Comfort Starts Here—Heating, Cooling & Plumbing for Winchester Homes and Businesses
Looking for dependable HVAC or plumbing services in Winchester, CA? Cool Air Solutions is your local source for fast, affordable home comfort solutions. Whether you're battling the summer heat, facing a mid-winter chill, or dealing with an unexpected leak, our expert team is just around the corner—and ready to help.
Since 2006, we’ve been helping homeowners in Winchester stay comfortable year-round with precision heating, cooling, and plumbing services. From AC installations to water heater repairs, we handle it all with unmatched craftsmanship and backed-by-our-promises service.
Use our online form or call 951-234-0748 to schedule your service today.
Heating and Air Conditioning in Winchester, CA
Professional HVAC Services for Every Season
Don’t leave your home comfort to chance. Our certified HVAC technicians deliver responsive service and expert solutions, whether you need a seasonal tune-up or a full system replacement. We service all major brands and specialize in high-efficiency installations that save energy without sacrificing performance.
Our HVAC services include:
-
AC installation, replacement & repair
-
Furnace repair & electric furnace installation
-
Smart thermostat upgrades
-
Ductless mini-split systems
-
Heat pumps & hybrid systems
-
Seasonal tune-ups and precision maintenance
-
Airflow balancing and zoning solutions
Every installation comes with our Lifetime Craftsmanship Guarantee, 1-Year Test Drive Guarantee, and No Surprise Pricing. And if your system ever breaks down unexpectedly, we’ve got your back with our 24-Hour Fix-It Guarantee.
Plumber in Winchester, CA
Plumbing Problems? One Call Solves Them All.
When plumbing issues strike, Cool Air Solutions is ready to respond with fast, professional service. Whether it’s a worn-out water heater or a mystery leak behind your wall, we’ll get to the root of the problem and deliver a lasting fix—no mess, no stress.
Our plumbing services in Winchester include:
-
Water heater repair and installation (tank and tankless)
-
Slab leak detection and repair
-
Pipe and valve replacement
-
Toilet, faucet, and shower repairs
-
Garbage disposal service
-
Water filtration and softener systems
-
Pressure regulators and backflow devices
-
Sewer inspection and hydro-jetting
Our licensed plumbing team handles each job with care, using the right tools, the right parts, and the right attitude. No subcontractors. No shortcuts. Just clean, reliable results backed by our Lifetime Craftsmanship Guarantee.
Affordable Comfort, Trusted Service
At Cool Air Solutions, we believe quality should never come with sticker shock. That’s why we offer:
-
Transparent pricing with no upsells
-
Flexible financing options
-
Top-tier systems from trusted brands like Lennox
-
Access to local and federal rebates and incentives
-
Optional Comfort Club membership for year-round maintenance
Our technicians arrive on time, protect your home during every visit, and take the time to explain your options, so you can make the best decision for your home and budget.
Schedule HVAC or Plumbing Service in Winchester Today
Whether you need a quick fix or a total system upgrade, Cool Air Solutions is here to help. We're proud to provide heating, air conditioning, and plumbing services to homeowners across Winchester and the surrounding areas.
Contact us online or call 951-234-0748 to book your appointment today and experience the comfort and care you deserve.
Recent Jobs and Reviews in Winchester, CA
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and trust. Customers consistently praise the company for delivering professional, knowledgeable, and efficient service. A recurring theme is the technical expertise and personable nature of the technicians, who are described as respectful, friendly, and genuinely passionate about their work. Many reviewers highlight the quality of major installations, including complete HVAC system replacements and ductwork, noting impressive speed and precision even under challenging conditions. The company earns strong appreciation for their transparency, thorough documentation, and clear communication about necessary services versus optional ones. Long-term customer loyalty is evident, with clients expressing continued satisfaction over multiple years and repeated service calls. The responsiveness to inquiries and commitment to standing behind their work further reinforces the positive reputation. Overall, the tone is enthusiastic and grateful, with customers feeling valued and confident in the quality and reliability of the service provided.
