Full-Service HVAC and Plumbing in Menifee Backed by Real Guarantees
When your home needs heating, cooling, or plumbing help, Cool Air Solutions delivers dependable service with no shortcuts and no surprises. From AC tune-ups and new furnace installations to water heater repairs and leak detection, we provide expert care for every comfort system in your home. Homeowners in Menifee count on us for fast, clean, and honest service, always backed by our unbeatable guarantees.
Need service now? Reach out online or call 951-234-0748 to schedule HVAC or plumbing in Menifee today.
Heating and Cooling Experts in Menifee
We handle all things HVAC with precision and care. Whether you're upgrading to a new energy-efficient AC or your furnace isn’t keeping up, our licensed technicians bring the right tools, the right attitude, and rock-solid craftsmanship to every visit.
- AC installation, repair, and maintenance
- High-efficiency furnace and electric furnace installation
- Ductless mini-splits and zoning systems
- Smart thermostat upgrades
- Seasonal system checkups
- Air balancing and airflow improvements
Every installation comes with our full lineup of guarantees—including our Lifetime Craftsmanship Guarantee, 1-Year Test Drive, No Lemon Guarantee, and No Surprise Pricing. And if your system breaks down unexpectedly, you’re covered by our 24-Hour Fix-It Guarantee—or we pay for your hotel stay.
Licensed Plumber in Menifee, CA
Got a leak, clog, or outdated water heater? Our expert plumbing team is ready to help. We specialize in clean, efficient repairs and system replacements that restore your water flow and peace of mind.
- Water heater repair and replacement (standard and tankless)
- Slab leak detection and pipe repair
- Faucet, shower, and toilet service
- Water softeners and filtration systems
- Pressure regulators and backflow prevention
- Garbage disposals, valves, and fixtures
- Camera inspections and sewer cleaning
Our plumbers show up on time, respect your home, and deliver top-tier results backed by our Lifetime Craftsmanship Guarantee—no cut corners, no compromises.
Affordable Options with Five-Star Results
Cool Air Solutions has earned more than 8,000 five-star reviews by putting homeowners first. We offer honest pricing, flexible financing, and a Comfort Club membership to keep your systems running strong year-round.
- Flat-rate pricing with no hidden fees
- Multiple financing options are available
- Exclusive rebates and energy incentives
- Maintenance plans for better performance and fewer breakdowns
- Licensed, insured, background-checked technicians
From energy-efficient upgrades to emergency repairs, you can count on us to get the job done right—and stand behind it.
Schedule Service in Menifee Today
Experience better comfort, better service, and unbeatable protection on every HVAC and plumbing job in Menifee. Use our online form or call 951-234-0748 to book your appointment now—we’ll be there when you need us.
Recent Jobs and Reviews in Menifee, CA
Customers say: The overall sentiment expressed across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and trust. Customers consistently praise the company for delivering professional, knowledgeable, and efficient service. A recurring theme is the technical expertise and personable nature of the technicians, who are described as respectful, friendly, and genuinely passionate about their work. Many reviewers highlight the quality of major installations, including complete HVAC system replacements and ductwork, noting impressive speed and precision even under challenging conditions. The company earns strong appreciation for their transparency, thorough documentation, and clear communication about necessary services versus optional ones. Long-term customer loyalty is evident, with clients expressing continued satisfaction over multiple years and repeated service calls. The responsiveness to inquiries and commitment to standing behind their work further reinforces the positive reputation. Overall, the tone is enthusiastic and grateful, with customers feeling valued and confident in the quality and reliability of the service provided.
Menifee, CA at a glance
Cool Air Solutions has completed 25 jobs in Menifee, CA between August 2021 and September 2021.
The most recent job was on September 8, 2021.
Cool Air Solutions has completed 17 jobs in Menifee, CA in the last 12 months. The first job there was in November 2016.
