Full-Service HVAC and Plumbing in Menifee Backed by Real Guarantees
When your home needs heating, cooling, or plumbing help, Cool Air Solutions delivers dependable service with no shortcuts and no surprises. From AC tune-ups and new furnace installations to water heater repairs and leak detection, we provide expert care for every comfort system in your home. Homeowners in Menifee count on us for fast, clean, and honest service, always backed by our unbeatable guarantees.
Need service now? Reach out online or call 951-234-0748 to schedule HVAC or plumbing in Menifee today.
Heating and Cooling Experts in Menifee
We handle all things HVAC with precision and care. Whether you're upgrading to a new energy-efficient AC or your furnace isn’t keeping up, our licensed technicians bring the right tools, the right attitude, and rock-solid craftsmanship to every visit.
- AC installation, repair, and maintenance
- High-efficiency furnace and electric furnace installation
- Ductless mini-splits and zoning systems
- Smart thermostat upgrades
- Seasonal system checkups
- Air balancing and airflow improvements
Every installation comes with our full lineup of guarantees—including our Lifetime Craftsmanship Guarantee, 1-Year Test Drive, No Lemon Guarantee, and No Surprise Pricing. And if your system breaks down unexpectedly, you’re covered by our 24-Hour Fix-It Guarantee—or we pay for your hotel stay.
Licensed Plumber in Menifee, CA
Got a leak, clog, or outdated water heater? Our expert plumbing team is ready to help. We specialize in clean, efficient repairs and system replacements that restore your water flow and peace of mind.
- Water heater repair and replacement (standard and tankless)
- Slab leak detection and pipe repair
- Faucet, shower, and toilet service
- Water softeners and filtration systems
- Pressure regulators and backflow prevention
- Garbage disposals, valves, and fixtures
- Camera inspections and sewer cleaning
Our plumbers show up on time, respect your home, and deliver top-tier results backed by our Lifetime Craftsmanship Guarantee—no cut corners, no compromises.
Affordable Options with Five-Star Results
Cool Air Solutions has earned more than 8,000 five-star reviews by putting homeowners first. We offer honest pricing, flexible financing, and a Comfort Club membership to keep your systems running strong year-round.
- Flat-rate pricing with no hidden fees
- Multiple financing options are available
- Exclusive rebates and energy incentives
- Maintenance plans for better performance and fewer breakdowns
- Licensed, insured, background-checked technicians
From energy-efficient upgrades to emergency repairs, you can count on us to get the job done right—and stand behind it.
Schedule Service in Menifee Today
Experience better comfort, better service, and unbeatable protection on every HVAC and plumbing job in Menifee. Use our online form or call 951-234-0748 to book your appointment now—we’ll be there when you need us.
Recent Jobs and Reviews in Menifee, CA
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and trust. Customers consistently praise the company for delivering professional, knowledgeable, and efficient service. A recurring theme is the technical expertise and personable nature of the technicians, who are described as respectful, friendly, and genuinely passionate about their work. Many reviewers highlight the quality of major installations, including complete HVAC system replacements and ductwork, noting impressive speed and precision even under challenging conditions. The company earns strong appreciation for their transparency, thorough documentation, and clear communication about necessary services versus optional ones. Long-term customer loyalty is evident, with clients expressing continued satisfaction over multiple years and repeated service calls. The responsiveness to inquiries and commitment to standing behind their work further reinforces the positive reputation. Overall, the tone is enthusiastic and grateful, with customers feeling valued and confident in the quality and reliability of the service provided.
Menifee, CA at a glance
Cool Air Solutions has completed 25 jobs in Menifee, CA between July 2020 and August 2020.
The most recent job was on August 10, 2020.
Cool Air Solutions has completed 17 jobs in Menifee, CA in the last 12 months. The first job there was in November 2016.
