HVAC and Plumbing Services in Perris with the Strongest Guarantees Around
Homeowners in Perris need systems they can count on—from efficient air conditioners that hold up in the summer heat to reliable plumbing that keeps daily life flowing smoothly. At Cool Air Solutions, we deliver fast, professional HVAC and plumbing services throughout Perris, backed by unbeatable guarantees and more than 8,000 five-star reviews. Whether it’s a small repair or a major installation, our team brings the experience, skill, and care your home deserves.
Need help fast? Schedule your service online or call 951-234-0748 to get started.
Heating and Cooling Services in Perris
A dependable HVAC system isn’t a luxury—it’s essential to your comfort, especially during hot Perris summers and cool desert nights. Our certified technicians are trained to service all major brands and will never upsell or pressure you into something you don’t need. Just expert recommendations, honest pricing, and work that’s built to last.
-
Air conditioner installation, repair, and replacement
-
Electric and gas furnace services
-
Heat pumps and ductless mini-splits
-
Zoned comfort system upgrades
-
Smart thermostat installation
-
Seasonal tune-ups and maintenance checks
-
Ductwork inspections and airflow improvements
Every HVAC system we install comes with our signature guarantees:
- Lifetime Craftsmanship Guarantee
- 1-Year Test Drive Guarantee
- No Surprise Guarantee
- 5 or 10-Year No Lemon Guarantee
And if your system fails and we can’t fix it within 24 hours? You’re covered by our 24-Hour Fix-It Guarantee—we’ll cover the cost of a hotel stay so your family doesn’t have to suffer through the discomfort.
Plumber in Perris, CA
Don’t let leaks, clogs, or cold water disrupt your day. Our licensed plumbers provide comprehensive residential plumbing services throughout Perris. Whether you need a water heater replacement or you’re dealing with a hidden slab leak, we’ll handle the job with precision, cleanliness, and care.
-
Tank and tankless water heater repair and installation
-
Leak detection and slab leak repair
-
Faucet, toilet, and shower fixture services
-
Water softener and filtration system installations
-
Pipe repair and repiping
-
Garbage disposal repair and replacement
-
Sewer camera inspections and drain cleaning
-
Pressure regulation and backflow prevention
We don’t use subcontractors or cut corners. Every plumbing job is completed by a licensed professional and backed by our Lifetime Craftsmanship Guarantee—so you know it’s done right the first time.
Why Homeowners in Perris Choose Cool Air Solutions
There’s a reason so many homeowners in Perris call Cool Air Solutions first. We go beyond the basics, delivering comfort with integrity, consistency, and a customer-first mindset. Here’s what makes us different:
-
We show up on time. Your schedule matters. Our team respects it with fast response times and tight appointment windows.
-
We listen to what you need. No pressure, no upsells—just honest recommendations based on your home, your goals, and your budget.
-
We clean up after ourselves. From floor coverings to shoe covers, we leave your home just as clean as we found it—sometimes cleaner.
-
We don’t stop at “good enough.” We double-check every connection, test every system, and inspect every inch. Because shortcuts aren’t our style.
-
We treat you like family. You’ll always get polite, professional service from background-checked technicians who care.
We believe that delivering comfort means doing things the right way, every single time—and our guarantees prove it.
Book HVAC or Plumbing Services in Perris Today
From emergency repairs to smart system upgrades, Cool Air Solutions is the name homeowners in Perris trust for real comfort and real peace of mind.
Contact us via our online form or call 951-234-0748 to book your HVAC or plumbing service today. Let us show you why comfort really does meet care.
Recent Jobs and Reviews in Perris, CA
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and trust. Customers consistently praise the company for delivering professional, knowledgeable, and efficient service. A recurring theme is the technical expertise and personable nature of the technicians, who are described as respectful, friendly, and genuinely passionate about their work. Many reviewers highlight the quality of major installations, including complete HVAC system replacements and ductwork, noting impressive speed and precision even under challenging conditions. The company earns strong appreciation for their transparency, thorough documentation, and clear communication about necessary services versus optional ones. Long-term customer loyalty is evident, with clients expressing continued satisfaction over multiple years and repeated service calls. The responsiveness to inquiries and commitment to standing behind their work further reinforces the positive reputation. Overall, the tone is enthusiastic and grateful, with customers feeling valued and confident in the quality and reliability of the service provided.
Perris, CA at a glance
Cool Air Solutions has completed 25 jobs in Perris, CA between April 2021 and August 2021.
The most recent job was on August 18, 2021.
Cool Air Solutions has completed 5 jobs in Perris, CA in the last 12 months. The first job there was in November 2016.