Our Local Reviews by City
- Aguanga, CA (5)
- Aliso Viejo, CA (1)
- Anaheim, CA (5)
- Banning, CA (2)
- Beaumont, CA (5)
- Bonsall, CA (9)
- Buena Park, CA (2)
- Canyon Lake, CA (27)
- Carlsbad, CA (59)
- Carson, CA (1)
- Cathedral City, CA (1)
- Chino, CA (2)
- Chino Hills, CA (4)
- Chula Vista, CA (13)
- Corona, CA (51)
- Del Mar, CA (3)
- Downey, CA (1)
- Eastvale, CA (1)
- El Cajon, CA (8)
- Encinitas, CA (5)
- Escondido, CA (119)
- Fallbrook, CA (65)
- Fontana, CA (2)
- Fountain Valley, CA (2)
- Fullerton, CA (2)
- Garden Grove, CA (5)
- Hacienda Heights, CA (1)
- Hemet, CA (73)
- Homeland, CA (9)
- Huntington Beach, CA (1)
- Irvine, CA (4)
- Jurupa Valley, CA (2)
- La Verne, CA (1)
- Ladera Ranch, CA (1)
- Laguna Hills, CA (5)
- Laguna Niguel, CA (2)
- Laguna Woods, CA (1)
- Lake Elsinore, CA (119)
- Lake Forest, CA (16)
- Lakeside, CA (5)
- Lakewood, CA (1)
- Lemon Grove, CA (1)
- Los Alamitos, CA (1)
- Menifee, CA (203)
- Mission Viejo, CA (8)
- Moreno Valley, CA (26)
- Murrieta, CA (670)
- Newport Beach, CA (1)
- Norco, CA (3)
- Nuevo, CA (2)
- Oceanside, CA (86)
- Ontario, CA (1)
- Pala, CA (1)
- Pauma Valley, CA (7)
- Perris, CA (24)
- Poway, CA (9)
- Ramona, CA (4)
- Rancho Cucamonga, CA (1)
- Rancho Santa Fe, CA (2)
- Rancho Santa Margarita, CA (2)
- Redlands, CA (4)
- Riverside, CA (36)
- San Bernardino, CA (4)
- San Clemente, CA (1)
- San Diego, CA (81)
- San Dimas, CA (1)
- San Jacinto, CA (28)
- San Juan Capistrano, CA (2)
- San Marcos, CA (48)
- Santa Ana, CA (3)
- Santa Fe Springs, CA (1)
- Solana Beach, CA (1)
- Spring Valley, CA (5)
- Sun City, CA (1)
- Temecula, CA (762)
- Temescal Valley, CA (1)
- Trabuco Canyon, CA (3)
- Upland, CA (2)
- Valley Center, CA (18)
- Vista, CA (161)
- Warner Springs, CA (5)
- Wildomar, CA (77)
- Winchester, CA (125)
- Yorba Linda, CA (14)
- Yucaipa, CA (5)
Job Locations and Reviews
Upon arrival performed diagnostic, found refrigerant levels to be completely flat. House has just been getting hotter and hotter. System is from 1994. Spoke to lluly (daughter ) doesn’t wanna put money into that type of system wants more options for replacing. Scheduled today between 3-5 to have someone come out.
Upon arrival performed diagnostic, found refrigerant levels to be completely flat. House has just been getting hotter and hotter. System is from 1994. Spoke to lluly (daughter ) doesn’t wanna put money into that type of system wants more options for replacing. Scheduled today between 3-5 to have someone come out.
