Premium HVAC, Plumbing & Indoor Air Quality in Riverside—With Guarantees That Actually Mean Something
In a vibrant city like Riverside, where triple-digit summers meet chilly winter nights, home comfort is non-negotiable. Whether you're upgrading to a high-efficiency AC, fixing a slab leak before it spreads, or improving the air your family breathes, Cool Air Solutions is the name Riverside homeowners trust for lasting results—and real protection.
We bring a deep understanding of Riverside’s homes, climate, and common system challenges, delivering professional HVAC, plumbing, and indoor air quality (IAQ) services with unmatched guarantees and zero gimmicks.
Ready to take control of your comfort? Book your service now using our easy online form or call 951-234-0748 to schedule your appointment in Riverside.
HVAC Services in Riverside, CA
When the heat hits hard in Riverside, your AC needs to keep up. When the winter chill rolls in, your heating system shouldn’t skip a beat. At Cool Air Solutions, our licensed HVAC pros repair, install, and maintain systems that work smarter—not harder—to keep your home comfortable year-round.
- AC Repairs & Diagnostics: Loud noises? Weak airflow? We identify and fix AC issues fast—often on the same day.
- High-Efficiency AC Installations: We install quiet, reliable cooling systems tailored to your home’s layout and your energy-saving goals.
- Furnace Services: Whether gas or electric, we repair and install heating systems that deliver steady, safe warmth even on Riverside’s coldest nights.
- Heat Pump Systems: Cut energy use and simplify your system with all-in-one heating and cooling efficiency.
- Ductless Mini-Splits: Perfect for room additions, offices, or homes without ducts, these compact systems offer flexible, zoned comfort.
- Smart Thermostat Upgrades: Control your indoor climate from anywhere, lower energy bills, and maximize comfort with Wi-Fi-enabled thermostats.
- HVAC Maintenance Plans: Our seasonal tune-ups improve performance, prevent breakdowns, and extend the life of your system.
- Ductwork & Airflow Solutions: We correct airflow issues and seal leaky ducts to eliminate hot and cold spots and save energy.
Every installation is backed by our industry-exclusive Lifetime Craftsmanship Guarantee, 1-Year Test Drive, No Lemon Guarantee, No Surprise Pricing, and our 24-Hour Fix-It Guarantee—if we can’t restore your comfort in a day, your hotel stay is on us.
Plumbing Services in Riverside, CA
Riverside’s aging plumbing infrastructure, hard water, and changing water pressure can take a toll on your home. Whether it’s a leaking pipe, a corroded valve, or a faulty water heater, our licensed plumbers deliver fast, precise repairs and installations that last.
- Water Heater Services: From pilot issues to full replacements, we handle tank and tankless water heater repairs and installs.
- Slab Leak Detection: If your floors feel warm or your water bill spikes, we’ll locate and fix the problem without tearing up your home.
- Pipe Repair & Repiping: We replace old, damaged, or leaky pipes with modern copper or PEX solutions that improve pressure and reliability.
- Toilets, Faucets & Fixtures: We repair or replace worn-out fixtures with water-efficient options that save water and elevate style.
- Water Softeners & Filtration Systems: Fight back against Riverside’s hard water with systems that protect your plumbing and improve taste.
- Drain Cleaning & Sewer Services: Clear blockages and restore flow with camera inspections and powerful hydro-jetting.
- Garbage Disposal Services: Whether it's jammed, leaking, or just outdated, we’ll get your disposal working like new.
- Pressure Regulation & Backflow Devices: Protect your home and stay code-compliant with expertly installed valves and regulators.
As always, all plumbing work is backed by our Lifetime Craftsmanship Guarantee.
Indoor Air Quality (IAQ) Services in Riverside
Air quality in Riverside can be affected by seasonal wildfires, dust, and pollen. Our IAQ services help improve your home’s health and protect your HVAC system at the same time.
- Whole-Home Air Purifiers: Eliminate allergens, odors, bacteria, and airborne pollutants.
- High-Efficiency Media Filters: Capture more particles while improving airflow and protecting your HVAC system.
- Humidity Control Systems: Maintain optimal moisture levels with whole-home humidifiers and dehumidifiers.
- Duct Cleaning & Sealing: Clean, seal, and optimize ducts to improve indoor air and reduce waste.
- Energy-Efficient Ventilation: Bring in outdoor air safely without sacrificing comfort.
Why Riverside Homeowners Choose Cool Air Solutions
We don’t just fix your problem—we protect your home. Cool Air Solutions has earned the trust of thousands of Riverside families by showing up, doing clean work, and honoring every promise we make.