Our Local Reviews by City
- Aguanga, CA (5)
- Aliso Viejo, CA (1)
- Anaheim, CA (5)
- Banning, CA (2)
- Beaumont, CA (5)
- Bonsall, CA (9)
- Buena Park, CA (2)
- Canyon Lake, CA (27)
- Carlsbad, CA (59)
- Carson, CA (1)
- Cathedral City, CA (1)
- Chino, CA (2)
- Chino Hills, CA (4)
- Chula Vista, CA (13)
- Corona, CA (51)
- Del Mar, CA (3)
- Downey, CA (1)
- Eastvale, CA (1)
- El Cajon, CA (8)
- Encinitas, CA (5)
- Escondido, CA (119)
- Fallbrook, CA (65)
- Fontana, CA (2)
- Fountain Valley, CA (2)
- Fullerton, CA (2)
- Garden Grove, CA (5)
- Hacienda Heights, CA (1)
- Hemet, CA (73)
- Homeland, CA (9)
- Huntington Beach, CA (1)
- Irvine, CA (4)
- Jurupa Valley, CA (2)
- La Verne, CA (1)
- Ladera Ranch, CA (1)
- Laguna Hills, CA (5)
- Laguna Niguel, CA (2)
- Laguna Woods, CA (1)
- Lake Elsinore, CA (119)
- Lake Forest, CA (16)
- Lakeside, CA (5)
- Lakewood, CA (1)
- Lemon Grove, CA (1)
- Los Alamitos, CA (1)
- Menifee, CA (203)
- Mission Viejo, CA (8)
- Moreno Valley, CA (26)
- Murrieta, CA (670)
- Newport Beach, CA (1)
- Norco, CA (3)
- Nuevo, CA (2)
- Oceanside, CA (86)
- Ontario, CA (1)
- Pala, CA (1)
- Pauma Valley, CA (7)
- Perris, CA (24)
- Poway, CA (9)
- Ramona, CA (4)
- Rancho Cucamonga, CA (1)
- Rancho Santa Fe, CA (2)
- Rancho Santa Margarita, CA (2)
- Redlands, CA (4)
- Riverside, CA (36)
- San Bernardino, CA (4)
- San Clemente, CA (1)
- San Diego, CA (81)
- San Dimas, CA (1)
- San Jacinto, CA (28)
- San Juan Capistrano, CA (2)
- San Marcos, CA (48)
- Santa Ana, CA (3)
- Santa Fe Springs, CA (1)
- Solana Beach, CA (1)
- Spring Valley, CA (5)
- Sun City, CA (1)
- Temecula, CA (762)
- Temescal Valley, CA (1)
- Trabuco Canyon, CA (3)
- Upland, CA (2)
- Valley Center, CA (18)
- Vista, CA (161)
- Warner Springs, CA (5)
- Wildomar, CA (77)
- Winchester, CA (125)
- Yorba Linda, CA (14)
- Yucaipa, CA (5)
Job Locations and Reviews
Upon arrival performed maintenance. Outdoor condenser fan motor in good condition. Amperages throughtout system very good. Refrigerant levels very good. Had some insulation left over in van and re wrapped customer line set, as dogs chewed it up. System was completely opened up and washed inside and out of coils and inside caging. Replaced 2 20x30 filters. System is operational upon departure.
Upon arrival performed maintenance. Outdoor condenser fan motor in good condition. Amperages throughtout system very good. Refrigerant levels very good. Had some insulation left over in van and re wrapped customer line set, as dogs chewed it up. System was completely opened up and washed inside and out of coils and inside caging. Replaced 2 20x30 filters. System is operational upon departure.
Upon arrival performed maintenance. Outdoor condenser fan motor in good condition. Amperages throughtout system very good. Refrigerant levels very good. Had some insulation left over in van and re wrapped customer line set, as dogs chewed it up. System was completely opened up and washed inside and out of coils and inside caging. Replaced 2 20x30 filters. System is operational upon departure.
Also includes re insulating linset at ac and coil. This will be an el16 instead of a an ml14
Performed diagnostic on 2012 Carrier system. Homeowner stated that system is not cooling. It blows air but it is not cold. Cycled system for cooling. Indoor unit kicks on. Outdoor condenser fan motor is kicking on, but compressor is unresponsive. Checked unit electrical and system components. System is recieving low voltage command as well as high voltage, but compressor is not kicking on. Found a bad secondary motor control on compressor side. Also found a very burned and pitted primary motor control. This system is a single stage unit zoned off into two zones, which is not properly designed and should not be set up in this manner as this causes excess wear and tear on unit. Recommended adding compressor start kit to unit as it kicks on more times in a day than a normal unit would and to prevent some stress on compressor start up. Went over findings and recommendations with homeowners daughter. With homeowner approval, went ahead and replaced primary and secondary motor controls. Cycl
system not cooling. Condenser not coming on.
system not cooling. Condenser not coming on.
system not cooling. Condenser not coming on.
system not cooling. Condenser not coming on.
Performed diagnostic on 2007 Goodman system. Homeowner states system is not cooling. Said they heard a loud bang and it stopped working ever since, hasn’t been working in over a month. Cycled system for cooling. Indoor unit kicks on and is blowing air. Outdoor unit is kicking on, but only the condenser fan motor. Compressor is unresponsive. Checked system electrical and components. Found a bad secondary motor control which was not allowing the compressor to kick on. Primary motor control also has some pretty bad burning and pitting at contact points. Put in a temporary secondary motor control and tested system. Compressor and condenser fan motor are operating within range. System is operating on r-22 refrigerant, which has been phased out at the beginning of this year and is more expensive. Went over findings and and recommendations with homeowner. He approved to go ahead and repair the primary and secondary motor control. Replaced primary and secondary motor controls. Cycled system
Found system non operational upon arrival. Customer stated unit was blowing warm air. Upon inspection found both fuses blown. Checked circuit breaker and tried to reset it. Breaker would not reset and is stuck. Customer stated he had heard the compressor making loud noises in the last couple of days. Checked compressor windings and did find the compressor shorted or grounded. Winding resistance was weak for start winding. Capacitor was reading well within range. Gave customer some options on repairs but I do not recommend them due the condition of the equipment. Customer went over replacement options with comfort advisor. They are thinking it over night and will contact comfort advisor in the morning. Unit non operational upon departure.