Our Local Reviews by City
- Aguanga, CA (5)
- Aliso Viejo, CA (1)
- Anaheim, CA (5)
- Banning, CA (2)
- Beaumont, CA (5)
- Bonsall, CA (9)
- Buena Park, CA (2)
- Canyon Lake, CA (27)
- Carlsbad, CA (59)
- Carson, CA (1)
- Cathedral City, CA (1)
- Chino, CA (2)
- Chino Hills, CA (4)
- Chula Vista, CA (13)
- Corona, CA (51)
- Del Mar, CA (3)
- Downey, CA (1)
- Eastvale, CA (1)
- El Cajon, CA (8)
- Encinitas, CA (5)
- Escondido, CA (119)
- Fallbrook, CA (65)
- Fontana, CA (2)
- Fountain Valley, CA (2)
- Fullerton, CA (2)
- Garden Grove, CA (5)
- Hacienda Heights, CA (1)
- Hemet, CA (73)
- Homeland, CA (9)
- Huntington Beach, CA (1)
- Irvine, CA (4)
- Jurupa Valley, CA (2)
- La Verne, CA (1)
- Ladera Ranch, CA (1)
- Laguna Hills, CA (5)
- Laguna Niguel, CA (2)
- Laguna Woods, CA (1)
- Lake Elsinore, CA (119)
- Lake Forest, CA (16)
- Lakeside, CA (5)
- Lakewood, CA (1)
- Lemon Grove, CA (1)
- Los Alamitos, CA (1)
- Menifee, CA (203)
- Mission Viejo, CA (8)
- Moreno Valley, CA (26)
- Murrieta, CA (670)
- Newport Beach, CA (1)
- Norco, CA (3)
- Nuevo, CA (2)
- Oceanside, CA (86)
- Ontario, CA (1)
- Pala, CA (1)
- Pauma Valley, CA (7)
- Perris, CA (24)
- Poway, CA (9)
- Ramona, CA (4)
- Rancho Cucamonga, CA (1)
- Rancho Santa Fe, CA (2)
- Rancho Santa Margarita, CA (2)
- Redlands, CA (4)
- Riverside, CA (36)
- San Bernardino, CA (4)
- San Clemente, CA (1)
- San Diego, CA (81)
- San Dimas, CA (1)
- San Jacinto, CA (28)
- San Juan Capistrano, CA (2)
- San Marcos, CA (48)
- Santa Ana, CA (3)
- Santa Fe Springs, CA (1)
- Solana Beach, CA (1)
- Spring Valley, CA (5)
- Sun City, CA (1)
- Temecula, CA (762)
- Temescal Valley, CA (1)
- Trabuco Canyon, CA (3)
- Upland, CA (2)
- Valley Center, CA (18)
- Vista, CA (161)
- Warner Springs, CA (5)
- Wildomar, CA (77)
- Winchester, CA (125)
- Yorba Linda, CA (14)
- Yucaipa, CA (5)
Job Locations and Reviews
Arrived on site to perform diagnostic on 14 year old unit. Homeowner states that upstairs system is not cooling. Has not worked for about a month. Cycled system for cooling. Thermostat is extremely finiky and they have to play with it for a while before they can get it to go into the cooling mode. System finally kicked on and indoor unit is blowing air, outdoor unit is not responsive. Checked outdoor unit electrical and system components. Found a bad secondary motor control for both compressor and condenser fan motor that was not allowing the system to turn on. Put in new secondary motor control and cycled system on. Refrigerant pressures are in range and system is producing proper temperature split. Amp draws for compressor and condenser fan motor are within range. Compressor start up amps are high. Unit is operating on r-22 refrigerant. Went over findings and recommendations with homeowner. Went over maintenance program. With approval replaced secondary motor control as well as repla
System was making loud noise due to vibration at the condenser. Installed rubber isolation strips on the metal plate behind the service ports, adjusted the position of the condenser slightly and replaced the plastic locking caps with metal caps to reduce vibration sound.
Arrived on site to diagnose a no cooling 2004 unit. Unit is original to home. Client stated they just moved in and had issues so home warranty referred us to him and he called us out. Upon arrival spoke over with client. He stated he recently noticed home getting warm. But system washer at 66 degrees and only hot air was coming out. He went outside and saw condenser was not spinning and shut it all off. Advised I would evaluate full system. Cycled system and unit did not turn on and made loud buzzing noise. Inspected electrical compartment and found secondary control completely bad and not turning on unit. Replaced to test and evaluate system. Found primary starter original and worn out on pittings. Fan motor is over amping pulling 1.5 amps as it’s max rated at 1.4. Motor could fail In future due to age and condition. checked start up on Compressor and found it way above range as compressor is having a really hard time turning unit on. Run amps is pulling 24-25 amps advised max rate
Inspected the system and the unit is working on arrival, filter is very very dirty. Looking up at the system the coils are pretty dirty and the system probably just needs to be maintained it’s been a year since the unit was installed. The unit is due for its first since install maintenance but the extension ladder needs to be very large as the one I have supplied is too short. Need to return with a taller ladder to perform maintenance.
