Upon arrival performed maintenance. Outdoor condenser fan motor is leaking oil and has play on shaft. Secondary motor control is out of range. Disconnect box is melting. Amperages on compressor are high on start up. Recommend adding hardstart kit to prolong life of compressor and less wear and tear. Refrigerant levels good. Opened up condenser and washed coils with shampoo. System was reset tested and fully functional upon departure.
Winchester, CA 92596
Luis M.
Luis M. Checked in
Upon arrival performed maintenance. Outdoor condenser fan motor is leaking oil and has play on shaft. Secondary motor control is out of range. Disconnect box is melting. Amperages on compressor are high on start up. Recommend adding hardstart kit to prolong life of compressor and less wear and tear. Refrigerant levels good. Opened up condenser and washed coils with shampoo. System was reset tested and fully functional upon departure.
Winchester, CA 92596
Luis M.
Luis M. Checked in
Upon arrival performed maintenance. Outdoor condenser fan motor is leaking oil and has play on shaft. Secondary motor control is out of range. Disconnect box is melting. Amperages on compressor are high on start up. Recommend adding hardstart kit to prolong life of compressor and less wear and tear. Refrigerant levels good. Opened up condenser and washed coils with shampoo. System was reset tested and fully functional upon departure.
Winchester, CA 92596
Jorge C.
Jorge C. Checked in
Performed Ac Maintenance on 2 15 year old systems. Homeowner just moved into the home a year ago, has not used systems very much but feels like they’re working fine. Cycled both systems for cooling. Checked outdoor units electrical and system components. Pulled both condenser fan motor off of units to thoroughly wash out condenser coil. Performed thorough evaluation of systems, concerns with each unit are as follows: DOWNSTAIRS: 1. Compressor is starting up fairly hard 2. Condenser fan motor is overamping, starting to leak oil 3. Condenser coil has a lot of fins that have been bent. Slightly restricting airflow into unit This unit has good refrigerant pressures and is producing a 20 degree split. UPSTAIRS: 1. Condenser fan motor was replaced at 1 point, but is spinning in the wrong direction 2. Condenser fan motor is also not wired in correctly. Recieving a lot of unnecessary power 3. Switched rotation on fan motor and put wires in correct spot to properly evaluate system 4. Pri
Winchester, CA 92596
Jorge C.
Jorge C. Checked in
Performed Ac maintenance on 2015 Goodman system. Cycled system for cooling. Checked outdoor unit electrical and system components. Amp draws on compressor and condenser fan motor are within Range. Amp draws are compressor start up are high at 64 amps, rated for 65 amps. Homeowner did mention that he does believe that his lights dim down a little whenever the unit starts. Secondary motor control is in range but is very close to falling out of range. Primary motor control is in good condition. Pulled condenser fan motor to thoroughly wash out condenser coil inside and out. Refrigerant levels are in range and system is producing a good temperature split. Performed attic inspection. System only has one drain line, has a safety switch on secondary port in coil. Ductwork is properly secured and sealed. Went over findings and recommendations with homeowner. Wants to hold of on any work today and also wants to talk to wife about maintenance program. Cycled system, system is fully operational u
Winchester, CA 92596
Travis R.
Travis R. Checked in
Replace existing system with below listed Equipment. Lowes promo 10% Off expires 5/3 Lowes Card Finance options= 12 Month 0% or 36 Month 5.99% or 60 Month 6.99% or 84 Month 7.99%
Winchester, CA 92596
Request Service
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon

Call For Same Day Service/Emergencies at 951-234-0748 .

By pressing Submit I agree to receive phone, email, or text messages from Cool Air Solutions Heating & Cooling to the provided mobile number and also agree to the Cool Air Solutions Heating & Cooling terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next