Arrived on site to diagnose a no cooling 2013 unit. Condenser in back yard. Client stated recently unit started making a buzzing noise and call us out. Unit blower warm air out. Inspected electrical found secondary motor control completely bad. Replaced to evaluate full system. Fan motor is covered from oil leaking in past. Motor over amping pulling 1.7 rated for 1.4. Advised motor is on its way out and can fail at any time. Primary starter is original and worn out on contact points from operation. Checked start up and are in range but recommended adding a compressor booster kits to help prevent hard start up and prolong life of compressor. Run amps good pulling 9 and max at 15. Pressures are good and in range and cooling. No protection on unit. Went over all findings and areas of concerns and recommendations. Client is aware how unit is running and repairs and recommendations needed. Client did want to go forward with the minimum repairs of a secondary control and sign up for ESA. In
Arrived on site to diagnose a no cooling 2005 unit. Client stated he lived in home for a year. Recently unit stopped cooling and is blowing hot air out. Cycled unit. Found thermostat hanging and not secured to wall. Advised not good cause could get knocked off and could crate a low voltage. Recommend replacing. Furnace is closed up and skewed up and not accessible so could not look or work on unit. Out door unit operational checked all electrical compartment components. Found primary starter is worn out and burnt up. Secondary motor control is good. Circuit board good but no protection on unit. Advised unit smell a lot like pee and is not good if it is happening. Checked refrigerant pressure and found unit is really low on pressure and almost flat. Advised client of findings and he is aware of findings and repairs needed. Client stated he signed up for home warranty recently and he is gunna wait and see why they can do as he did not expect repairs and possibility of issues that is happ
Preformed system diagnostic on Lennox unit. Upon arrival client was in contact with Lennox and thinks the smart hub is defective. I found that the smart is defective due to it not being able to find WiFi router. System is still operational but keeps sending error for the WAC. Installed new PCO kit supplied by client. Installed 2 surge protector for indoor and out door units. Will be returning with smart hub what part is in stock. Upon departure system is cooling
Rewired customer supplied thermostat. Cycled system through modes. System is operational upon completion.
Performed AC maintenance on 28-year-old comfortmaker Condenser. Arrived at tenants house and client states that system is running good and She uses it very little. 1. System Contained R22 refrigerant which was completely phased out January 1, 2020 2. Refrigerant pressure seems slightly low, but system is Cooling with a good temperature split at the moment 3. Compressor amps we’re at 11 you’re not showing any signs of high power usage at the moment 4. Duel secondary motor controls is in range on hermetic side terminal 5. Started showed signs of pitting and burn marks on contact points 6. Filter needs to be swapped in the beginning of the winter 7. Primary drain line is flowing properly at this time and shows no sign of clog Performed full maintenance on system And cleaned condenser coil’s off. Tenant states that she rarely use the system and will swap the filter out towards the winter. System is at 28 years old and should be watched closely for every summer and winter. At this tim
Upon arrival performed thermostat install, client did not want to do membership at this time, will call us if they decide. Gonna talk over with wife .
Upon arrival performed thermostat install, client did not want to do membership at this time, will call us if they decide. Gonna talk over with wife .
Upon arrival performed thermostat install, client did not want to do membership at this time, will call us if they decide. Gonna talk over with wife .
Upon arrival performed thermostat install, client did not want to do membership at this time, will call us if they decide. Gonna talk over with wife .
Performed AC maintenance on a Lennox condenser. Cooling temperature split is 22 degrees. Condensate lines are clear. UV light is good. Filter is very dirty and changed today. Indoor amp draws are in range. Outdoor coils were very dirty. This is creating a huge air blockage preventing normal operation of the unit and decreasing efficiency. They were chemically cleaned today. Refrigerant pressures are verified in range. Battery cap is out of range on the compressor terminal. This piece was warrantied today. Compressor start and run amps are ok. System was running at end of appointment. Continued maintenance for this system is highly recommended due to the condition of the outdoor unit. Customer paid for today’s visit via telephone
Found small piece of insulation tape inside of the condenser which was making noise during operation, removed the tape. The noise when after the system turns off is refrigerant inside the coils equalizing. This is normal operation and normally unnoticeable depending on the area the system is located in.
Inspected the bedroom duct for flapping noise. There was no noise during operation of the fan or the Ac. Opened the register to inspect the inside of the duct and pushed the duct up a little to remove some slack and hopefully stop the noise. Tested system and still no sound.