Winchester, CA at a glance
Cool Air Solutions has completed 25 jobs in Winchester, CA between August 2020 and November 2020.
The most recent job was on November 30, 2020.
Cool Air Solutions has completed 11 jobs in Winchester, CA in the last 12 months. The first job there was in November 2016.
Our Local Reviews by City
- Aguanga, CA (5)
- Aliso Viejo, CA (1)
- Anaheim, CA (5)
- Banning, CA (2)
- Beaumont, CA (5)
- Bonsall, CA (9)
- Buena Park, CA (2)
- Canyon Lake, CA (27)
- Carlsbad, CA (59)
- Carson, CA (1)
- Cathedral City, CA (1)
- Chino, CA (2)
- Chino Hills, CA (4)
- Chula Vista, CA (13)
- Corona, CA (51)
- Del Mar, CA (3)
- Downey, CA (1)
- Eastvale, CA (1)
- El Cajon, CA (8)
- Encinitas, CA (5)
- Escondido, CA (119)
- Fallbrook, CA (65)
- Fontana, CA (2)
- Fountain Valley, CA (2)
- Fullerton, CA (2)
- Garden Grove, CA (5)
- Hacienda Heights, CA (1)
- Hemet, CA (73)
- Homeland, CA (9)
- Huntington Beach, CA (1)
- Irvine, CA (4)
- Jurupa Valley, CA (2)
- La Verne, CA (1)
- Ladera Ranch, CA (1)
- Laguna Hills, CA (5)
- Laguna Niguel, CA (2)
- Laguna Woods, CA (1)
- Lake Elsinore, CA (119)
- Lake Forest, CA (16)
- Lakeside, CA (5)
- Lakewood, CA (1)
- Lemon Grove, CA (1)
- Los Alamitos, CA (1)
- Menifee, CA (203)
- Mission Viejo, CA (8)
- Moreno Valley, CA (26)
- Murrieta, CA (670)
- Newport Beach, CA (1)
- Norco, CA (3)
- Nuevo, CA (2)
- Oceanside, CA (86)
- Ontario, CA (1)
- Pala, CA (1)
- Pauma Valley, CA (7)
- Perris, CA (24)
- Poway, CA (9)
- Ramona, CA (4)
- Rancho Cucamonga, CA (1)
- Rancho Santa Fe, CA (2)
- Rancho Santa Margarita, CA (2)
- Redlands, CA (4)
- Riverside, CA (36)
- San Bernardino, CA (4)
- San Clemente, CA (1)
- San Diego, CA (81)
- San Dimas, CA (1)
- San Jacinto, CA (28)
- San Juan Capistrano, CA (2)
- San Marcos, CA (48)
- Santa Ana, CA (3)
- Santa Fe Springs, CA (1)
- Solana Beach, CA (1)
- Spring Valley, CA (5)
- Sun City, CA (1)
- Temecula, CA (762)
- Temescal Valley, CA (1)
- Trabuco Canyon, CA (3)
- Upland, CA (2)
- Valley Center, CA (18)
- Vista, CA (161)
- Warner Springs, CA (5)
- Wildomar, CA (77)
- Winchester, CA (125)
- Yorba Linda, CA (14)
- Yucaipa, CA (5)
Job Locations and Reviews
2nd opinion on cracked heat exchanger. Customer is going to let me know what home warranty is going to do
Performed furnace maintenance on 2001 Goodman heater. All my maintenance there were a few points of concerns that were addressed with the homeowner. 1. Found the heat exchanger had cracks on the eyelids of all three chambers. 2. Static pressure on system was .78 when design static pressures .12 this is exceeding it tremendously. This is caused by low Airflow and will damage the heat exchanger causing over heating. 3. Indoor blower motor leaking oil from bearing this can lock up or overheat causing a failure in cooling and heating 4. Flame sensor has oxidized and is in very bad condition this component is responsible for sensing flames coming off of the burner 5. Hot service igniter has hotspots and carbon buildup 6. Indoor blower cabinet is covered in dust and dirt due to 1 inch filter not stopping enough dust particles. This is causing scroll wheel to become caked in dust and debris 7. Evaporator coil pan is either cracked or rusted out due to water dripping down internal into the ind
Arrived on site to do repairs on a 2012 Goodman furnace. Will be replacing bad circuit. Replaced and cycled system in heating and cooling to ensure system operating properly with new board. Recommend adding surge protectors to both units to protect system from getting damaged from electrical surges or power outages that can damage or short out system. Client did approve to add surge protectors. Installed furnace surge protector and due to clients having to leave will have to return to install condenser surge protectors. Collected full amount of $1180 no amount will be due when we return to install parts on condenser. Client is aware system is operational and heating and cooling. System is operational upon departure.