Replaced failed icomfort thermostat with S30 display and smart hub.
Arrived on site to perform spring tune up on a 2010 trane unit. Condenser located in back yard furnace located in hall closet. Client stated he been on vacation for couple months and just got back. Doesn't use system a lot but just wanted serviced. Washed condenser coil inside and out. Unit was dirty. Primary control was worn out pitted on contact points. Secondary control was completely dead. Unit was only starting due to Compressor booster kit. Would need to be replaced to operate efficiently. Fan motor was operating in range. Found single run secondary control was below range for fan. Compressor start up amps are good and run amps are in range. Checked pressure and are good and cooling home at 23 degrees. Inspected indoor unit found secondary Control really low for blower motor. Recommend replacing before completely fails. Blower is good and filter was dirty and replaced. No protection on indoor unit either. Cycled unit to ensure system operating. Wen rover al findings and repairs
Performed diagnostic on 18 year old York unit. System is not cooling. Homeowner mentioned that we came out here last year and replaced some parts, and unit was working for a bit and then failed a month or so after but never called us back in. Advised that because he didn’t call us out at that time unfortunately there is no longer any warranty on any work performed at the time, given if it is the same issue. Cycled thermostat for cooling, unit is completely unresponsive. Checked for power at indoor unit. Found a bad transformer not giving the unit any low voltage power. Also found a low secondary motor control for indoor motor. Evap coil and blower wheel are extremely dirty. Homeowner is selling the home, so he is only wanting to do what ever is absolutely necessary and is also not interested in replacing the unit. Replaced transformer and secondary motor control. System kicked on. Checked refrigerant pressures and found unit low on refrigerant. System uses r-22 refrigerant, and syste
Summer AC Maintenance Performed. Upon arrival system is working and operational. I began out the outdoor condenser by braking down the unit and cleaning with water and coil solution removing dirt and debris. Inspected all electrical components for wear, tested amp draws on system. Checked and measured refrigerant system pressures and charge. Recommended to member to add surge protection on outdoor unit to protect system, disconnect is fuseless. Proceeded to indoor furnace unit. Inspected electrical components to ensure tightness, inspected board for burns and marring. Inspected blower housing for dust and debris. Checked blow motor control. Inspected ducts for air leakage. Inspected main condensate. Recommend blower wheel cleaning, caked dust on wheel. Recommend cut and clean as main condensate was clear. Performed cut and clear for main condensate. Installed thermostat. Upon departure system is working and operational.
Upon arrival perorm diagnostic. Found issue to be a weak secondary motor. Filter has been replaced. Motor is leaking oil and over amping. High amp draws on start up. Client chose basic repair and membership. System is operational upon departure.
Upon arrival perorm diagnostic. Found issue to be a weak secondary motor. Filter has been replaced. Motor is leaking oil and over amping. High amp draws on start up. Client chose basic repair and membership. System is operational upon departure.
Upon arrival perorm diagnostic. Found issue to be a weak secondary motor. Filter has been replaced. Motor is leaking oil and over amping. High amp draws on start up. Client chose basic repair and membership. System is operational upon departure.
Upon arrival perorm diagnostic. Found issue to be a weak secondary motor. Filter has been replaced. Motor is leaking oil and over amping. High amp draws on start up. Client chose basic repair and membership. System is operational upon departure.
Technician arrived on site and found no power to the unit. Found the breaker had been tripped. Checked the motors to see if anything was grounded. Everything checked out. Coils were restricted from dirt. Lack of maintenance is not covered under warranty. Cleaned coils and inside of the condenser with chemicals and water. Unit is operational upon departure.
After Lennox rebate total $19,000 Correct airflow/comfort issue in the master bedroom and room right next to master. 90 days no interest no payment. Defaults to 120 Months at 6.9% no pre-payment penalties. 0-down $213 per month or GoGreen finance
Upon arrival performed maintenance on carrier system. FOund motor to be leaking excessive amounts of oil, Brought client out to system and showed her what is going on, Client declined repairs, they have friend who does HVAC and will replace for them. Secondary motor control is borderline of being out of range. Start up amps are beginning to rise. Refrigerant levels are in range. DID not REplace filter did not have in stock. Cleaned furnace caging. Blower wheel is very dirty and needs advanced cleanings. System was reset tested and fully functional upon departure.