Summer AC Maintenance Performed Upon arrival system is working and operational. I began my maintenance at the outdoor condenser by breaking it down and cleaning with water and coil solution, removing dirt and debris. I inspected electrical components for wear and tight connections. I checked refrigerant pressures and charge. I tested system amperages. I then proceeded to the indoor furnace unit. I measured temperature splits. I checked condensates for proper drainage and safety. Filter was changed. Inspected electrical to ensure tight connections and monitor wear. Inspected blower compartment for dust and dirt as well as proper balance. Upon inspection of the indoor furnace unit I found the secondary motor control to be well below its rated values, this is due to the high amount of dirt and dust in the furnace and blower scroll wheel, recommend motor control be replaced as well as the blower housing and furnace be cleaned. Upon departure system is working and operational.
Upon arrival performed diagnostic, issue was part that I checked last time and recommended on tune up. Client understood completely. System is operational upon departure.
Upon arrival performed diagnostic, issue was part that I checked last time and recommended on tune up. Client understood completely. System is operational upon departure.
Upon arrival performed diagnostic, issue was part that I checked last time and recommended on tune up. Client understood completely. System is operational upon departure.
Upon arrival performed diagnostic, issue was part that I checked last time and recommended on tune up. Client understood completely. System is operational upon departure.
Job walk
Performed AC maintenance on a Trane condenser. Units cooling temperature split is 20 degrees. Unit is equipped with a merv rack, Merv 16 filter is clean. Indoor amp draws are good. Outdoor unit was chemically washed. Compressor bay and service panel was cleaned. Refrigerant charge was verified in range. Start component is out of range and was replaced today. Starter is ok at this visit. High voltsge disconnect has no fuses causing system to be unprotected. Surge protection was installed today to protect the outdoor unit. System was running at end of appointment.
Preformed diagnostic on 2008 Goodman condensing unit. Upon arrival homeowner states that he recently swapped out his thermostat with a brand new one called the Sensi. He noticed after he put the thermostat on it did not work. After trouble shooting there were multiple points of concerns and issues found with the system. 3.5 ton condenser- 1. Duel secondary motor control was defective on hermetic and fan side terminal. This may have been caused by the compressor using too much power which ultimately caused extra strain to this component causing it to become defective 2. Compressor is pulling 16 A which is incredibly high considering the max is rated for 18 3. System Contains R22 refrigerant which was phased out January 1, 2020 4. Evaporator coil was not equipped with secondary float switch in the case of the lines ever backing up this would end up preventing a flood over 5. Filter was wrong size and needs to be swapped out every 1 to 3 months 6. Outdoor condensing coil was plugged up w
Quality control check
Performed AC maintenance on a Goodman condenser. Units cooling temperature split is over 25 degrees. Condensate lines are clear. Duct runs are sealed. Indoor blower motor is leaking oil. Start component is also leaking but is still in range. Burn marks on the control board. Outdoor unit was chemically cleaned. Compressor bay and service panel was cleaned. Start component is out of range by a lot on the compressor side. Starter is burned up. I am recommending replacement on these parts. Refrigerant charge was verified ok. Customer is aware of the condition of his system. He was given options but he said his wife handles this situation and will be calling today to move forward. System was running at end of appointment.
Performed AC maintenance on a pair of Carrier units. Customer reported room temperature air coming from the down stairs unit. Verified the system was low on refrigerant. I added 3 pounds of refrigerant. Performed a bubble test with no results, I added leak dye in order to further solve this issue. After refrigerant was added cooling went up and customer was happy. Condensate lines are clear but have no safety switch. Duct runs are sealed. Indoor amp draws are good at thus time. Upstairs unit was cooling over 20 degrees, amp draws are in range. Condensate lines are clear. Customer has been changing filters in a timely manner. Outdoor units were chemically washed. Service panels and compressor bays were cleaned. Systems are not electrically protected. Start components are in range at thus time. Compressor and fan amp readings are ok. A return visit to further solve the leak issue will be scheduled.