- We understand Riverside. We tailor every solution to local needs—from hard water to heatwaves.
- We don’t send strangers. Our techs and plumbers are employees—fully trained, background-checked, and held to our high standards.
- We’re not here to upsell. You get honest options, clearly explained, and the final decision is always yours.
- We back it all up. Every job includes our full suite of written guarantees.
- We’re consistently top-rated. With over 8,000 five-star reviews, we’ve built our business on referrals and repeat customers who know they can count on us.
Schedule HVAC, Plumbing, or IAQ Service in Riverside Today
Whether it’s time for a system upgrade, a seasonal tune-up, or an emergency repair, Cool Air Solutions delivers the results Riverside homeowners rely on.
Book your appointment online or call 951-234-0748 today, and let us show you why comfort starts here.
Recent Jobs and Reviews in Riverside, CA
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and trust. Customers consistently praise the company for delivering professional, knowledgeable, and efficient service. A recurring theme is the technical expertise and personable nature of the technicians, who are described as respectful, friendly, and genuinely passionate about their work. Many reviewers highlight the quality of major installations, including complete HVAC system replacements and ductwork, noting impressive speed and precision even under challenging conditions. The company earns strong appreciation for their transparency, thorough documentation, and clear communication about necessary services versus optional ones. Long-term customer loyalty is evident, with clients expressing continued satisfaction over multiple years and repeated service calls. The responsiveness to inquiries and commitment to standing behind their work further reinforces the positive reputation. Overall, the tone is enthusiastic and grateful, with customers feeling valued and confident in the quality and reliability of the service provided.
Riverside, CA at a glance
Cool Air Solutions has completed 25 jobs in Riverside, CA between June 2022 and November 2022.
The most recent job was on November 11, 2022.
Cool Air Solutions has completed 4 jobs in Riverside, CA in the last 12 months. The first job there was in November 2016.
Our Local Reviews by City
- Aguanga, CA (5)
- Aliso Viejo, CA (1)
- Anaheim, CA (5)
- Banning, CA (2)
- Beaumont, CA (5)
- Bonsall, CA (9)
- Buena Park, CA (2)
- Canyon Lake, CA (27)
- Carlsbad, CA (59)
- Carson, CA (1)
- Cathedral City, CA (1)
- Chino, CA (2)
- Chino Hills, CA (4)
- Chula Vista, CA (13)
- Corona, CA (51)
- Del Mar, CA (3)
- Downey, CA (1)
- Eastvale, CA (1)
- El Cajon, CA (8)
- Encinitas, CA (5)
- Escondido, CA (119)
- Fallbrook, CA (65)
- Fontana, CA (2)
- Fountain Valley, CA (2)
- Fullerton, CA (2)
- Garden Grove, CA (5)
- Hacienda Heights, CA (1)
- Hemet, CA (73)
- Homeland, CA (9)
- Huntington Beach, CA (1)
- Irvine, CA (4)
- Jurupa Valley, CA (2)
- La Verne, CA (1)
- Ladera Ranch, CA (1)
- Laguna Hills, CA (5)
- Laguna Niguel, CA (2)
- Laguna Woods, CA (1)
- Lake Elsinore, CA (119)
- Lake Forest, CA (16)
- Lakeside, CA (5)
- Lakewood, CA (1)
- Lemon Grove, CA (1)
- Los Alamitos, CA (1)
- Menifee, CA (203)
- Mission Viejo, CA (8)
- Moreno Valley, CA (26)
- Murrieta, CA (670)
- Newport Beach, CA (1)
- Norco, CA (3)
- Nuevo, CA (2)
- Oceanside, CA (86)
- Ontario, CA (1)
- Pala, CA (1)
- Pauma Valley, CA (7)
- Perris, CA (24)
- Poway, CA (9)
- Ramona, CA (4)
- Rancho Cucamonga, CA (1)
- Rancho Santa Fe, CA (2)
- Rancho Santa Margarita, CA (2)
- Redlands, CA (4)
- Riverside, CA (36)
- San Bernardino, CA (4)
- San Clemente, CA (1)
- San Diego, CA (81)
- San Dimas, CA (1)
- San Jacinto, CA (28)
- San Juan Capistrano, CA (2)
- San Marcos, CA (48)
- Santa Ana, CA (3)
- Santa Fe Springs, CA (1)
- Solana Beach, CA (1)
- Spring Valley, CA (5)
- Sun City, CA (1)
- Temecula, CA (762)
- Temescal Valley, CA (1)
- Trabuco Canyon, CA (3)
- Upland, CA (2)
- Valley Center, CA (18)
- Vista, CA (161)
- Warner Springs, CA (5)
- Wildomar, CA (77)
- Winchester, CA (125)
- Yorba Linda, CA (14)
- Yucaipa, CA (5)
Job Locations and Reviews
Arrived on site to perform diagnostic on unit. Upon arrival, homeowner mentioned another company was out to diagnose, and told him it was a bad heat exchanger. Advised I would have to do my own diagnostic, but homeowner was under the impression that I was only coming out to verify wether the the heat exchanger was good or bad. After speaking with management, it was approved it go ahead and pull the heat exchanger as part of the diagnostic fee, even though there is usually an extra charge for the added labor. Unit has sever roll out burn marks all over the heating compartment. This is usually indication that there is an issue with venting. Per homeowner approval, went ahead and pulled heat exchanger and performed water leak test. Thoroughly inspected all chambers of heat exchanger and it does not appear to be cracked at this time, although there is a very evident crack starting to form at top most chamber. Showed homeowner findings. Put system back together and cycled heating. Shut syst