Arrived on site to perform diagnostic on a 2001 goodman furnace. Furnace located in attic. Client stated we were just out yesterday day and they stated after previous tech left no heat or the fan wouldn't turn on. But once they cycled Ac the fan turn on and fan mode in On mode fan will operate but not in heat inspected unit and found all connections good and secured. Tested for voltage on inducer, pressure switch, gas valve and all safety switches. Found out that gas valve is not receiving 24 voltage. Test circuit board for proper operation and to see if the board would send 24v to gas valve and it is not. Inspected back of board and found some dark tone discoloration spots on board and board may have a intermittent issues and will work and then not work properly. Advised client of finding and why heater is not working properly. Over all found circuit board is the issue and due to part house close and being the weekend will have to order board Monday and office will client a call to ge
Performed combo tune up on 16 year old Bryant system. Checked indoor and outdoor unit components. Cycled system for heating and cooling modes. Temperature rise across heat exchanger is within range. Temperature split in cooling mode is within range. Indoor blower motor is slightly dirty. Secondary motor control for indoor fan motor is out of range. Previous guy that had done maintenance from another company had already recommended replacing it and she had ordered it online. Asked if I could replace it today but I advised that we can not install parts that are not purchased through us due to liability. Cleaned off platform as well as furnace exterior. Pulled evap cover and inspected heat exchanger. Several hot spots throughout each chamber. Checked outdoor unit electrical and system components. Compressor and condenser fan motor are pulling in high amperage. Condenser fan motor has started to leak out oil and is running hard and hot. Secondary motor control is in range for compressor an
Arrived on site to diagnose exposed thermostat wires on unit. We were last out and did repairs. Upon arrival found unit operational. Client was just concerned due to the chewed up exposed thermostat wires and would like to ensure system is operational and no issues would occur. Found low voltage thermostat wires chewed up and exposed. Which is not replayed to the repairs done in past. Advised client we can repairs low voltage wires and get system operational. Client is aware system is operational just wanted to ensure wires wouldn’t cause any damage to system. Client approved to go forward with repairing low voltage wires. Cycled system to ensure system operating. Checked amp drawls on compressor and fan motor. Found compressor is having high start up as it’s pulling 51 on start up and max rated for 64. Recommended adding a compressor booster kit to help reduce high start up and help preserve compressor and prolong ice of unit it self. Client did declined other recommended work a
Arrived on site to perform maintenance on 2 12 year old systems. Cycled furnaces for heat. Checked indoor units electrical and system components. Blew off insulation off of platform, as well as blew off all dust on furnaces and inside heat and blower compartments. Flame sensors are both clean. Blower wheels have slight dust build up on them. Both blower motors are leaking quite a bit of oil and working hard. Temperature rise on both units is within allowed range. Static pressures are above allowed range. Replaced all 1 inch filters. Condensation lines do not have any condensation switches and secondary port on both units just drains right into the drain pan. Downstairs pressure switch is having trouble closing some time and will not allow furnace to start, pressure switch should be replaced. Went over findings and recommendations with homeowner. Discussed the importance of having heat exchanger thoroughly checked and inspected. Went over findings and recommendations. Homeowners are ha
Also includes complimentary Rossi dampers in main trunks to push air to kids room
