Warner Springs CA Air Conditioning and Heating Services

Our team's mission is to improve the lives of our clients by providing the most reliable, efficient and comfortable environment in the home and workplace. All with old school manners, work-ethic and customer service!

Cool Air Solutions has provided Warner Springs CA air conditioning and heating solutions since 2006. Our services include installation, repair, maintenance and more for residential and commercial clients.

Read our reviews to see why your Warner Springs CA neighbors call us first when they need help making or keeping their home comfortable.

Recent Jobs and Reviews in Warner Springs, CA

Rated 5.0 out of 5 stars based on 5 customer reviews

Our Local Reviews by City

Job Locations and Reviews

Brent L.
Brent L. Checked in
Client stated no heating -One vent was closed causing the system to get very hot -Blower motor was extremely dirty -There was no filter in place -Flame sensor was extremely dirty -Blower was cleaned and a sediment trap was installed -System has been tested multiple times and I currently running properly -Client is now apart of our comfort club
Warner Springs, CA 92086
Brent L.
Brent L. Checked in
Technician arrived to perform furnace tune up for 5 year old system -Capacitor is reading proper Microfarads -Blower motor is not drawing too much power, however the blower compartment is very dirty and a cleaning is recommended to boost efficiency -There is also no gas sediment trap, so all the sediment is going directly into the gas valve and can potentially clog it -Suction line also needs to be insulated, as having if exposed will throw refrigerant levels off and cause inefficient cooling -Filters were replaced, client provided -System is still in good condition, minor repair need to be made to make it efficient as possible
Warner Springs, CA 92086
Jimmy G.
Jimmy G. Checked in
Arrived on site to perform heating tune up on a 2002 ducane unit. Client stated no issues and unit is operational. Advised unit is operating but is inefficient and would recommend replacement. He’s been keeping alive doing repairs. He is aware and unit is operational upon departure.he stated he just waiting for it to fail since this is his second day home and is not always here. Cucumber it and unit is operational.
Warner Springs, CA 92086
Tony R.
Tony R. Checked in
When I arrived at house, I was told condenser unit didn’t turn on. I went directly to thermostat to watch system fail. I turned cooling on, and went to condenser unit. Opened condenser cabinet and started checking all my electrical components. Motor control was reading full, electronic fan motor was just installed not too long ago. I then checked windings on starter and took off my 24v legs. To de energize system, and I put legs back on and system took off. The starter was smoking when I put legs back on. The starter is failing when giving a call for cool. The owner and I turned on system and shut off system plenty of times. We wanted to make sure that it would work In a call for cooling. The system worked every time. Owner is ok with replacing part whenever I can return to install. Will get part ordered to install. Charging for diagnostic only today.
Warner Springs, CA 92086
Jorge C.
Jorge C. Checked in
Performed diagnostic on 4 year old unit. Homeowner states system is not cooling, and he noticed that the outdoor fan has not been turning on. Cycled system for cooling. Outdoor condenser fan motor is unresponsive, rest of unit is turning on normally. Checked outdoor unit electrical and components. Found a dead secondary motor control that was not powering on fan motor correctly. Advised homeowner, put in a temp part to power unit on and fully evaluate system. With new part in unit, condenser motor turned on and system started cooling. System producing proper temperature split. Amp draws within range. Compressor start up amperage was higher than we’d like, but within range. Filter was just replaced and is clean. No surge protection on unit. Went over findings and recommendations with homeowner and wife over the phone. Want to take care of immediate repair and maintenance program today, and take care of other recommendations in near future. Secured new secondary motor control in system
Warner Springs, CA 92086
Review
Quick, efficient and informative!
Tim - Warner Springs, CA 92086
Luis M.
Luis M. Checked in
Upon arrival performed diagnostic, found secondary control completely Low. Added a testing part to test entire system. Compressor has a start up amp of 71 out of 77. Advised client he can help system with adding softener kit for compressor. Condenser fan motor is discoloring the paint on side of motor due to overheatment. Client wanted to do the bare minimum. Will call us if ever wants to do Memebrship. But not in the position to do that right now.