Performed AC maintenance on seven-year-old Trane condensing unit. Paul my maintenance there were a few points and concerns that were addressed 3.5 ton Trane- 1. Found that systems refrigerant charge was very low added in about 2 pounds 2. Recommended putting in leak dye To pinpoint location of refrigerant leak 3. If system becomes low again on 410 a charge leak dye must be added.
Performed AC maintenance on 12-year-old Goodman condensing unit. Upon my maintenance I came across a few points and concerns that were addressed. 5 ton GOODMAN- 1. Found that 410 a refrigerant charge appears to be overcharged causing high pressure to shoot above rated psi. 2. System may also contain restriction in TXV if system has refrigerant recovered out and pressures remain the same. 3. Found that condenser fan motor was completely rusted in over amp in at 1.5 4. Compressor also pulling extremely high amps from what it is rated it may cause compressor use much more energy and put it in a higher risk of failing. 5. Compressor pulled about 118 A on lock rotor start up this is a very hard start up and recommend that a compressor saver kit is added to reduce the start up amperage. 6. Static pressure on indoor ductwork and system showing a total of 0.83 which is very high this is due to an undersized return vent. 7. Starter on system which axis breaks showing signs of pitting on contact
Unlit you’re control check
Repaired pinhole leak at the evaporator suction line. Leak tested, vacuumed and recharged system.
Performed diagnostic on system. I was out here about a month and half ago and performed a cut and clear on system due to it being clogged and water was going out the secondary line out the house. Homeowner stated that the system started doing the same thing again and water is going out the side of the house. Drain line is clogged once again and needs to be cleared. Also, homeowner keeps the home at 72 degrees, meaning system runs a little longer and produces more water. Drain line is not set up all the way correctly, needs a p trap closer to evap coil. Homeowner is currently not on the position to take care of any of the repairs. Spoke to Andrew and decided to take care of cut and clear at no cost for this one time only to get system operating as it should. Cut and cleared drain line, was fairly dirty. Also cleaned trap at the bottom of the sink. Condensation is now draining down primary again. System operational upon departure.
Arrived on site to diagnose a leaking system. Upon arrival spoke over with client and had her show me unit. She advised just yesterday u it starting leaking water and randomly indoor unit would make Loud noise. Inspected indoor unit checked electrical compartment and connections. Checked blower wheel and motor. Checked evaporator coil and drain lines. Advised the summary of finds are as followed. Furnace 1. Water spots from water leaking. 2. Filter is wet and slight dirty. 3. Blower assembly is dirty creating stress and causing motor to over work. 4. Blower motor is leaking a lot of oil and has a thick layer of dirt and oil build up. 5. Motor is above max on start up and run amps is at 5 amp and almost at max on while running as it’s shows it’s on it was out. 6. Secondary motor control is bad and reason for loud noise as blower motor was struggling to turn on but couldn’t. 7. Heat exchanger has a lot of heat impingement. 8. Evaporator coil is dirty and has build up of dir
filter drop off
filter drop off
filter drop off
filter drop off
Arrived on site to diagnose a no cooling system. Condenser located in back yard, furnace and evaporator coil located in attic. Upon arrival had client show me u it and found the disconnect to Ac unit was pulled out and the house. Spoke over with client he stated he had a friend replace a component that went bad in past And unit was working fine since last summer and since January of this year the unit started not operating. Client did his own diagnostic and checked breaker switches and what he could And since then he stated his wife would have to turn Thermostat on and then him Turn the system on from the disconnect breaker and unit would turn on but just recently it didnt work any more and unit is making Loud buzzing noise when disconnect is in. Found indoor unit operational. Checked condenser unit. Checked electrical compartment and components. Found primary control completely burnt and pitted in and component was burnt and stuck in. Found secondary control completely dead and both
Tested system on cooling mode. Replaced filters. Measured indoor temperatures. Measured outdoor electrical components. Inspected fan motor. Verified refrigerant charge. Checked fuses. Cleaned inside of condenser and washed coils.
2803 deposit paid by cc and balance of 15000 paid by service finance
Upon arrival performed maintenance. Outdoor systems were opened up and washed out. Coils are very clean. Secondary motor controls are in good condition. Primary power distributor good. Refrigerant levels good. Amperages on compressor 8 amps running. Bigger unit start amps 5.66, smaller unit start amps 28.8. Filters were replaced. Fan moto amp draws very good. Constant 5-6 amp draws on indoor blower motors. Blower wheels are good and clean. Circuit board and electrical connections in good condition. System was reset tested and fully functional upon departure,