During my twenty point heating inspection, I started with the thermostat. Giving a call for heating, and going to furnace to start maintenance. Temp rise of 30-60 needed, I got a temp rise of 43. House heats up to designated temperature. I checked out blower motor of any dirt or debris and it’s clean. Replaced air filter for new air filter. Owner had extra one, so just used his. Hot surface igniter not cracked or having white spots. Flame sensor still working good, no need to be cleaned. Ducting done correctly, and all runs intact. Inducer motor is working efficiently. House heats good and ready for winter.
During my twenty point heating inspection, I started with the thermostat. Giving a call for heating, and going to furnace to start maintenance. Temp rise of 25-55needed, I got a temp rise of 40. House heats up to designated temperature. I checked out blower motor of any dirt or debris and it’s clean. Replaced air filter for new air filter. Owner had extra one, so just used his. Hot surface igniter not cracked or having white spots. Flame sensor still working good, no need to be cleaned. Ducting done correctly, and all runs intact. Inducer motor is working efficiently. House heats good and ready for winter. Will call for maintenance agreement when ready.
During my twenty point heating inspection, I started with the thermostat. Giving a call for heating, and going to furnace to start maintenance. Temp rise of 30-60 needed, I got a temp rise of 42. House heats up to designated temperature. I checked out blower motor of any dirt or debris and it’s clean. Replaced air filter for new air filter. Owner gave permission to replace. Hot surface igniter not cracked or having white spots. Flame sensor still working good, no need to be cleaned. Ducting done correctly, and all runs intact. Inducer motor is working efficiently. House heats good and ready for winter.
Upon arrival unit was operational checked furnace amps they were in range, safety switches were functioning properly, condensation line Was clear. Blower wheel was free of oil and debris, temp rise was in range, filter was clean, flame sensor was clean and ohms for hot surfaces igniter was in range. Upon departure unit was operational and heating.
During my twenty point heating inspection, I started with the thermostat. Giving a call for heating, and going to furnace to start maintenance. Temp rise of 30-60needed, I got a temp rise of 55. House heats up to designated temperature. I checked out blower motor of any dirt or debris and it’s clean. Replaced air filter for new air filter. Owner had extra one, so just used his. Hot surface igniter not cracked or having white spots. Flame sensor still working good, no need to be cleaned. Ducting done correctly, and all runs intact. Inducer motor is working efficiently. House heats good and ready for winter.
During my twenty point heating inspection, I started with the thermostat. Giving a call for heating, and going to furnace to start maintenance. Temp rise of 30-60 needed, I got a temp rise of 54. House heats up to designated temperature. I checked out blower motor of any dirt or debris and it’s clean. Air filter was just replaced. Hot surface igniter not cracked or having white spots. Flame sensor still working good, cleaned off sensor. Ducting done correctly, and all runs intact. Inducer motor is working efficiently. House heats good and ready for winter.
Return grill was making a vibrating noise -I tightened screws on grill as they were a little loose, causing a rattling noise -Noise is fixed now
Upon arrival u it was operational. Started at the indoor unit checked amps they were in range blower wheel was free of oil, condensation line was cleared filter was still in good condition. Moved to the out door unit checked amps and secondary control motor they were in range washed unit from the inside out and closed it up upon departure unit was cooling and operational
Residential warranty. Arrived to find no sound audible in master bathroom wall or at sink. Removed some water from system p-trap and re-energize the system to find small gurgling sound coming from the bathroom sink that may become louder the longer the system remains off. Re-leveled primary condensate drain line to allow proper function of the p-trap. Primed condensate line with water and tested at high cooling speed to ensure no sound was heard at sink. Systems operating properly at this time but instructed homeowner to please record the sound and the exact area in a video to send to us if it occurs again and we will come out to reassess.