Upon arrival performed maintenance on carrier system. FOund motor to be leaking excessive amounts of oil, Brought client out to system and showed her what is going on, Client declined repairs, they have friend who does HVAC and will replace for them. Secondary motor control is borderline of being out of range. Start up amps are beginning to rise. Refrigerant levels are in range. DID not REplace filter did not have in stock. Cleaned furnace caging. Blower wheel is very dirty and needs advanced cleanings. System was reset tested and fully functional upon departure.
Upon arrival performed maintenance on carrier system. FOund motor to be leaking excessive amounts of oil, Brought client out to system and showed her what is going on, Client declined repairs, they have friend who does HVAC and will replace for them. Secondary motor control is borderline of being out of range. Start up amps are beginning to rise. Refrigerant levels are in range. DID not REplace filter did not have in stock. Cleaned furnace caging. Blower wheel is very dirty and needs advanced cleanings. System was reset tested and fully functional upon departure.
Upon arrival performed maintenance on carrier system. FOund motor to be leaking excessive amounts of oil, Brought client out to system and showed her what is going on, Client declined repairs, they have friend who does HVAC and will replace for them. Secondary motor control is borderline of being out of range. Start up amps are beginning to rise. Refrigerant levels are in range. DID not REplace filter did not have in stock. Cleaned furnace caging. Blower wheel is very dirty and needs advanced cleanings. System was reset tested and fully functional upon departure.
Upon arrival performed diagnostic, System is in pretty bad condition, system has no filters at all. Thermostat batteries were low causing system not to kick on. BReaker was tripped.
Upon arrival performed diagnostic, System is in pretty bad condition, system has no filters at all. Thermostat batteries were low causing system not to kick on. BReaker was tripped.
Upon arrival performed diagnostic, System is in pretty bad condition, system has no filters at all. Thermostat batteries were low causing system not to kick on. BReaker was tripped.
Upon arrival performed diagnostic, System is in pretty bad condition, system has no filters at all. Thermostat batteries were low causing system not to kick on. BReaker was tripped.
Performed AC diagnostic on 2014 carrier system. Upon my diagnostic client stated that nest was displaying Y wire connection issue. Started off by jumping out thermostat wire is directly at thermostat and wires immediately sparked when this happened. Also try to jump it out directly at the circuit board and the fuse instantly popped. Isolated condenser wires coming from outside and try to jump system out again infuse would not pop any more. This led me to the outdoor contactor and found that the low-voltage coil has gone bad which is the reason why the fuse in the attic keeps popping. Also during my inspection I found at the duel secondary motor control has become weak on the fan sideterminal due to the condenser fan motor leaking oil from the bearing And using more power than needed. Informed Chris what is going on with the system and presented him repair options for a long-term solution. He authorized of the best repairs done. Also sign him up on maintenance plan for two visits a year
Arrived on site to perform maintenance on carrier system. System Has never had a maintenance done, it cools but she feels like it takes long sometimes. Cycled system for cooling. Checked indoor and outdoor unit electrical and system components. Unit was not providing proper temperature split initially. Found a super restricted filter, had not been changed out for a couple years. Replaced filter. Also upon inspecting supply registers every single supply register had a cloth filter looking thing inside of them that was completely cutting off air flow and causing refrigerant pressures to be out of wack and system not producing proper temperature. Homeowner had hip surgery and can’t go up a ladder, did not know that the registers were covered. Opened every supply register and removed cover from inside of them. System now has extremely better airflow throughout the whole home. Refrigerant pressures dropped down to normal and system is now producing proper temperature split and cooling ef
Performed AC maintenance on 11 year old unit. Cycled system for cooling. Checked indoor unit electrical and system components. Refrigerant levels are in range and system is producing proper temperature split and cooling correctly. Checked outdoor unit electrical and system components. Pulled condenser motor and thoroughly washed out condenser coil inside and out. Ran system through point inspection. Concerns are as follows: 1. Indoor condensation lines do not have condensation switches to prevent water over flowing. Homeowner mentioned that her secondary line had been dripping but a couple days ago they cleared the lines from the master bedroom, which is where the drain lines are routed. I always performed a basic drain line clear up in attic, but problem could be a little more severe and would need a drain line cut and clear. 2. Furnace is sitting on wooden 2x4’s. 3. Outdoor unit primary motor control is starting to burn and pit up at the contact point. 4. Secondary motor control f