Performed AC diagnostic on 2004 Goodman condensing unit. Upon my diagnostic I came across a few points and concerns that were addressed with the homeowner. Goodman unit- 1. Secondary motor control was blown due to high amperage pull of compressor. 2. Found that system refrigerant levels were under charged due to leak in refrigeration cycle. 3. Compressor amperage exceeding max data plate amps. 4. System contains R22 refrigerant which was phased out January 1, 2020. 5. Indoor blower motor leaking oil in causing higher energy consumption and overheating windings. 6. High voltage relay contained burn marks and pitting on contact points. 7. Evaporator coil did not have secondary float switch to prevent flooding in drain pan 9. Static pressure was exceeding .15 due to restricted airflow across system Mr. Whitefield has reviewed his options and has consider replacing system install will take place soon
Arrived on site to perform spring tune up on 2 2006 system. Condenser located in back yard. Furnace and evaporator coil located in attic. Client stated no issues as she recently moved in and previous owners provided maintenance plan. Had client cycled cooling mode on both. Washed both condenser inside and out. Units really dirty advised to client to no let’s dog go and pee on condenser as they could cause issues or create a leak cause of them peeing on condenser. Fan motors ton are leaking oil from over working. Motor is leaking oil down shaft of motors. Checked electrical compartment and components. Found primary starter for upstairs was really burnt up over years of wear, downstairs had dark tone discoloration. Found both secondary motor controls all rusted up and starting to corroded. Recommend replacing as spades are rusting up as well and once fully rusted up components will not make contact and will not operate out door units. Upstairs unit just below range as it’s a little
Performed diagnostic on 6 year old system. Homeowner states that her system does not heat the upstairs. It works perfectly fine for the downstairs, but the upstairs doesn’t have any air coming out of vents when in heat mode. System is a single stage unit with 2 thermostats/zones. Cycled upstairs thermostat for heat. System is unresponsive and does not kick on. Tested wires from thermostat to zone board, they are good but zone board not recieving heat command for upstairs unit. Jumped command at thermostat, system kicked on and started heating. Upstairs Thermostat is not sending heat command. Thermostat needs to be replaced. Went over findings with homeowner and went over thermostat options that we carry. Homeowner states Her brother is an electrician and she will be buying a thermostat and having him install it. Recommended maintenance program. Upstairs system is not operational for heat upon departure.
Performed AC maintenance on 2017 Lennox condensing unit
Installation of a downflow Bronze 16 SEER Package, payment will be received with cashiers check.
Getting a system up and running out here in Winchester
14 seer basic heating and air system
NO COOL. Found system non operational upon arrival. Customer says unit runs but doesn’t really cool. Checked system and found unit outside not running. Checked for power and found 240 at disconnect and at contactor. Checked compressor and found it seized at this time. Offered customer options. Customer wants replacement options. Appointment set from 2-4 today. Unit not operational upon departure.
Upon arrival performed diagnostic. Found system non responsive on cooling mode. Secondary control was out of range causing compressor and fan motor to not kick on. Replaced moto control got system going. Refrigerant levels very good. Found compressor to be pulling 42.7 amps off the start, added booster kit amperages down at 22. Fan motor was leaking oil. Customer wants to get some time out of the system before replacing, so chose a full condenser rebuild. Brand new primary power distributor, old one was pitted and burned badly at contacts. Programmed high efficiency slow start motor for 825 rpm. System was reset tested and fully functional upon departure.