Upon arrival performed AC tuneup on 5 year old Goodman unit. Temperature split is normal, cleaned and inspected blower compartment. Checked electrical connections. Flushed condensation drain line with .5 gallons of water. Noticed wrong size filter installed, recommended to Shelly to purchase 20 1/4 x 25 3/8 x 5 1/4. Performed deep cleaning of condenser coil fins and external unit. Inspected electrical components and dual secondary motor control and starter look good however the condenser fan motor is drawing 1.4 - 1.5 amps which is higher than the FLA of 1.3. I recommended to Shelly that we replace it but she would like to forego the repair and wait till a later time. Refrigerant temperatures and pressures were normal. Upon departure system is operational.
Arrived on site to inspect unit client stated u it was not running at some point in the day. Called us out. Saw how he would operate thermostat and advised there is a delay setting that’s preventing it from turning on and off back to back. Advised bill and he was not aware and may just not have know how the thermostat operates. He wanted to inspect unit and see it condition. Cycled cooling inspected condenser. Pressure were still in range just holds r-22. Unit is cooling at 20 degrees. Primary stater is burnt up from age and operation. Would recommend replacing. Secondary motor control for compressor was out of range. Second motor control for fan motor was weak and going bad from motor over working unit. Compressor is working hard as unit is from 1999. Advised compressor is on borrowed time. Would recommend compressor booster to help prevent hard start up and prolong as much life as it can out of compressor. No protection inside and out. Inspected indoor unit filter is okay. Drain li
Upon arrival performed AC tune up on 4 year old AC Pro system. Replaced filter with owner-supplied filter. Checked static pressure, temp split was good at 21 degrees. Indoor York furnace did not have a rack for the filter, while the system runs it lets a tremendous amount of unfiltered air to run through the system. To help with this I installed 2 metal tabs to keep the filter held down in place. Performed deep cleaning on exterior unit and condenser coil fins. Condenser fins were very dirty. Refrigerant pressures and temperatures were normal. Dual secondary motor control was slightly weak on the compressor side. Annie and her son Lorenzo mentioned that the kitchen does to receive any cool air, and you can feel warm attic air coming from the register. I inspected the duct work and found them to be in very poor condition. They are coming apart at several joints, I attempted to repair it but there wasn’t enough duct material to join it together. I highly recommend the duc
Arrived on site to perform spring tune up on a 5 year old unit. Client stated no issues. Cooling is good. Cycled on and operational. Washed condenser coil inside and out. Fan motor is good and in range. Primary stater is good. Circuit board are good. Start up and run amps on compressor are good and in range. Checked pressure and found them in range just a bit off. Inspected indoor unit. Filter was okay advised could hold off till the new year and they will be replacing. Blower motor and assembly are good. Drain lines are good at this time. Temperature split is at 17 degrees. Advised due to pressure being a bit low unit is not cooling as great as it should but is cooling home. Advised would want to charge up and recited pressure to see if a leak is present but would recommend adding leak dye and sealant Incase refrigerant is leaking we have something to trace off as this is a process and can take a couple times. Wife is aware and understands but stated she will have to talk it over with
Check System Static Pressures Check all Safety and Limit Switches Clean Condenser Coil Duct Leakage Inspection Remove Debris from the Condenser Check Refrigeration Pressures Perform Visual Inspection and Clean Service Panel Measure Starting Amperage of the Compressor Tighten Electrical Connections Measure System Amperage and Voltage Flush Condensate Drain Lines Measure Temperature Difference Vacuum Furnace Return Air Grille Clean in Place Blower Compartment Inspect Blower Wheel for Proper Balance Monitor Air Purification System Apply UV Protective Coating on Condenser Perform Energy Usage Calculation Test Condenser Pressure Switches Check Thermostat for Proper Operation / Calibration
Arrived on site to diagnose a no cooling unit. Spoke to tenant and he stated unit stopped working and froze over. Since then he stopped using unit. Cycled on and was operational. Inspected unit and condenser. Checked pressure and found unit to hold r-22. Pressure were steady but did show a air flow restriction. Unit is cooling hole just not efficiently. Fan motor is leaking oil from age and operation. Secondary motor control is good. Stater is pitted from age and operation and being original. Start up was very loud and hard. Run amps were high pulling 23 and max rated at 28. Advised compressor is working hard and can face issues in future. Inspected Indoor unit. Found unit to be dirty. Found unit to only have one drain lines and no secondary line or any safety over flow switches to prevent over flow of water. Drain lines are doesn't and are clogged up as no water is being seen draining but can see nigh build up of dirt. Advised when unit froze over and thawed out a lot of water was in
Performed warranty. Homeowner states that unit is making banging noise, believes it is the condensation line inside the wall. Identified it is a banging noise, not gurgling. Noise is most prevalent at night time. Inspected drain in attic as well as underneath sink. Everything seems to be in order. Did notice that condensate line is not strapped and definitely has a lot of play in it. Vibrating from unit could be causing line to move wnd maybe bang inside the wall. Strapped up the line tightly. Homeowner also believes that was the issue. System is operational upon departure.