Warner Springs, CA 92086
Luis M.
Luis M. Checked in
Upon arrival performed diagnostic, found secondary control completely Low. Added a testing part to test entire system. Compressor has a start up amp of 71 out of 77. Advised client he can help system with adding softener kit for compressor. Condenser fan motor is discoloring the paint on side of motor due to overheatment. Client wanted to do the bare minimum. Will call us if ever wants to do Memebrship. But not in the position to do that right now.
Warner Springs, CA 92086
Luis M.
Luis M. Checked in
Upon arrival performed diagnostic, found secondary control completely Low. Added a testing part to test entire system. Compressor has a start up amp of 71 out of 77. Advised client he can help system with adding softener kit for compressor. Condenser fan motor is discoloring the paint on side of motor due to overheatment. Client wanted to do the bare minimum. Will call us if ever wants to do Memebrship. But not in the position to do that right now.
Warner Springs, CA 92086
Luis M.
Luis M. Checked in
Upon arrival performed diagnostic, found secondary control completely Low. Added a testing part to test entire system. Compressor has a start up amp of 71 out of 77. Advised client he can help system with adding softener kit for compressor. Condenser fan motor is discoloring the paint on side of motor due to overheatment. Client wanted to do the bare minimum. Will call us if ever wants to do Memebrship. But not in the position to do that right now.
Warner Springs, CA 92086
Madison H.
Madison H. Checked in
Upon arrival installed new motor. Verified rotation and amps. Tested system. System is operational upon departure.
Warner Springs, CA 92086
Madison H.
Madison H. Checked in
Upon arrival, found 1 15 year old system. Began by checked electrical. Capacitor and compressor are okay. Condenser fan motor is failing. Charge is okay. Temp split is good. Got access to indoor unit. No emergency drain pan installed. Flushed drain line. Checked indoor motor. Changed filter. Unit is operational upon departure.
Warner Springs, CA 92086
Review
It’s a pleasure dealing with someone like jimmy.
Mario - Warner Springs, CA 92086
Jimmy P.
Jimmy P. Checked in
Preformed furnace repairs on Ducane heater. Installed new blower and outdoor/indoor surge protection. System is fully operational and heating properly upon departure.
Warner Springs, CA 92086
Jimmy P.
Jimmy P. Checked in
Performed furnace maintenance on 2007 Ducane heater. Upon arrival Mario stated that the system did not work early in the morning when he tried using the heater. Ran system before starting in system fired up properly and began to heat. Although during the maintenance I did find that the indoor blower motor had significant oil leakage and the single secondary motor control that powers the motor is significantly out of range rating 1.8 MFD which is too low. The motor is not moving enough air capacity across the heat exchanger which will result in it getting too hot as well. Recommend that surge protection is also installed To protect the circuitboard and any sensitive components from power surges that can be damaging. Ordered indoor blower motor and will be returning one part is in hand.
Warner Springs, CA 92086
Jimmy P.
Jimmy P. Checked in
Performed AC diagnostic on 1999 Goodman condenser. Upon my diagnostic client stated that the system stopped working about a week ago he’s not sure if the capacitors bad. Upon my diagnostic I found multiple points of concerns that were addressed with Woody. 1. Compressor windings are no longer good and are instantly causing the breaker to trip or pop the fuses. 2. Duel secondary motor control has been blown on both fan and hermetic side terminals 3. Power disconnect was no longer sending out load to condenser. 4. Starter showed signs of painting and burn marks on contact points 5. System Contained a Phased out R22 Refrigerant As of January 1, 2020 Discuss the full condition of the system with Woody and he plans on putting the house on the martlet. We are going to give him his options whether or not he would like to replace the R22 compressor or replace the ac side of the system. Upon departure collected only diagnostic fee and supervisor will be getting back to him about replacement o
Warner Springs, CA 92086
Luis M.
Luis M. Checked in