Upon arrival performed diagnostic. Found system non responsive on cooling mode. Secondary control was out of range causing compressor and fan motor to not kick on. Replaced moto control got system going. Refrigerant levels very good. Found compressor to be pulling 42.7 amps off the start, added booster kit amperages down at 22. Fan motor was leaking oil. Customer wants to get some time out of the system before replacing, so chose a full condenser rebuild. Brand new primary power distributor, old one was pitted and burned badly at contacts. Programmed high efficiency slow start motor for 825 rpm. System was reset tested and fully functional upon departure.
Upon arrival performed diagnostic. Found system non responsive on cooling mode. Secondary control was out of range causing compressor and fan motor to not kick on. Replaced moto control got system going. Refrigerant levels very good. Found compressor to be pulling 42.7 amps off the start, added booster kit amperages down at 22. Fan motor was leaking oil. Customer wants to get some time out of the system before replacing, so chose a full condenser rebuild. Brand new primary power distributor, old one was pitted and burned badly at contacts. Programmed high efficiency slow start motor for 825 rpm. System was reset tested and fully functional upon departure.
Upon arrival performed diagnostic. Found system non responsive on cooling mode. Secondary control was out of range causing compressor and fan motor to not kick on. Replaced moto control got system going. Refrigerant levels very good. Found compressor to be pulling 42.7 amps off the start, added booster kit amperages down at 22. Fan motor was leaking oil. Customer wants to get some time out of the system before replacing, so chose a full condenser rebuild. Brand new primary power distributor, old one was pitted and burned badly at contacts. Programmed high efficiency slow start motor for 825 rpm. System was reset tested and fully functional upon departure.
Inspected the system for faults and replaced faulty component
WATER LEAK. Found system operational upon arrival. Customer stated unit is leaking water in bathroom light fixture. Inspected system to check for possible low charge, cracked drain pan, or condensation line restrictions. Found condensation lines restricted. Cleared with customer approval. Customer added month to month esm. Unit operational upon departure.
Arrived on site to perform spring tune up on 2 2007 aire-flo system. Condensers located in back yard. Furnace and evaporator coil located in attic. Client stated no issues just wanted to see how system are running and there condition since he did have some issues in past with furnace and had some repairs done few years back. Had client cycle both in cooling mode. Both systems were operational. Washed out condenser coil inside and out on both systems. Fan blades, bearings, and motor. Both motors have been leaking oil down shaft in past from working hard in previous years. Checked electrical compartment and components. Found both primary controls have dark tone discoloration and burnt marks from self wear of system operating. Recommend replacing primary to prevent system staying on once pitting arch and get stuck and system will not shut off. Secondary motor control on both systems are good. Down stair systems has a booster kit that’s existing but may. It be operational as compressor
Client reports that their system is blowing warm air and the outdoor unit is humming. Findings: (1) Opened up the service and found the battery cap has popped. (2) Replaced the cap and tested the system. (3) Let the system run for about 5 minutes. Found that the condenser fan motor is operating within manufacturer specifications. Found the compressor is not operating within manufacturer specifications. The compressor is over amping and this may be the reason to why the older cap failed in the first place. When a motor over amps it will overheat and usually begins to damage components tied to it. (4) Advised the client of the situation. He understands and is waiting for the home warranty program to start next month. Notes: (1) Unknown how long the compressor will last as it continues to over amp.
Performed AC diagnostic on 2001 condensing unit. Upon my diagnostic I found that indoor blower was on and blowing out ambient hot air. Further investigation shows on the outdoor unit the outdoor fan motor was not energized and spinning although compressor was on. Found that the secondary motor control was blown on fan side terminal along with fan motor leaking oil and over Amping. System contains R22 refrigerant which it was 1 pound low and is a phased out refrigerant as of January 1, 2020. Also did hear that high voltage relay was admitting very loud buzzing noise from low-voltage coil. Replaced outdoor condensing fan motor and secondary motor control and added approximately 1 pound of R22 refrigerant to correct, This indicates that there is a leak somewhere present within the system and a leaked dye drop will be required as of next charge When refrigerant leaks. Upon departure system is fully operational and cooling with a 22° split And condenser coil’s were cleaned off along wi