Performed AC maintenance on 2 York systems. Cycled systems for cooling. Checked indoor systems electrical and components. Temperature splits are in range. Filters are clean. Ductwork and connections are in good condition. Checked outdoor units electrical and system components. Amp draws on right side unit condenser fan motor and compressor are high, and condenser fan motor has started to leak oil significantly. Primary and secondary motor controls in good condition and in range. Pulled condenser motors and thoroughly washed out condenser coils inside and out. Renewed ESA maintenance program, wants to stay on yearly maintenance program. System is fully operational upon departure, homeowner fully aware of findings and recommendations for units.
Upon arrival, performed deep cleaning of condenser coil and surrounding area of external unit. Checked electrical components and refrigerant pressures and all were within limits. Inspected filter and found it to be contaminated with dust, owner said she will order her own and replace it herself. Temperature split in the home was 20 degrees. Upon departure system was operational.
Upon arrival unit was operational. Went up to the roof checked systems amps they were in range. Checked secondary motor controls they were in range. Washed unit . Checked systems pressures they were in rang, and Changed filter. Upon departure unit was operational and cooling.
Arrived on site to diagnose a no cooling 2017 Goodman unit. Spoke to client upon arrival and she stated unit runs but is just not cooling home down. She saw outside is on. Indoor is blowing hot air. Had her cycle is and went to inspect both unit are operational. Inside a was good. Outside fan turned on but sounded like compressor was not. Inspected electrical compartment found secondary motor control really weak and low. Found this was Addressed to her last spring tune up visit but did hold of them. Put new one in to make sure it’s the only issues. Stater is okay starting to show wear. Start up up are in range just sound like compressor is starting up hard. Recommend a compressor booster kit to help prevent hard start up and prolong life of unit. Checked pressure and found pressure good and cooling home. No protection inside and out and advised client unit should have protection. Went over all findings and areas of concerns with client and clips aware of how unit is running and cond
Arrived on site to perform AC diagnostic on year 2000 Lennox condensing unit for upstairs. Upon arrival Robert stated that the upstairs system recently stopped working and is only blowing out hot air. He stayed in about five years ago service was done, they had to add R22 refrigerant charge and a compressor saver kit. Began diagnostic at outdoor unit and found that system was not getting high-voltage power from breaker panel. Found that air conditioning breaker was tripped. Reset switch system still will not turn on due to duel secondary motor control becoming defective. Installed new dual secondary motor control and condenser fired up. I measured amps for a compressor and found that system was overamping and using way too much power from what it was designed for. This is an indication that the compressor is overworking and is the reason why the breaker panel has tripped and will ultimately happen again due to old age and wear and tear. Compressor saver kit that was already inside of t
Upon arrival performed diagnostic on Goodman system we installed. Coils were completely dirty and there was no coil showing at all. Washed coils off. Signed client up with Memebrship. Replaced secondary motor control. Added Hardstart kit to keep amperage’s low on start for compressor. Refrigerant levels & temp splits in range. System is operational upon completion
Upon arrival performed diagnostic on Goodman system we installed. Coils were completely dirty and there was no coil showing at all. Washed coils off. Signed client up with Memebrship. Replaced secondary motor control. Added Hardstart kit to keep amperage’s low on start for compressor. Refrigerant levels & temp splits in range. System is operational upon completion
Upon arrival performed diagnostic on Goodman system we installed. Coils were completely dirty and there was no coil showing at all. Washed coils off. Signed client up with Memebrship. Replaced secondary motor control. Added Hardstart kit to keep amperage’s low on start for compressor. Refrigerant levels & temp splits in range. System is operational upon completion