Upon arrival performed diagnostic on goodman system. System was low on charge, added 1 lb of r410a and added leak dye to system. Cooling dropped down to 52 degrees. Replaced secondary motor control that was out of range. System is operational upon departure.
Warner Springs, CA 92086
Luis M.
Luis M. Checked in
Upon arrival performed diagnostic on goodman system. System was low on charge, added 1 lb of r410a and added leak dye to system. Cooling dropped down to 52 degrees. Replaced secondary motor control that was out of range. System is operational upon departure.
Warner Springs, CA 92086
Luis M.
Luis M. Checked in
Upon arrival performed diagnostic on goodman system. System was low on charge, added 1 lb of r410a and added leak dye to system. Cooling dropped down to 52 degrees. Replaced secondary motor control that was out of range. System is operational upon departure.
Warner Springs, CA 92086
Luis M.
Luis M. Checked in
Upon arrival performed diagnostic on goodman system. System was low on charge, added 1 lb of r410a and added leak dye to system. Cooling dropped down to 52 degrees. Replaced secondary motor control that was out of range. System is operational upon departure.
Warner Springs, CA 92086
Michael P.
Michael P. Checked in
Inspected upstairs cassette for operation and measured temperatures. Adjusted fan settings to circulate, recommending leaving the system set to cool at 80 so that when the loft is occupied there is not such a large demand to pull down the temperature quickly. Checked filter. Also recommending drapes or shutters for the 4 large windows to help alleviate the heat load upstairs.
Warner Springs, CA 92086
Justin P.
Justin P. Checked in
Walk through
Warner Springs, CA 92086
Jimmy P.
Jimmy P. Checked in
Circuit board was replaced And system began heating with a 40 degree temp rise. Board is warranty for 1 year and system is fully operational upon departure
Warner Springs, CA 92086
Review
The technicians presented an in depth analysis of possible issues and resultant issue. Very informative!
Mario - Warner Springs, CA 92086
Jimmy P.
Jimmy P. Checked in
Performed AC diagnostic on 2007 Ducane Condenser. Upon my diagnostic Mario stated that just a couple months ago The heater had issues with the circuitboard and it needed to be replaced and now the AC doesn’t turn on. The first place I went was to the thermostat and turned the system on to cooling and there was a tremendously long delay. Removed thermostat and jumped out cooling and everything fired up. Proceeded to the addict define that the system is a dedicated horizontal Ducane Inspected the circuitboard and found multiple burns and heat spots. Also found that the indoor blower motor was leaking significant oil from the bearing. Inspected outdoor unit and measured refrigerant pressures to find that the system has major air Restrictions. Refrigerant charge checked out although it does have a Phased out refrigerant called R22. Measured duel secondary motor control that powers compressor and fan and found that it was weak on the compressor side. High-voltage relay was also pitted on
Warner Springs, CA 92086
Michael P.
Michael P. Checked in
Installed daikin 1 thermostats and translating hubs. Manually configured thermostats for operation.
Warner Springs, CA 92086
Jose C.
Jose C. Checked in
18 months 0% interest or 3% cash discount
Warner Springs, CA 92086
Jimmy G.
Jimmy G. Checked in
Arrived on site to perform spring tune up on a 2004 unit. Condenser located on side of home. Furnace and Evaporator coil located in attic. Washed condenser inside and out. Fan motor is leaking my oil from self wear. Primary was good and secondary is good as it was replaced last year. Unit has existing compressor booster kit. Compressor amp are high from age and wear on compressor. Fan motor is pulling high amps draws as well and why motor is leaking oil refrigerant pressure are stable and cooling home at 22 degrees. Indoor unit. Blower assembly is really dirty and with oil. Motor has been leaking oil and could fail in future. Secondary motor control is in range. Evaporator coil is dirty from lack of filter change out. Advised to stay on top of filter cause dirt could clogged up Evaporator coil and drain lines. Temperature split is good and cooling at 22 degrees. Cycled unit. Client is aware of how system is running and it’s condition. Client did declined recommended work at this tim
Warner Springs, CA 92086
Review
Great service and I trust Michael Pierson
Gudrun - Warner Springs, CA 92086
Review
Very good friendly service
Phet - Warner Springs, CA 92086
Your Residential Air Conditioning & Heating Expert

Cool Air Solutions services all makes & models. We offer a FREE ESTIMATE for unit replacement.

Book Now